Delta Power Solutions Amplon N 3K Online UPS - 2700 W / 3000 VA - 6 C13 + 1 C19 Outlets (UPS302N2000B035)

The most powerful Amplon N: 2700 W of pure sine wave power with no transfer time for several servers or a rack, on 6 internal batteries, with 13 minutes at half load and an input tolerated from 80 to 280 V.

  • 3000 VA / 2700 W, online double conversion
  • Pure sine wave, zero transfer time
  • Runtime: 13 min at half load, 4.5 min at full load
  • 6 C13 outlets and 1 C19 16 A outlet
  • 80 to 280 V input, generator compatible
  • Efficiency up to 93%
  • LCD screen, USB port and UPSentry 2012 software
  • MINI slot for an optional SNMP, relay or Modbus card
  • 6 internal 12 V / 9 Ah batteries
  • 190 × 390 × 325 mm tower
Ref.: UPS302N2000B035
9 799,00 DHincl. VAT

Out of stock

Under Law 09-08, you have the right to access, rectify and object to the processing of your personal data. This processing has been authorised by the CNDP under no. D-CE-389/2015. Learn more

Can’t wait?

Ask for an alternative on WhatsApp

Quick reply

Manufacturer's datasheetView the PDF · 206 Ko — downloadable

Product overview

An online double-conversion UPS for a server rack or critical equipment: pure sine wave, zero transfer time and 2700 W of real power.
Technology: power is rebuilt continuously; your equipment never sees the outages, noise or fluctuations of the grid.
Power: 3000 VA / 2700 W (power factor 0.9), on 6 internal 12 V / 9 Ah batteries.
Runtime: 13 min at half load, 4.5 min at full load.
Outlets: 6 C13 outlets and 1 C19 16 A outlet for power-hungry equipment.
Management: LCD screen, USB port, UPSentry software and an SNMP card slot (optional card).
Efficiency up to 93% and an input of 80 to 280 V: it withstands the most unstable grid, ideal for example for several servers, a storage rack or telecom equipment.

See all the specifications ↓
Request a quoteShare:

Description

Delta Amplon N 3K · UPS302N2000B035

A whole rack held up by one UPS

The most powerful Amplon N delivers 2,700 W in double conversion from six internal 12 V, 9 Ah batteries. The front carries the screen and three buttons; all the wiring goes through the back, where seven outlets wait for servers, storage and network.

Amplon N 3K seen from the front in three quarters on the left and from the back on the right, with its C13 outlets, C19 outlet and two fans

2,700 real watts, not just 3,000 VA

  • 2,700 Wusable from 3,000 VA, power factor 0.9
  • 80 Vlowest voltage held on mains, at half load
  • 93 %efficiency in double conversion

A UPS is labelled in VA, but it is the watts that tell you what you can plug in. With a power factor of 0.9, its 3,000 VA give 2,700 W; at a factor of 0.8, the same label would give only 2,400. Those 300 W are headroom for adding a device.

On a weak line it stays on mains: full load from 175 to 280 V, and down to 80 V by bringing the accepted load down to half. The batteries are kept for real outages.

Efficiency reaches 93% in double conversion and stays at 91% at half load: less energy lost as heat in the room. On the input side, a power factor above 0.99 and harmonic distortion below 3% spare the electrical installation, generator included.

Three ways to control it

The same UPS is controlled from its front panel, from a computer connected over USB or from the network: choose according to the size of the room and how many people look after it.

Three buttons, SETUP, ON and OFF, and a screen showing input or output voltage and frequency, load in kVA, kW or percent, battery status, temperature and, during an outage, the remaining backup time. Holding a button for 3 seconds in normal operation starts a 10-second battery test. In setup mode you set the output voltage and frequency, the bypass range and the overload alarm, and you can mute the buzzer.

Connected to a computer through its USB port, with the virtual COM port driver and UPSentry 2012 software, the UPS is monitored from the desk: live status, estimated battery reserve before or during an outage, and an automatic battery test at regular intervals, which the panel alone cannot schedule.

The MINI slot at the back takes an optional card: SNMP to supervise the UPS over the network, relay I/O to connect its states to a contact-based installation, Modbus for building management, or TVSS to add surge protection. No card is supplied: you equip the UPS to suit the room.

What it powers, and what it refuses

Six C13 outlets and one C19 outlet: the original cords of servers, storage arrays and switches plug straight in, and the C19 takes the most power-hungry device.

  • YesComputers, servers and their peripherals: monitors, modems, external hard drives, tape backup drives.
  • NoLoads that feed energy back into the UPS, and asymmetrical loads such as a half-wave rectifier.
  • Never in a loopThe UPS input cord never plugs into its own output outlets.

Where to put it: in a temperate, dry room, with 15 cm clear on every side for ventilation and the grilles never covered. Connect it to an earthed outlet, without an extension cord, with upstream and downstream protection installed within easy reach. In a dusty room, fit it with a dust filter.

The same 190 × 390 × 325 mm cabinet exists in 2 kVA: the Amplon N 2K, with 1,800 W and four batteries.

