Skip to main content
Pay nowView my order
Visit the APC store

APC Back-UPS BE650G2-FR Off-Line UPS - 400 Watts / 650 VA - 8 FR outlets + 1 USB

Six outlets out of eight stay powered by the battery, the other two filter surges. 10 minutes of runtime at half load, a lit status display and a full recharge in 6 hours.

  • Runtime 10 minutes at 50% load (200 W), 5 minutes at 70% (280 W)
  • 6 battery-backed outlets and 2 surge-protected outlets
  • USB charging port for mobile devices
  • Lit display: operating, battery mode, battery to replace, overload
  • Data line protection: RJ45 telephone and RJ45 Ethernet network
  • Surge absorption 310 joules
  • Wall circuit wiring fault indicator
  • Adjustable voltage sensitivity for unstable supplies and generators
  • Periodic battery self-test
  • Full recharge in 6 hours
  • Transfer time 6 ms typical, 10 ms maximum
  • Weight 4 kg
Ref.: BE650G2-FR
2 279,00 DHincl. VAT

Out of stock

Under Law 09-08, you have the right to access, rectify and object to the processing of your personal data. This processing has been authorised by the CNDP under no. D-CE-389/2015. Learn more

Can’t wait?

Ask for an alternative on WhatsApp

Quick reply

Manufacturer's datasheetView the PDF · 137 Ko — downloadable

Product overview

Entry-level UPS to protect a computer workstation and its internet box: off-line technology and 650 VA / 400 W.
Technology & protection: when the power fails, it switches to battery within a few milliseconds and protects against surges.
Power: 650 VA for 400 W of usable power — a PC, its internet box and their accessories.
Runtime: approx. 10 minutes at half load (200 W), 5 minutes at 70%.
Outlets: 8 French outlets — 6 with battery backup, 2 with surge protection only; plus a USB charging port for your devices.
Ideal, for example, for a desktop computer, an internet box or a games console.
Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.

See all the specifications ↓
Request a quoteShare:

Technical specifications

Technical specifications
Output voltage230V
Waveform typePseudo-sine wave (approximated sine wave)
Output connections6 French/Belgian outlets with battery backup + 2 French/Belgian outlets with surge protection only
Input voltage230V
Input frequency47 - 63 Hz
Input connectionsFrench/Belgian
Cord length1.8 m
Maximum input current6 A
Battery typeSealed lead-acid
Typical recharge time6 hours
Interface port1 USB port
User interfaceIlluminated display: operation, battery mode, replace battery, overload
Audible alarmAlarm when switching to battery, distinct low-battery alarm, continuous alarm on overload
Weight (kg)4 kg (4.5 kg with packaging)
Dimensions (W x D x H) (mm)130 x 365 x 120 mm
Estimated battery service life (years)2 to 5 years
TechnologyOff-line
Technical specifications (continued)
Power (VA)650 VA
Voltage stabiliserNo
Box contentsUser manual
Data line protectionTelephone / fax / modem / DSL line (RJ45) and 10/100 Base-T Ethernet network line (RJ45)
Surge protection and filtering310 J
Transfer/switching time6 ms typical, 10 ms maximum
Audible noise45 dBA
CertificationsCE · EAC · RoHS
Operating temperature0 to 40 °C
Output frequency47...63 Hz mains synchronisation; 50 Hz +/- 1 Hz when not synchronised
Phase (output/input)Single-phase / Single-phase
Output typeFR outlets
Power (W)400 W
Runtime50% load (200 Watts): 10 minutes / 70% load (280 Watts): 5 minutes
Form factorTower
Battery-backed outlets5 to 8 outlets
Warranty2 years

Videos

Video — APC Back-UPS BE650G2-FR Off-Line UPS - 400 Watts / 650 VA - 8 FR outlets + 1 USB

Customer reviews

No reviews yet

Be the first to review this product and help other customers.

Write a review
Your rating
5/5

Shown publicly with your review.

Never published — a confirmation email will be sent to you.

Tell us about the product — in a few lines:

  • what you liked in everyday use;
  • the quality and performance you found;
  • who you would recommend it to, and why.

A question about an order, a delivery or a payment? Write to us and we will reply to you directly.

Under Law 09-08, you have the right to access, rectify and object to the processing of your personal data. This processing has been authorised by the CNDP under no. D-CE-389/2015. Learn more

Frequently asked questions about this product

How long does the Back-UPS BE650G2-FR run on battery?
10 minutes at 50% load, i.e. 200 W, and 5 minutes at 70%, i.e. 280 W. A full recharge then takes 6 hours: after a long outage, the UPS is not immediately ready to handle a second one.
How many of the eight outlets stay powered during an outage?
Six out of eight. The other two FR outlets are surge-protected but switch off with the mains. Six battery-backed outlets is generous for a unit of this size: at 650 VA, you usually find three or four battery outlets.
Does the UPS protect the internet router and the phone line?
Yes, it protects the data lines: RJ45 telephone and RJ45 Ethernet network, in addition to the power outlets. Its surge protector absorbs 310 joules on the mains side.
Can the UPS be adjusted for an unstable grid or a generator?
Yes, its voltage sensitivity is adjustable, precisely to suit unusual power supplies and generators. This is what stops it from constantly switching to battery when fed by a slightly irregular source.
What does the BE650G2-FR's wiring fault indicator report?
It warns you of a dangerous wiring problem in the wall circuit — missing earth, live and neutral reversed. It is a feature rarely found at this price, and it reveals an installation fault that endangers all connected equipment, the UPS included.
What does the UPS display show during an outage?
An illuminated display distinguishes four states: normal operation, battery mode, replace battery and overload. Three audible alarms back them up: switch to battery, low battery threshold, and a continuous tone in the event of overload.
How long does it take to switch to battery?
6 milliseconds typical, 10 maximum. The output waveform is then a stepped approximation to a sine wave, built up in steps: this is standard for off-line UPS units in this range.
Can you charge a phone on the Back-UPS BE650G2-FR?
Yes, a USB charging port is built into the unit, in addition to the eight FR outlets. It powers a phone or tablet without taking up one of the six battery-backed outlets.
How many watts can you really connect to this 650 VA unit?
400 W, not 650. It is the wattage that counts: an office desktop tower, a monitor and a router fit within it, but not a gaming PC or a laser printer. Beyond that, the UPS sounds its overload alarm as a continuous tone.
How long does the battery last before it needs replacing?
2 to 5 years depending on use and temperature. A periodic self-test monitors it and signals that a replacement is due before it fails, via the dedicated indicator on the display — you do not find out on the day of an outage.
How much space does the UPS take up, and is it noisy?
13 cm wide, 36.5 cm deep, 12 cm high, weighing 4 kg: a compact format that slips behind a desktop tower. It is rated at 45 dBA, so it is better placed on the floor than next to the monitor.
Is the APC Back-UPS BE650G2-FR new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 2 years. The unit is CE, EAC and RoHS certified and complies with EN/IEC 62040-1 and 62040-2; the datasheet lists all the values.

Trending

View the APC archive

Chat on WhatsApp

Scan with my phone

The simplest way: open your phone camera and point it at this code. The chat opens with your message ready.

Open WhatsApp Web

Works if your phone is already linked to this computer.