Delta Power Solutions Amplon RT 2K Online Rack/Tower UPS - 1800 W / 2000 VA - 6 C13 + 1 C19 Outlets (UPS202R2RT2B035)
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
2000 VA / 1800 W, online double conversion
2U rack or tower, brackets and rail kit included
Pure sine wave, zero transfer time
Runtime: 7 min at 75% load
Extendable with an optional 48 V Delta external battery pack
Hot-swappable internal batteries
6 C13 outlets in two groups and 1 C19 16 A outlet
Efficiency up to 94% online, up to 97% in ECO mode
An online double-conversion UPS for a server or network rack, in 2U rack or tower format: pure sine wave, hot-swappable batteries and rail kit included. Power: 2000 VA / 1800 W (power factor 0.9). Runtime: 7 min at 75% load, extendable with an optional Delta external battery pack. Outlets: 6 C13 outlets in two groups and 1 C19 16 A outlet; secondary loads can be cut on battery to extend the runtime of essential equipment. Management: swivelling LCD screen, USB and RS-232, remote emergency power off and a SMART slot for an SNMP card. Efficiency: up to 94% in online mode, up to 97% in ECO mode. The core of the Amplon RT range (18 kg, 432 mm deep), ideal for example for a server, a rack NAS and the switches of a rack.
A server in an air-conditioned room does not have the needs of a switch at the end of an unreliable line. The Amplon RT 2K picks its operating mode from its front panel: full double conversion, energy saving when the mains is clean, or a fixed output frequency for imported equipment.
1,800 usable watts, even on a weak line
1,800 Wusable from 2,000 VA, power factor 0.9
120 Vlowest voltage held on mains, at 70% load
50 °Cin operation, power reduced to 80% above 40 °C
A UPS is labelled in VA, but it is the watts that tell you what you can plug in. With a power factor of 0.9, its 2,000 VA give 1,800 W; at a factor of 0.8, the same label would give only 1,600. Those 200 W are headroom for a growing rack.
When the mains sags, it stays on the grid: full load from 175 to 280 V, and down to 120 V while keeping 70% of the load. The batteries are kept for real outages, which spares them.
In a technical room without air conditioning it runs up to 50 °C, and it reports a failed fan. Its internal batteries are hot-swappable, with the equipment still powered.
Five modes, one unit
All are selected from the front panel, without software.
Online
The default mode: power is rebuilt continuously, within ± 1% voltage and ± 0.05 Hz, and switching to battery cuts nothing. Efficiency up to 94%.
ECO
To enable on a site with stable mains: as long as the voltage stays within ± 10% and the frequency within ± 5 Hz, the grid feeds the equipment and efficiency rises up to 97%. Beyond that, the UPS takes over immediately.
Bypass
The equipment runs directly on the mains while the batteries recharge; it is also the fallback, in online operation, above 150% load.
Battery
When power fails, the batteries take over without interruption; the buzzer beeps every two seconds, then every half second when the reserve runs low.
Converter
The output is locked at 50 Hz or 60 Hz, whatever the grid frequency. The bypass is then disabled: if the UPS stops, the output stops with it.
A C19 outlet for the power-hungry device
Next to the six C13 outlets in two groups, a C19 outlet alone accepts up to 9 A: that is where the server or storage array with a 16 A cord plugs in. The UPS connects through a C20 inlet protected by a 15 A breaker, with the 16 A input cord included.
The full rear panel, from the Delta manual.The outputs up close: the C19 on the left, the LOAD 1 and LOAD 2 groups on the right.On top the UPS, below the 48 V external battery pack, sold as an option.
The battery test starts from the front panel. Three seconds on the ON button, one beep, and the UPS runs ten seconds on battery to check that it holds; UPSentry 2012 software can also schedule it at regular intervals.
The right model for what you protect
Under 900 W in a rack: the Amplon RT 1K, which is shallower. Up to 2,700 W: the Amplon RT 3K. Without a rack, next to a server: the Amplon N 2K tower. Delta's UPS range runs from 600 VA to 4,000 kVA, and its manufacturing system is certified ISO 9001 and ISO 14001.
Technical specifications
Technical specifications
Output voltage
200/208/220/230/240 V ± 1% (linear load)
Waveform type
Pure sine wave
Output harmonic distortion
< 3% at linear load
Output connections
(6) IEC C13 in 2 groups of 3 (LOAD 1 / LOAD 2), non-critical loads can be shed + (1) IEC C19
Input voltage
200/208/220/230/240 V (200 and 208 V with derating to 90%)
Input frequency
40 - 70 Hz (50/60 Hz ± 10 Hz)
Input connections
1 IEC C20 inlet, 15 A input circuit breaker
Voltage range
120 - 280 V (175 - 280 V at full load, 120 - 175 V between 70 and 100% load)
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Can the Amplon RT 2K be installed in a 19-inch rack?
Yes. It takes 2U in a 19-inch rack, with its mounting brackets and rail kit included in the box; allow 432 mm of depth. It can also stand upright in tower format with the optional Delta tower stand kit; its LCD screen swivels to stay readable in both positions.
How much runtime does the Delta Amplon RT 2K offer?
About 7 min at 75% load with its internal batteries. To last longer, it connects to an optional Delta 48 V external battery pack (same 2U format), which can be added or removed without powering down the equipment. Cutting secondary loads on battery also extends the runtime of essential devices.
Can the batteries of the Amplon RT 2K be replaced without shutting everything down?
Yes, its internal batteries are hot-swappable: the equipment stays powered during the intervention. They are sealed, maintenance-free 12 V / 9 Ah lead-acid batteries; replacement must be done or supervised by a qualified technician, using the same number and type of batteries.
How can the Delta Amplon RT 2K be monitored?
Through its USB or RS-232 port with the UPSentry 2012 software: automatic server shutdown, event log, battery self-test and remaining-time estimate. Its SMART slot accepts an optional SNMP card for network monitoring, a relay card or a Modbus card, and a REPO contact allows remote emergency power off.
What does the ECO mode of the Amplon RT 2K do?
It raises efficiency from 94% to 97%. As long as mains voltage and frequency stay within ± 10% and ± 5 Hz of their nominal values, the equipment is powered by the grid; beyond that, the UPS immediately takes it back in double conversion. It is enabled from the panel, and is best kept for sites where power is stable.
How many watts can you plug into the Amplon RT 2K?
Up to 1,800 W in total. Its power factor of 0.9 makes 90% of its 2,000 VA usable, where a UPS with a factor of 0.8 would stop at 1,600 W. Add up the watts printed on each device: at 75% load, its internal batteries last about 7 minutes.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
A 1500 VA / 1500 W Smart-UPS SRT online UPS in 2U rack format, delivered with its NMC 3 network management card and rails. Pure sine wave output, six C13 outlets in two controllable groups, swappable battery and runtime expandable with external packs.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
An online double-conversion 2U rack or tower UPS for a network rack: 900 W of pure sine wave power, hot-swappable batteries, runtime extendable with an external pack and rail kit included.
An online double-conversion tower UPS for a server or a small rack: 1800 W of pure sine wave power, no transfer time, 13 minutes at half load and an input tolerated from 80 to 280 V.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•1000 VA / 900 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
7 416 DHincl. VAT7 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•2000 VA / 1800 W, online double conversion
•Pure sine wave, zero transfer time
•Runtime: 13 min at half load, 4.5 min at full load
In stock
8 599 DHincl. VAT8 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
11 199 DHincl. VAT11 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.