Delta Power Solutions Amplon N 2K Online UPS - 1800 W / 2000 VA - 6 C13 + 1 C19 Outlets (UPS202N2000B035)
An online double-conversion tower UPS for a server or a small rack: 1800 W of pure sine wave power, no transfer time, 13 minutes at half load and an input tolerated from 80 to 280 V.
2000 VA / 1800 W, online double conversion
Pure sine wave, zero transfer time
Runtime: 13 min at half load, 4.5 min at full load
6 C13 outlets and 1 C19 16 A outlet
80 to 280 V input, generator compatible
Efficiency up to 93%
LCD screen, USB port and UPSentry 2012 software
MINI slot for an optional SNMP, relay or Modbus card
An online double-conversion UPS for a server or a small rack: pure sine wave, zero transfer time and 1800 W of real power. Technology: power is rebuilt continuously; your equipment never sees the outages, noise or fluctuations of the grid. Power: 2000 VA / 1800 W (power factor 0.9), on 4 internal 12 V / 9 Ah batteries. Runtime: 13 min at half load, 4.5 min at full load. Outlets: 6 C13 outlets and 1 C19 16 A outlet for power-hungry equipment. Management: LCD screen, USB port, UPSentry software and an SNMP card slot (optional card). Very wide input range (80 to 280 V) and generator compatible: the safe choice on an unstable grid, ideal for example for a server, a NAS, a switch or a critical workstation.
In double conversion, the UPS turns mains power into direct current, then rebuilds a clean alternating current: in normal operation, your equipment is powered by the UPS alone. In a tower just 190 mm wide, it delivers 1,800 W from four internal batteries and keeps running on mains power when the voltage drops as low as 80 V, at half load.
1,800 real watts, not just 2,000 VA
1,800 Wusable from 2,000 VA, power factor 0.9
80 Vlowest voltage held on mains, at half load
93 %efficiency in double conversion
A UPS is labelled in VA, but it is the watts that tell you what you can plug in. With a power factor of 0.9, its 2,000 VA give 1,800 W; at a factor of 0.8, the same label would give only 1,600. Those 200 W are headroom for adding a device.
On a weak line it stays on mains: full load from 175 to 280 V, and down to 80 V by bringing the accepted load down to half. The batteries are kept for real outages.
Efficiency reaches 93% in double conversion and stays at 91% at half load: less energy lost as heat in the room. On the input side, a power factor above 0.99 and harmonic distortion below 3% spare the electrical installation, generator included.
The screen tells you how much time is left
The display shows input and output voltage and frequency, load as a percentage, in kVA and in kW, battery capacity and voltage, temperature and, during an outage, the estimated remaining backup time. Two five-segment bars track load and battery. Holding a button for 3 seconds starts a 10-second battery test: the screen reads PAS when all is well, FAL otherwise. In setup mode you choose the output voltage and frequency, the bypass range, the buzzer and the overload alarm.
Four states at a glance
Each one lights its own icon on the screen, so you always know where the power feeding your equipment comes from.
StandbyPlugged into the mains but not yet started, the UPS charges its batteries.
OnlinePower flows through the UPS, which rebuilds it continuously and keeps the batteries charged.
BypassEquipment is connected directly to the mains; the batteries keep charging.
BatteryWhen power fails, the batteries take over without interruption, long enough to shut down cleanly or wait for the generator.
Two outputs and a heavy-duty input at the back
Six C13 outlets form the first output and one C19 outlet the second, reserved for the most power-hungry device. The UPS connects through a C20 inlet protected by a 20 A breaker, with the 16 A cord supplied. At the top, the MINI slot takes an optional SNMP, relay, Modbus or TVSS card, next to the USB port; two fans exhaust heat at the rear.
Before you switch it on: leave 15 cm clear around the UPS, plug it into an earthed outlet without an extension cord, and keep output cables under 10 m. If it comes from a cold room, wait one hour before turning it on. Rated C2 for electromagnetic compatibility, it may interfere with radio reception in a home.
Beyond 1,800 W to protect, the Amplon N 3K goes up to 2,700 W in the same 190 × 390 × 325 mm cabinet.
The right model for what you protect
Above 1,800 W, the Amplon N 3K takes over in the same cabinet. For a 19-inch rack, or to add an external battery pack, the Amplon RT 2K fits in 2U. For a single PC and its monitor, a line-interactive unit such as the Agilon VX 1000 is enough. Delta's UPS range runs from 600 VA to 4,000 kVA, and its manufacturing system is certified ISO 9001 and ISO 14001.