The right model for what you protect

Up to 1,800 W, the Amplon N 2K does the same job in the same cabinet. For a 19-inch rack, or to add an external battery pack, the Amplon RT 3K fits in 2U. For a single PC and its monitor, a line-interactive unit such as the Agilon VX 1000 is enough. Delta's UPS range runs from 600 VA to 4,000 kVA, and its manufacturing system is certified ISO 9001 and ISO 14001.

Technical specifications

Technical specifications
Output voltage220/230/240 V ± 2% (linear load)
Waveform typePure sine wave
Output harmonic distortion< 3% at linear load
Output connections(6) IEC C13 + (1) IEC C19
Input voltage220/230/240 V
Input frequency50/60 Hz ± 10 Hz
Input connections1 IEC C20 inlet (16 A input cord included)
Voltage range80 - 280 V (175 - 280 V at full load, 80 - 175 V between 50 and 100% load)
Battery typeSealed lead-acid, 6 x 12 V / 9 Ah (72 V)
Battery managementIntelligent charge management; cold start on battery
Typical recharge time4 hours to 90% charge
Interface port1 USB port
User interfaceLCD screen and LED indicators
Audible alarmYes, beeper can be muted from the panel
Power management softwareUPSentry 2012 (Delta)
Weight (kg)24.4 kg
Dimensions (W x D x H) (mm)190 x 390 x 325 mm
TechnologyOn-line
Power (VA)3,000 VA
Voltage stabiliserYes
Box contentsUPS · 16 A input cord · 10 A output cord · 16 A output cord · User manual
Technical specifications (continued)
Preinstalled batteriesYes, internal batteries
Communication card slot1 MINI slot for an SNMP, relay, Modbus or TVSS card (optional, not included)
Transfer/switching time0 ms (continuous double conversion)
Cold startYes
BypassInternal automatic bypass
Audible noise< 48 dBA
Power factor (ratio)0.9
Crest factor3:1
Input power factor> 0.99 (full load)
Output frequency50/60 Hz ± 0.05 Hz
Phase (output/input)Single-phase / Single-phase
Overload capacity< 105% continuous; 105 to 125% for 1 minute; 125 to 150% for 30 seconds
Double-conversion efficiencyUp to 93%
Output typeC13 outlets
Power (W)2,700 W
Runtime13 min at half load; 7 min at 75% load; 4.5 min at full load
External battery packsNone (no external battery pack)
Form factorTower
Battery-backed outlets5 to 8 outlets
Control & communicationUSB, Card slot
Warranty2 years

Specific references

EAN4710901733407
MPNUPS302N2000B035

Customer reviews

No reviews yet

Be the first to review this product and help other customers.

Write a review
Your rating
5/5

Shown publicly with your review.

Never published — a confirmation email will be sent to you.

Tell us about the product — in a few lines:

  • what you liked in everyday use;
  • the quality and performance you found;
  • who you would recommend it to, and why.

A question about an order, a delivery or a payment? Write to us and we will reply to you directly.

Under Law 09-08, you have the right to access, rectify and object to the processing of your personal data. This processing has been authorised by the CNDP under no. D-CE-389/2015. Learn more

Frequently asked questions about this product

How much runtime does the Delta Amplon N 3K UPS offer?
About 13 minutes at half load, 7 minutes at 75% load and 4.5 minutes at full load (2700 W). That is enough time to finish a task and shut the servers down cleanly, or to hold until a generator starts. This model does not accept an external battery pack: for more runtime, you need a model with extendable batteries.
Why choose the online Amplon N 3K rather than a line-interactive UPS?
Because it rebuilds the power continuously: your equipment is powered by the UPS, never directly by the grid. No transfer time when power fails, a pure sine wave and an output voltage held within ± 2%, even when the mains varies from 80 to 280 V. It is the protection expected for a server or critical equipment.
Which equipment can be connected to the Delta Amplon N 3K?
Six devices on its IEC C13 outlets, the format of servers, NAS, switches and PCs, plus one power-hungry device on the 16 A C19 outlet. A 10 A output cord and a 16 A output cord are included. The UPS itself connects to the mains with its 16 A input cord, on a wall socket rated for that current.
Can the Amplon N 3K be monitored remotely?
Yes. Through its USB port and the UPSentry 2012 software, it triggers the automatic shutdown of servers and tracks the battery status. Its MINI slot accepts an optional SNMP card for network monitoring, a relay contact card or a Modbus card for building management.
What is the difference between the Amplon N 3K and the Amplon N 2K?
The 3K delivers 3000 VA / 2700 W versus 2000 VA / 1800 W, with six 12 V / 9 Ah batteries instead of four, and announces the same typical runtime at an equal load ratio, 13 minutes at half load. Both share the 190 × 390 × 325 mm tower case, the 6 C13 outlets and the C19 outlet; the 3K weighs 24.4 kg versus 18.6 kg.
How many watts can you plug into the Amplon N 3K?
Up to 2,700 W in total. Its power factor of 0.9 makes 90% of its 3,000 VA usable, where a UPS with a factor of 0.8 would stop at 2,400 W. Add up the watts printed on each device: the further the total stays below 2,700 W, the longer the runtime, from 4.5 minutes at full load to 13 minutes at half load.