Delta Power Solutions Agilon VX 1500 Line-Interactive UPS - 900 W / 1500 VA - 6 C13 Outlets (UPA152V210035)
The most powerful Agilon VX: 900 W of real power on 6 C13 outlets for a workstation and its monitors or a small network corner. AVR regulator, LCD touch screen and automatic PC shutdown over USB.
1500 VA / 900 W, line-interactive technology
6 C13 outlets, the format of computer and monitor cords
AVR voltage regulator: accepts 170 to 280 V input
2 x 12 V / 9 Ah batteries, recharged even when off
Runtime: 6.8 min at half load
Transfer to battery in 2 to 6 ms
LCD touch screen and USB port for automatic shutdown
A line-interactive UPS for a powerful workstation or a small network corner: AVR voltage regulator, LCD touch screen and automatic shutdown over USB. Power: 1500 VA / 900 W. Protection: the battery takes over in 2 to 6 ms when power fails, and the AVR corrects voltage dips and surges without drawing on the battery. Battery: 2 x 12 V / 9 Ah batteries, 6.8 min at half load, recharged even when the UPS is off. Outlets: 6 C13 outlets, the format of computer and monitor power cords. Comfort: under 45 dBA with its cooling fan and cold start on battery, even without mains power. The top of the Agilon VX range, with two more outlets than the VX 1000, ideal for example for a workstation with two monitors, a NAS or a switch.
The top of the Agilon VX range is recognised by its back: six IEC C13 outlets instead of four, a cooling fan and two 12 V / 9 Ah batteries. With 1500 VA for 900 W of real power, it protects a workstation and its monitors, or a NAS and the switch connecting it to the network.
Three steps to put it into service
1Charge for 6 hours
2Connect USB, install ViewPower
3Plug into the six C13
Delta recommends letting the battery charge for 6 hours before first use. The supplied USB cable then connects the UPS to the PC, and the ViewPower software shuts the computer down cleanly during a long outage. All that remains is to plug the devices into the six C13 outlets — never a laser printer or a scanner, whose inrush current overloads the UPS.
Then it works on its own: its voltage regulator corrects the mains between 170 and 280 V without touching the batteries, and when power fails it switches over in 2 to 6 ms to last 6.8 minutes at half load, the best runtime in the range.
A fan, so a place on the floor
It is the only fan-cooled VX, and you hear it a little more than its smaller siblings: under 45 dBA, against under 40 for the VX 600 and the VX 1000. It is best placed at the foot of the desk or under the worktop, with its grilles clear. On the front, the touch LCD screen keeps the mains and battery status in view.
Same case as the VX 1000 — 130 × 320 × 182 mm —, but two more outlets and 9 Ah batteries instead of 7.
Technical specifications
Technical specifications
Output voltage
230 V ± 10% (battery mode)
Waveform type
Simulated sine wave (battery mode)
Output connections
(6) IEC C13
Input voltage
230 V
Input frequency
45 - 65 Hz
Input connections
1 IEC C14 inlet (mains cord included)
Voltage range
170 - 280 V (at full load)
Automatic voltage regulation (AVR)
Built-in AVR: corrects voltage dips and surges without switching to battery
Battery type
Sealed lead-acid, 2 x 12 V / 9 Ah
Battery management
Automatic recharge even when the UPS is off; automatic restart when power returns
Typical recharge time
6 to 8 hours to 90% charge
Interface port
1 USB port
User interface
LCD touch screen
Audible alarm
Yes: battery mode, low battery, overload, fault
Power management software
ViewPower (Delta): automatic shutdown and remote control
Weight (kg)
10.4 kg
Dimensions (W x D x H) (mm)
130 x 320 x 182 mm
Technology
Line Interactive
Power (VA)
1,500 VA
Technical specifications (continued)
Voltage stabiliser
Yes
Box contents
UPS · Mains power cord · IEC 10 A output cord · USB cable · Quick installation guide
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How much runtime does the Delta Agilon VX 1500 offer?
About 6.8 minutes at half load, i.e. 450 W connected, the best runtime of the VX range. That is enough time to save your work and shut the computer down cleanly, which the ViewPower software can do on its own over the USB port. With a lighter load the runtime gets longer.
Which devices can be connected to the Delta Agilon VX 1500?
Up to 6 devices with computer power cords: its outlets are IEC C13, the format used by desktop PCs, monitors, switches, NAS and servers. Never plug in a laser printer or a scanner: their inrush current overloads the UPS. With 900 W of real power, it backs up for example a workstation and two monitors, or a NAS with its switch.
What is the difference between the Delta VX 1500 and the VX 1000?
The VX 1500 rises to 1500 VA / 900 W versus 1000 VA / 600 W, goes from 4 to 6 C13 outlets and uses two 12 V / 9 Ah batteries instead of 7 Ah. It adds a cooling fan, hence a noise level under 45 dB versus under 40 dB, in the same 130 × 320 × 182 mm case.
Is the Delta Agilon VX 1500 noisy?
A little more than the other VX models: it is the only one in the range with a fan, and its noise level stays under 45 dB. On a desk, preferably place it on the floor or under the worktop, leaving air around its ventilation grilles.
Can the Delta Agilon VX 1500 shut my computer down by itself?
Yes. Connect its USB port to the PC with the supplied cable and install Delta's ViewPower software: during a prolonged outage, it triggers an automatic, clean shutdown of the computer before the battery runs out, and lets you monitor the UPS remotely.
What is in the box of the Delta Agilon VX 1500?
The UPS, a mains power cord, an IEC 10 A output cord, a USB cable and a quick installation guide. Other devices connect with their own C13-plug cords, the standard format for PCs and monitors.
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Comfortable runtime for a full workstation, long enough to save everything before shutdown.
•Runtime: around 42 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
Automatic voltage regulator (AVR) that protects the battery from current fluctuations. Comfortable runtime for a PC and its accessories, long enough to save and shut down cleanly.
Automatic voltage regulation (AVR) and a status LCD screen, in a compact tower format. USB and RS-232 ports for the automatic, clean shutdown of a workstation, a server or a small network.
•Automatic voltage regulation (AVR) — corrects fluctuations without drawing on the battery
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime for a powerful workstation, long enough to save everything.
Professional UPS for a network rack, with pure sine wave output and a compact, shallow format. Intelligent battery management that extends their service life.
•1050 W genuinely usable
•Runtime around 13 minutes at half load (8 minutes at 70%)
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a demanding workstation.
Automatic voltage regulation (AVR) that protects the battery from current fluctuations. French outlets for plugging your equipment in directly, without an adapter.
Built-in voltage regulator and overload circuit breaker — protects your devices without needlessly drawing on the battery. Around 5 minutes of runtime at half load.
Automatic voltage regulator (AVR) that absorbs voltage dips and surges — a real asset where the electricity network is unstable. French outlets, plug in directly with no adapter.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a workstation and its peripherals.