Technical specifications
Technical specifications
Output voltage
220/230/240 V ± 2% (linear load)
Waveform type
Pure sine wave
Output harmonic distortion
< 3% at linear load
Output connections
(6) IEC C13 + (1) IEC C19
Input voltage
220/230/240 V
Input frequency
50/60 Hz ± 10 Hz
Input connections
1 IEC C20 inlet (16 A input cord included)
Voltage range
80 - 280 V (175 - 280 V at full load, 80 - 175 V between 50 and 100% load)
Battery type
Sealed lead-acid, 4 x 12 V / 9 Ah (48 V)
Battery management
Intelligent charge management; cold start on battery
Typical recharge time
4 hours to 90% charge
Interface port
1 USB port
User interface
LCD screen and LED indicators
Audible alarm
Yes, beeper can be muted from the panel
Power management software
UPSentry 2012 (Delta)
Weight (kg)
18.6 kg
Dimensions (W x D x H) (mm)
190 x 390 x 325 mm
Technology
On-line
Power (VA)
2,000 VA
Voltage stabiliser
Yes
Box contents
UPS · 16 A input cord · 10 A output cord · 16 A output cord · User manual
Technical specifications (continued)
Preinstalled batteries
Yes, internal batteries
Communication card slot
1 MINI slot for an SNMP, relay, Modbus or TVSS card (optional, not included)
Transfer/switching time
0 ms (continuous double conversion)
Cold start
Yes
Bypass
Internal automatic bypass
Audible noise
< 48 dBA
Power factor (ratio)
0.9
Crest factor
3:1
Input power factor
> 0.99 (full load)
Output frequency
50/60 Hz ± 0.05 Hz
Phase (output/input)
Single-phase / Single-phase
Overload capacity
< 105% continuous; 105 to 125% for 1 minute; 125 to 150% for 30 seconds
Double-conversion efficiency
Up to 93%
Output type
C13 outlets
Power (W)
1,800 W
Runtime
13 min at half load; 7 min at 75% load; 4.5 min at full load
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How much runtime does the Delta Amplon N 2K UPS offer?
About 13 minutes at half load, 7 minutes at 75% load and 4.5 minutes at full load (1800 W). That is enough time to finish a task and shut the servers down cleanly, or to hold until a generator starts. This model does not accept an external battery pack: for more runtime, you need a model with extendable batteries.
Why choose the online Amplon N 2K rather than a line-interactive UPS?
Because it rebuilds the power continuously: your equipment is powered by the UPS, never directly by the grid. No transfer time when power fails, a pure sine wave and an output voltage held within ± 2%, even when the mains varies from 80 to 280 V. It is the protection expected for a server or critical equipment.
Which equipment can be connected to the Delta Amplon N 2K?
Six devices on its IEC C13 outlets, the format of servers, NAS, switches and PCs, plus one power-hungry device on the 16 A C19 outlet. A 10 A output cord and a 16 A output cord are included. The UPS itself connects to the mains with its 16 A input cord, on a wall socket rated for that current.
Can the Amplon N 2K be monitored remotely?
Yes. Through its USB port and the UPSentry 2012 software, it triggers the automatic shutdown of servers and tracks the battery status. Its MINI slot accepts an optional SNMP card for network monitoring, a relay contact card or a Modbus card for building management.
Is the Delta Amplon N 2K compatible with a generator?
Yes. Its 80 to 280 V input range and its 50/60 Hz ± 10 Hz frequency tolerance let it accept power from a generator without constantly switching to battery. While the generator starts, its batteries keep the equipment running.
How many watts can you plug into the Amplon N 2K?
Up to 1,800 W in total. Its power factor of 0.9 makes 90% of its 2,000 VA usable, where a UPS with a factor of 0.8 would stop at 1,600 W. Add up the watts printed on each device: the further the total stays below 1,800 W, the longer the runtime, from 4.5 minutes at full load to 13 minutes at half load.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
A 1500 VA / 1500 W Smart-UPS SRT online UPS in 2U rack format, delivered with its NMC 3 network management card and rails. Pure sine wave output, six C13 outlets in two controllable groups, swappable battery and runtime expandable with external packs.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
11 199 DHincl. VAT11 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•1500 VA / 1500 W, double-conversion online
•NMC 3 network card pre-installed
•6 C13 outlets in 2 controllable groups
In stock
23 399 DHincl. VAT23 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•2000 VA / 1800 W, double-conversion online
•2U rack: 438 × 462 × 86 mm, 18.8 kg
•4 IEC C13 outlets, C14 inlet
In stock
11 999 DHincl. VAT11 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
5 399 DHincl. VAT5 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
6 C13 outlets, the format used by computer and server power cords, all battery-backed