Delta Power Solutions Amplon RT 3K Online Rack/Tower UPS - 2700 W / 3000 VA - 6 C13 + 1 C19 Outlets (UPS302R2RT2B035)
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
3000 VA / 2700 W, online double conversion
2U rack or tower, brackets and rail kit included
Pure sine wave, zero transfer time
Runtime: 7 min at 75% load
Extendable with an optional 72 V Delta external battery pack
Hot-swappable internal batteries
6 C13 outlets in two groups and 1 C19 16 A outlet
Efficiency up to 94% online, up to 97% in ECO mode
An online double-conversion UPS for a server or network rack, in 2U rack or tower format: pure sine wave, hot-swappable batteries and rail kit included. Power: 3000 VA / 2700 W (power factor 0.9). Runtime: 7 min at 75% load, extendable with an optional Delta external battery pack. Outlets: 6 C13 outlets in two groups and 1 C19 16 A outlet; secondary loads can be cut on battery to extend the runtime of essential equipment. Management: swivelling LCD screen, USB and RS-232, remote emergency power off and a SMART slot for an SNMP card. Efficiency: up to 94% in online mode, up to 97% in ECO mode. The most powerful Amplon RT (28 kg, 610 mm deep), ideal for example for several servers, a storage rack or telecom equipment.
The Amplon RT 3K carries the load of several servers in the same rack height as its smaller siblings. What changes is everything else: depth, weight, mains connection. Here is what to plan before mounting it.
2,700 Wof real output power, for 3,000 VA
97 %peak efficiency, in ECO mode
50 °Coperating, with power reduced to 80% above 40 °C
Plan for 610 mm and two pairs of arms
The unit measures 440 × 610 × 89 mm and weighs 28 kg: it needs a deep enough four-post rack, and Delta recommends lifting it with two people. Alone, you first remove the internal batteries, then refit them once the UPS is fixed. The brackets and rails are in the box, and only those should be used for mounting. Air enters through the front and exits at the back.
Runtime is added inside the rack
With its internal batteries, it lasts 7 minutes at 75% load as a typical value. To go further, Delta offers a 72 V external battery pack, sold as an option: same front, same 610 mm depth, but 44 kg to fit into the rack. It connects hot, just as the internal batteries are replaced.
On top the UPS, below the external battery pack, sold as an option.
A mains connection sized for 3 kVA
The input is a C20 inlet protected by a 25 A breaker, with the 16 A input cord included: the wall outlet must match. On the output side, the six C13 outlets share 13.5 A, and the C19 outlet alone can deliver 13.5 A to the most power-hungry device.
Rear panel of the Amplon RT 3K, from the Delta manual.
On a site backed up by a generator, the Amplon RT 3K is declared generator compatible: its batteries hold while the generator starts.
Technical specifications
Technical specifications
Output voltage
200/208/220/230/240 V ± 1% (linear load)
Waveform type
Pure sine wave
Output harmonic distortion
< 3% at linear load
Output connections
(6) IEC C13 in 2 groups of 3 (LOAD 1 / LOAD 2), non-critical loads can be shed + (1) IEC C19
Input voltage
200/208/220/230/240 V (200 and 208 V with derating to 90%)
Input frequency
40 - 70 Hz (50/60 Hz ± 10 Hz)
Input connections
1 IEC C20 inlet, 25 A input circuit breaker
Voltage range
120 - 280 V (175 - 280 V at full load, 120 - 175 V between 70 and 100% load)
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Can the Amplon RT 3K be installed in a 19-inch rack?
Yes. It takes 2U in a 19-inch rack, with its mounting brackets and rail kit included in the box; allow 610 mm of depth. It can also stand upright in tower format with the optional Delta tower stand kit; its LCD screen swivels to stay readable in both positions.
How much runtime does the Delta Amplon RT 3K offer?
About 7 min at 75% load with its internal batteries. To last longer, it connects to an optional Delta 72 V external battery pack (same 2U format), which can be added or removed without powering down the equipment. Cutting secondary loads on battery also extends the runtime of essential devices.
Can the batteries of the Amplon RT 3K be replaced without shutting everything down?
Yes, its internal batteries are hot-swappable: the equipment stays powered during the intervention. They are sealed, maintenance-free 12 V / 9 Ah lead-acid batteries; replacement must be done or supervised by a qualified technician, using the same number and type of batteries.
How can the Delta Amplon RT 3K be monitored?
Through its USB or RS-232 port with the UPSentry 2012 software: automatic server shutdown, event log, battery self-test and remaining-time estimate. Its SMART slot accepts an optional SNMP card for network monitoring, a relay card or a Modbus card, and a REPO contact allows remote emergency power off.
How is the Amplon RT 3K connected to the mains?
Through its IEC C20 inlet, protected by a 25 A circuit breaker, with the supplied 16 A input cord. Plan a wall socket and a line rated for that current: at 2700 W, the UPS draws far more than a PC. On the output side, a 10 A cord and a 16 A cord are supplied for the first devices.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
An online double-conversion 2U rack or tower UPS for a network rack: 900 W of pure sine wave power, hot-swappable batteries, runtime extendable with an external pack and rail kit included.
The most powerful Amplon N: 2700 W of pure sine wave power with no transfer time for several servers or a rack, on 6 internal batteries, with 13 minutes at half load and an input tolerated from 80 to 280 V.
The network management card is already included: the UPS is monitored and controlled remotely with nothing more to buy. 1000 W genuinely available, 28 minutes of runtime at half load (500 W) and under 35 dB.
•SNMP network management card included, for remote monitoring
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•1000 VA / 900 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
7 416 DHincl. VAT7 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3000 VA / 2700 W, online double conversion
•Pure sine wave, zero transfer time
•Runtime: 13 min at half load, 4.5 min at full load
In stock
9 799 DHincl. VAT9 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
1000 W genuinely available, power factor of 1
In stock
18 999 DHincl. VAT18 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
8 799 DHincl. VAT8 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
19 499 DHincl. VAT19 499,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
6 C13 outlets, the format used by computer and server power cords, all battery-backed
In stock
51 199 DHincl. VAT51 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician