Image 1 of 3
nJoy
Product reference:UPCMTOP960HASCGnJoy Aster 6KT Online UPS - 5400 W / 6000 VA - Terminal block (UPCMTOP960HASCG)
Product reference:UPCMTOP960HASCG
- Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
- With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
- Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
- Terminal block connection: fixed wiring, to be installed by an electrician
- Pure sine wave output
- USB HID and RS-232 ports for automatic server shutdown
- SNMP port for remote supervision with an optional card
- Power Master software for monitoring
- Multifunction colour LCD screen
- Internal bypass and cold start
- EPO function (emergency power off)
- Accepted input voltage from 80 to 300 V
- Efficiency up to 96% in ECO mode
- Active cooling: below 55 dB, best kept in a technical room
- Tower format, 20.55 kg without the batteries
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
- Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
- With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
- Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
- Terminal block connection: fixed wiring, to be installed by an electrician
- Pure sine wave output
- USB HID and RS-232 ports for automatic server shutdown
- SNMP port for remote supervision with an optional card
- Power Master software for monitoring
- Multifunction colour LCD screen
- Internal bypass and cold start
- EPO function (emergency power off)
- Accepted input voltage from 80 to 300 V
- Efficiency up to 96% in ECO mode
- Active cooling: below 55 dB, best kept in a technical room
- Tower format, 20.55 kg without the batteries
A high-power online UPS for server rooms: online double conversion, 6 kVA / 5400 W.
Technology & protection: power is fully and continuously regenerated — the equipment is never exposed to the mains, with zero transfer time. Maximum protection against outages, surges, voltage fluctuations and electrical noise.
Power: 6 kVA for 5400 W of real power (0.9 power factor) — almost all of the rated power is available in watts.
Ports: terminal block connection (hard-wired by an electrician).
To be installed in a technical room.
Designed, for example, for server racks and critical business infrastructure.
LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software.
Batteries not included: 16 × 12 V batteries to be ordered separately. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
In stock Warranty 3 years
14 799 DHincl. VAT
Order via WhatsApp — nJoy Aster 6KT Online UPS - 5400 W / 6000 VA - Terminal block (UPCMTOP960HASCG)
✓ In stock · Delivered 7 – 12 Nov · Delivery free · Free pickup
Price: 14 799,00 DH incl. VAT
In stock
Order via WhatsApp — nJoy Aster 6KT Online UPS - 5400 W / 6000 VA - Terminal block (UPCMTOP960HASCG)
Deliveryfree
✓ In stock · Between Sat 7 Nov and Thu 12 Nov
Free pickup
Casablanca storewithin 24 h
Témara pickup pointwithin 48 h
Warranty
3 years