Delta Power Solutions Agilon VX 600 Line-Interactive UPS - 360 W / 600 VA - 4 C13 Outlets (UPA601V210035)
A compact line-interactive UPS for a PC and its monitor. Its AVR regulator corrects voltage fluctuations without wearing the battery, and its USB port triggers a clean shutdown of the computer during an outage.
600 VA / 360 W, line-interactive technology
AVR voltage regulator: accepts 170 to 280 V input
4 C13 outlets, the format of computer and monitor cords
Runtime: 5.7 min at half load
Transfer to battery in 2 to 6 ms
LCD touch screen: mode, AVR, battery level and alarms
USB port and ViewPower software for automatic shutdown
A line-interactive UPS to protect a workstation: AVR voltage regulator, LCD touch screen and automatic shutdown over USB. Power: 600 VA / 360 W. Protection: the battery takes over in 2 to 6 ms when power fails, and the AVR corrects voltage dips and surges without drawing on the battery. Battery: 1 x 12 V / 7 Ah battery, 5.7 min at half load, recharged even when the UPS is off. Outlets: 4 C13 outlets, the format of computer and monitor power cords. Comfort: under 40 dBA and cold start on battery, even without mains power. The entry model of the Agilon VX range, ideal for example for a desktop PC, a monitor or a POS terminal.
A 600 VA line-interactive UPS delivering 360 W of real power, designed for a desktop PC and its monitor. When the mains sag, its regulator restores the voltage without touching the battery; when power fails, the battery takes over and leaves time to save and shut down.
What it does without being asked
Once installed, the VX 600 expects nothing from its user: it corrects the voltage, keeps its batteries full and takes over again on its own after an outage.
Restarts on its ownWhen power returns, the UPS starts again without anyone pressing a button.
Charges while offThe batteries recharge even with the UPS switched off, as long as it stays plugged in.
SurgesSurge protection guards the connected devices.
Up to 95% efficiencyOn mains power, the UPS loses little energy as heat.
Everything plugs in at the back, in four moves
The rear panel gathers what you connect once and for all. The four outlets use the IEC C13 format, that of PC and monitor power cords: the box includes an output cord for the first device. Delta forbids connecting a laser printer or a scanner, whose inrush current overloads the UPS.
USB port: automatic PC shutdown with ViewPowerMains inlet, cord includedFuse holder, with its spare fuse4 C13 outlets for the PC and monitor
The mains waver, the battery stays full
Between 170 and 280 V, the automatic voltage regulator corrects mains dips and surges without switching to battery: fewer needless transfers on an unstable grid, and a battery saved for real outages. When power fails, the transfer takes 2 to 6 ms, then the 12 V / 7 Ah battery lasts 5.7 minutes at half load. Without mains power, the UPS can even start on its battery. The touch LCD screen shows the voltage and the UPS status at a glance.
For a more demanding workstation or more devices to protect, the VX 1000 adds a second battery and the VX 1500 two more outlets.
The right VX for the desk you protect
Add up the watts printed on each device: the total must stay below the UPS's usable power. See also the VX 1000 and the VX 1500.
VX 600360 W, one 12 V / 7 Ah battery, four C13 outlets: a desktop PC and its monitor.
VX 1000600 W, two 12 V / 7 Ah batteries, four C13 outlets: the PC, the monitor and the router or switch.
VX 1500900 W, two 12 V / 9 Ah batteries, six C13 outlets: a workstation and its monitors, or a NAS and its switch.
For a server, or equipment that cannot tolerate even a micro-cut, move to double conversion: the Amplon N 2K rebuilds the power continuously. Delta's UPS range runs from 600 VA to 4,000 kVA, and its manufacturing system is certified ISO 9001 and ISO 14001.
Technical specifications
Technical specifications
Output voltage
230 V ± 10% (battery mode)
Waveform type
Simulated sine wave (battery mode)
Output connections
(4) IEC C13
Input voltage
230 V
Input frequency
45 - 65 Hz
Input connections
1 IEC C14 inlet (mains cord included)
Voltage range
170 - 280 V (at full load)
Automatic voltage regulation (AVR)
Built-in AVR: corrects voltage dips and surges without switching to battery
Battery type
Sealed lead-acid, 1 x 12 V / 7 Ah
Battery management
Automatic recharge even when the UPS is off; automatic restart when power returns
Typical recharge time
6 to 8 hours to 90% charge
Interface port
1 USB port
User interface
LCD touch screen
Audible alarm
Yes: battery mode, low battery, overload, fault
Power management software
ViewPower (Delta): automatic shutdown and remote control
Weight (kg)
4.4 kg
Dimensions (W x D x H) (mm)
101 x 279 x 142 mm
Technology
Line Interactive
Power (VA)
600 VA
Technical specifications (continued)
Voltage stabiliser
Yes
Box contents
UPS · Mains power cord · IEC 10 A output cord · USB cable · Quick installation guide
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How much runtime does the Delta Agilon VX 600 offer?
About 5.7 minutes at half load, i.e. 180 W connected. That is enough time to save your work and shut the computer down cleanly, which the ViewPower software can do on its own over the USB port. With a lighter load the runtime gets longer; with a heavier load it gets shorter.
Which devices can be connected to the Delta Agilon VX 600?
Devices with computer power cords: its 4 outlets are IEC C13, the format used by desktop PCs, monitors and servers. Never plug in a laser printer or a scanner: their inrush current overloads the UPS. With 360 W of real power, it backs up for example a desktop PC and its monitor; for a heavier load, the VX 1000 or the VX 1500 take over.
What is the AVR voltage regulator of the Delta VX 600 for?
It corrects mains voltage dips and surges without switching to the battery. The UPS accepts an input of 170 to 280 V while keeping your devices on mains power: fewer transfers on an unstable grid, and a battery saved for real outages.
Can the Delta Agilon VX 600 shut my computer down by itself?
Yes. Connect its USB port to the PC with the supplied cable and install Delta's ViewPower software: during a prolonged outage, it triggers an automatic, clean shutdown of the computer before the battery runs out, and lets you monitor the UPS remotely.
Can the VX 600 start during a power outage?
Yes, it supports cold start: without mains power, it starts on its battery and immediately powers the connected devices. It also restarts on its own when power returns, and its battery recharges even when the UPS is off; allow 6 to 8 hours to bring it back to 90%.
What is in the box of the Delta Agilon VX 600?
The UPS, a mains power cord, an IEC 10 A output cord, a USB cable and a quick installation guide. The output cord connects a device directly to a C13 outlet of the UPS; the USB cable is used for the automatic shutdown of the computer.
Automatic voltage regulation (AVR) that steadies the power without drawing on the battery. Enough runtime to save your work and shut the PC down cleanly during an outage.
•Runtime: around 14 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime to save your work and shut the PC down cleanly during an outage.
Automatic voltage regulation (AVR) that steadies the power without drawing on the battery. Enough runtime for a desktop PC and its monitor, long enough to save everything.
A line-interactive UPS for a complete workstation and a network device. Two 12 V / 7 Ah batteries, an AVR regulator that spares the battery and a USB port to shut the PC down cleanly during an outage.
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Compact and quiet, designed for a light day-to-day workstation.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Stabilises the current and protects a workstation and its peripherals against outages and surges, without drawing on the battery during voltage fluctuations. Around 9 minutes of runtime at half load.
Protects a light computer setup against outages and surges thanks to its built-in voltage regulator. Around 7 minutes of runtime at half load, enough time to save and shut down properly.
Compact desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.