Delta Power Solutions Agilon VX 1000 Line-Interactive UPS - 600 W / 1000 VA - 4 C13 Outlets (UPA102V210035)
A line-interactive UPS for a complete workstation and a network device. Two 12 V / 7 Ah batteries, an AVR regulator that spares the battery and a USB port to shut the PC down cleanly during an outage.
1000 VA / 600 W, line-interactive technology
AVR voltage regulator: accepts 170 to 280 V input
4 C13 outlets, the format of computer and monitor cords
2 x 12 V / 7 Ah batteries, recharged even when off
Runtime: 5 min at half load
Transfer to battery in 2 to 6 ms
LCD touch screen and USB port for automatic shutdown
A line-interactive UPS for a complete workstation: AVR voltage regulator, LCD touch screen and automatic shutdown over USB. Power: 1000 VA / 600 W. Protection: the battery takes over in 2 to 6 ms when power fails, and the AVR corrects voltage dips and surges without drawing on the battery. Battery: 2 x 12 V / 7 Ah batteries, 5 min at half load, recharged even when the UPS is off. Outlets: 4 C13 outlets, the format of computer and monitor power cords. Comfort: under 40 dBA and cold start on battery, even without mains power. The middle of the Agilon VX range, with twice the battery of the VX 600, ideal for example for a PC, a monitor and a switch.
The VX 1000 takes the VX 600 format and makes it bigger: 1000 VA for 600 W of real power, two 12 V / 7 Ah batteries instead of one, and the same four C13 outlets. Enough to protect a desktop PC, its monitor and a switch, with headroom on power.
What it does without being asked
Once installed, the VX 1000 expects nothing from its user: it corrects the voltage, keeps its batteries full and takes over again on its own after an outage.
Restarts on its ownWhen power returns, the UPS starts again without anyone pressing a button.
Charges while offThe batteries recharge even with the UPS switched off, as long as it stays plugged in.
SurgesSurge protection guards the connected devices.
Up to 95% efficiencyOn mains power, the UPS loses little energy as heat.
What it does depending on the power
As long as the grid supplies the office, the VX 1000 lets the power through and corrects it when needed: its automatic regulator makes up for voltage dips and surges between 170 and 280 V without drawing on the batteries. On a wavering grid, this avoids repeated transfers and keeps the reserve intact. The batteries recharge continuously, even when the UPS is off: 6 to 8 hours to get back to 90%.
As soon as the mains disappear, the batteries take over in 2 to 6 ms and last 5 minutes at half load. An alarm sounds on battery, then again when it runs low. Connected to the PC over USB, the ViewPower software triggers a clean shutdown of the computer before the reserve is empty; when power returns, the UPS restarts on its own.
At the back, the wiring of an office
A row of four IEC C13 outlets for PC, monitor and switch cords, the mains inlet with its fuse holder just below, and the USB port at the top right. The box includes the power cord, an output cord and the USB cable. Never connect a laser printer or a scanner: Delta rules them out because their inrush current overloads the UPS.
Who it is for: a complete workstation — PC, monitor, network device — that must shut down cleanly during an outage. For a heavier workstation, the VX 1500 adds two outlets and larger batteries.
The right VX for the desk you protect
Add up the watts printed on each device: the total must stay below the UPS's usable power. See also the VX 600 and the VX 1500.
VX 600360 W, one 12 V / 7 Ah battery, four C13 outlets: a desktop PC and its monitor.
VX 1000600 W, two 12 V / 7 Ah batteries, four C13 outlets: the PC, the monitor and the router or switch.
VX 1500900 W, two 12 V / 9 Ah batteries, six C13 outlets: a workstation and its monitors, or a NAS and its switch.
For a server, or equipment that cannot tolerate even a micro-cut, move to double conversion: the Amplon N 2K rebuilds the power continuously. Delta's UPS range runs from 600 VA to 4,000 kVA, and its manufacturing system is certified ISO 9001 and ISO 14001.
Technical specifications
Technical specifications
Output voltage
230 V ± 10% (battery mode)
Waveform type
Simulated sine wave (battery mode)
Output connections
(4) IEC C13
Input voltage
230 V
Input frequency
45 - 65 Hz
Input connections
1 IEC C14 inlet (mains cord included)
Voltage range
170 - 280 V (at full load)
Automatic voltage regulation (AVR)
Built-in AVR: corrects voltage dips and surges without switching to battery
Battery type
Sealed lead-acid, 2 x 12 V / 7 Ah
Battery management
Automatic recharge even when the UPS is off; automatic restart when power returns
Typical recharge time
6 to 8 hours to 90% charge
Interface port
1 USB port
User interface
LCD touch screen
Audible alarm
Yes: battery mode, low battery, overload, fault
Power management software
ViewPower (Delta): automatic shutdown and remote control
Weight (kg)
8.2 kg
Dimensions (W x D x H) (mm)
130 x 320 x 182 mm
Technology
Line Interactive
Power (VA)
1,000 VA
Technical specifications (continued)
Voltage stabiliser
Yes
Box contents
UPS · Mains power cord · IEC 10 A output cord · USB cable · Quick installation guide
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How much runtime does the Delta Agilon VX 1000 offer?
About 5 minutes at half load, i.e. 300 W connected. That is enough time to save your work and shut the computer down cleanly, which the ViewPower software can do on its own over the USB port. With a lighter load the runtime gets longer; with a heavier load it gets shorter.
Which devices can be connected to the Delta Agilon VX 1000?
Devices with computer power cords: its 4 outlets are IEC C13, the format used by desktop PCs, monitors, switches and servers. Never plug in a laser printer or a scanner: their inrush current overloads the UPS. With 600 W of real power, it backs up for example a desktop PC, its monitor and a switch, with some power headroom to spare.
What is the difference between the Delta VX 1000 and the VX 600?
The VX 1000 doubles the energy reserve with two 12 V / 7 Ah batteries instead of one, and rises to 1000 VA / 600 W versus 600 VA / 360 W. It keeps the VX 600's 4 C13 outlets, AVR, LCD touch screen and USB port, in a larger 8.2 kg case.
What is the AVR voltage regulator of the Delta VX 1000 for?
It corrects mains voltage dips and surges without switching to the battery. The UPS accepts an input of 170 to 280 V while keeping your devices on mains power: fewer transfers on an unstable grid, and a battery saved for real outages.
Can the Delta Agilon VX 1000 shut my computer down by itself?
Yes. Connect its USB port to the PC with the supplied cable and install Delta's ViewPower software: during a prolonged outage, it triggers an automatic, clean shutdown of the computer before the battery runs out, and lets you monitor the UPS remotely.
What is in the box of the Delta Agilon VX 1000?
The UPS, a mains power cord, an IEC 10 A output cord, a USB cable and a quick installation guide. The batteries are already installed: the UPS plugs in and goes into service directly, after a first 6-hour charge recommended before use.
Automatic voltage regulation (AVR) that steadies the power without drawing on the battery. Enough runtime to save your work and shut the PC down cleanly during an outage.
•Runtime: around 14 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime to save your work and shut the PC down cleanly during an outage.
Automatic voltage regulation (AVR) that steadies the power without drawing on the battery. Enough runtime for a desktop PC and its monitor, long enough to save everything.
A compact line-interactive UPS for a PC and its monitor. Its AVR regulator corrects voltage fluctuations without wearing the battery, and its USB port triggers a clean shutdown of the computer during an outage.
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Compact and quiet, designed for a light day-to-day workstation.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Stabilises the current and protects a workstation and its peripherals against outages and surges, without drawing on the battery during voltage fluctuations. Around 9 minutes of runtime at half load.
Protects a light computer setup against outages and surges thanks to its built-in voltage regulator. Around 7 minutes of runtime at half load, enough time to save and shut down properly.
Compact desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.