Delta Power Solutions Amplon RT 1K Online Rack/Tower UPS - 900 W / 1000 VA - 6 C13 Outlets (UPS102R2RT2B035)
An online double-conversion 2U rack or tower UPS for a network rack: 900 W of pure sine wave power, hot-swappable batteries, runtime extendable with an external pack and rail kit included.
1000 VA / 900 W, online double conversion
2U rack or tower, brackets and rail kit included
Pure sine wave, zero transfer time
Runtime: 6.5 min at 75% load
Extendable with an optional 24 V Delta external battery pack
Hot-swappable internal batteries
6 C13 outlets in two groups, load shedding possible
An online double-conversion UPS for a server or network rack, in 2U rack or tower format: pure sine wave, hot-swappable batteries and rail kit included. Power: 1000 VA / 900 W (power factor 0.9). Runtime: 6.5 min at 75% load, extendable with an optional Delta external battery pack. Outlets: 6 C13 outlets in two groups; secondary loads can be cut on battery to extend the runtime of essential equipment. Management: swivelling LCD screen, USB and RS-232, remote emergency power off and a SMART slot for an SNMP card. Efficiency: 90% in online mode, 96% in ECO mode. The most compact Amplon RT (12 kg, 335 mm deep), ideal for example for a switch, a rack NAS or a small server.
Two units high and 335 mm deep: the Amplon RT 1K fits a shallow four-post network rack, or stands upright next to the switch it protects. Its front carries only the screen, the indicators and three buttons; everything else plugs in at the back.
900 usable watts in two rack units
900 Wusable from 1,000 VA, power factor 0.9
120 Vlowest voltage held on mains, at 70% load
50 °Cin operation, power reduced to 80% above 40 °C
A UPS is labelled in VA, but it is the watts that tell you what you can plug in. With a power factor of 0.9, its 1,000 VA give 900 W; at a factor of 0.8, the same label would give only 800.
When the mains sags, it stays on the grid: full load from 175 to 280 V, and down to 120 V while keeping 70% of the load. The batteries are kept for real outages, which spares them.
In a technical room without air conditioning it runs up to 50 °C, and it reports a failed fan. Efficiency: 90% in double conversion, 96% in ECO mode on stable mains.
Everything is wired at the back
This is the rear panel as Delta draws it for this reference. Mains power comes in through a C14 inlet protected by an 8 A breaker; on the output side, six C13 outlets split into two groups share 4.5 A in total. On the right, a 24 V connector awaits the optional battery pack, and a SMART slot takes a network card.
C14 inlet and 8 A breakerLOAD 1: three C13 outletsLOAD 2: three C13 outlets24 V battery pack connectorSMART slot: SNMP, relay or Modbus cardREPO, RS-232 and USB to the server
Drop the extras, keep what matters
The two outlet groups are not just for tidying cables. During an outage, the UPS can shed non-critical loads to save its battery for the devices that count. So the router and the NAS go on one group, the rack monitor or a test workstation on the other: when power fails, the minutes go to the network first.
More runtime without switching anything off
The internal batteries are replaced hot, with the equipment still powered. To last longer, Delta offers a 24 V external battery pack, sold as an option: same 2U front, same 335 mm depth, 15 kg, and it too connects without shutting the rack down.
On top the UPS, below the external battery pack, sold as an option.
Before installing it. Air enters through the front and leaves at the back: keep space behind a solid rack door. In a rack, lift it with two people, or remove the internal batteries first. The brackets and rails are in the box; to stand it upright, the tower feet are a Delta option.
The right model for what you protect
More than 900 W to protect in the same rack height: the Amplon RT 2K or the Amplon RT 3K. For a single PC and its monitor, outside a rack, a line-interactive unit such as the Agilon VX 1000 is enough. Delta's UPS range runs from 600 VA to 4,000 kVA, and its manufacturing system is certified ISO 9001 and ISO 14001.
Technical specifications
Technical specifications
Output voltage
200/208/220/230/240 V ± 1% (linear load)
Waveform type
Pure sine wave
Output harmonic distortion
< 3% at linear load
Output connections
(6) IEC C13 in 2 groups of 3 (LOAD 1 / LOAD 2), non-critical loads can be shed
Input voltage
200/208/220/230/240 V (200 and 208 V with derating to 90%)
Input frequency
40 - 70 Hz (50/60 Hz ± 10 Hz)
Input connections
1 IEC C14 inlet, 8 A input circuit breaker
Voltage range
120 - 280 V (175 - 280 V at full load, 120 - 175 V between 70 and 100% load)
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Can the Amplon RT 1K be installed in a 19-inch rack?
Yes. It takes 2U in a 19-inch rack, with its mounting brackets and rail kit included in the box; allow 335 mm of depth. It can also stand upright in tower format with the optional Delta tower stand kit; its LCD screen swivels to stay readable in both positions.
How much runtime does the Delta Amplon RT 1K offer?
About 6.5 min at 75% load with its internal batteries. To last longer, it connects to an optional Delta 24 V external battery pack (same 2U format), which can be added or removed without powering down the equipment. Cutting secondary loads on battery also extends the runtime of essential devices.
Can the batteries of the Amplon RT 1K be replaced without shutting everything down?
Yes, its internal batteries are hot-swappable: the equipment stays powered during the intervention. They are sealed, maintenance-free 12 V / 9 Ah lead-acid batteries; replacement must be done or supervised by a qualified technician, using the same number and type of batteries.
How can the Delta Amplon RT 1K be monitored?
Through its USB or RS-232 port with the UPSentry 2012 software: automatic server shutdown, event log, battery self-test and remaining-time estimate. Its SMART slot accepts an optional SNMP card for network monitoring, a relay card or a Modbus card, and a REPO contact allows remote emergency power off.
Does the Amplon RT 1K work in a hot technical room?
Yes, up to 50 °C: between 40 and 50 °C, its available power is reduced to 80%, i.e. 720 W. Its fan speed adapts to the load to limit noise, 40 dBA in operation. It also accepts an input of 120 to 280 V and power from a generator, two assets on an unstable grid.
How many watts can you plug into the Amplon RT 1K?
Up to 900 W in total. Its power factor of 0.9 makes 90% of its 1,000 VA usable, where a UPS with a factor of 0.8 would stop at 800 W. Add up the watts printed on each device: at 75% load, its internal batteries last about 6.5 minutes.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Short 438 mm depth for small racks: power continuously regenerated with zero transfer time, 4 C13 outlets, hot-swappable batteries and automatic server shutdown over USB or RS232.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
10 399 DHincl. VAT10 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed