APC Easy UPS SRV SRV2KRI-E Online UPS - 1800 W / 2000 VA - 2U Rack - 4 C13 Outlets
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
A rack-mount online UPS to protect a server, a NAS or the core of a network: double conversion, 2000 VA / 1800 W and only 2U in the rack. Voltage: pure sine wave output regenerated continuously, ± 1 % static, with no transfer time Input: accepts 180 to 285 V at full load, down to 110 V at 40 % load, before drawing on the battery Outlets: 4 C13 outlets, C14 inlet and Schuko-to-C13 cord supplied Management: LCD screen, USB and RS-232 ports, network card slot, server shutdown via PowerChute Battery: 48 V / 9 Ah module APCRBCV201, 4-hour recharge The -E version of the 2 kVA rack-mount Easy UPS SRV: 1800 W usable, mounting rails to be ordered separately.
Yes : Pure sine wave: suits servers and sensitive power supplies
Automatic shutdown
Yes : Yes, over USB: the PC or NAS shuts down cleanly
Form factor
2U rack
Runtime with your load
Tell us what you want to protect: this page works out how long this UPS holds during a power cut.
≈ 27 min
for 430 W, that is 24% of its power
Tower server
400 W
1
Rack server
600 W
0
NAS
60 W · 2 to 4 drives
0
Network switch
30 W
1
PoE switch
150 W · powered cameras included
0
Router, modem or access point
20 W
0
Video recorder (NVR/DVR)
60 W
0
High-performance desktop PC
400 W · dedicated graphics card
0
It fits.
It still has headroom for one more device.
Worked out from the points published by the manufacturer: 60 min at 180 W ; 25,5 min at 450 W ; 10,9 min at 900 W ; 5,7 min at 1 350 W ; 3,1 min at 1 800 W. New battery; runtime drops as it ages.
Description
APC Easy UPS On-Line · Reference SRV2KRI-E
Fresh power, continuously, in 2U of rack space.
A 2000 VA / 1800 W double-conversion online UPS to protect a server, a NAS or the switches in a rack: the output voltage is recreated at all times, with no switchover time during an outage.
1800 Wfor 2000 VA
0 mstransfer time
88 %efficiency at full load
2Uof rack height
An unstable grid does not get through
Mains power is first converted to DC, then the UPS regenerates a pure 230 V sine wave, regulated to within 1 %; 220 or 240 V can also be programmed. It accepts an input of 180 to 285 V at full load, and down to 110 V when the load stays below 40 %, before calling on its 48 V / 9 Ah battery.
At the back, everything a rack needs
C14 inlet and circuit breaker on the left, card slot in the middle, four C13 outlets on the right.
Four battery-backed C13 outlets, a C14 inlet with a 16 A circuit breaker, a USB port, an RS-232 port and an emergency power off terminal. The Intelligent Card Slot stays free for a network management card. With the supplied USB cable and PowerChute Serial Shutdown software, the server shuts itself down before the runtime runs out.
The -E generation, at 1800 W
Compared with the 1600 W SRV2KRI, this version gains 200 usable watts at the same apparent power. It has an LCD control screen, battery start without mains power and a Green mode, which sends grid power straight to the equipment as long as it stays within the set limits.
The rails are not in the box: only the front brackets and their screws are supplied. Plan a shelf in the rack, or the SRVRK1 rail kit, to carry the 18.8 kg.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
What is the difference between the SRV2KRI-E and the SRV2KRI?
Usable power: the SRV2KRI-E delivers 1800 W for 2000 VA, the previous version 1600 W. Both are 2U rack-mount online UPSs with four C13 outlets. The -E model states 945 J of surge protection and comes with a 1.5 m Schuko-to-C13 input cord, without mounting rails.
Are rack mounting rails supplied?
No: only the two front brackets and their eight screws are in the box. To carry its 18.8 kg, you need either a shelf already installed in the rack or the SRVRK1 rail kit, offered as an option by APC. It is installed at the bottom of the rack, below the equipment it powers.
Can it shut down a server properly during an outage?
Yes: with the supplied USB or RS-232 cable and the PowerChute Serial Shutdown software, downloaded from the manufacturer, the UPS triggers the operating system shutdown before the runtime ends. The software installs on a 64-bit system. USB and RS-232 cannot be used at the same time.
What does double-conversion online mean for my equipment?
A continuously regenerated voltage: the UPS converts mains power to DC and then recreates a pure 230 V sine wave, regulated to ± 1 %. There is therefore no transfer time during an outage, and grid variations, from 180 to 285 V at full load, do not reach the connected devices.
Is the battery replaceable?
Yes, with an APCRBCV201 48 V / 9 Ah module, to be changed at the latest every five years or as soon as the UPS signals it. Its service life is three to five years and shortens with heat and frequent outages. On delivery, the battery is disconnected: it is connected before the first power-up.
Can the UPS be started without mains power?
Yes, thanks to cold start: pressing the power button once lights up the screen, a second press powers the equipment from the battery. This is useful to restart a server during a prolonged outage, within the limits of the available runtime.
Short 438 mm depth for small racks: power continuously regenerated with zero transfer time, 4 C13 outlets, hot-swappable batteries and automatic server shutdown over USB or RS232.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
An online double-conversion tower UPS for a server or a small rack: 1800 W of pure sine wave power, no transfer time, 13 minutes at half load and an input tolerated from 80 to 280 V.
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•4 C13 outlets, the format used by computer and server cords
In stock
5 399 DHincl. VAT5 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
11 699 DHincl. VAT11 699,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
C13 outlets: the format of computer and server power cords
In stock
14 799 DHincl. VAT14 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime 8.5 min at half load, 3 min at full load
In stock
33 255,36 DHincl. VAT33 255,36 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•2000 VA / 1800 W, online double conversion
•Pure sine wave, zero transfer time
•Runtime: 13 min at half load, 4.5 min at full load
In stock
8 599 DHincl. VAT8 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime 11 minutes at half load (3000 W)
•Runtime 7 minutes at 70% load (4200 W)
•Height 4U in a rack
In stock
25 599 DHincl. VAT25 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 7 minutes at half load (5000 W)
•4U height in a rack
In stock
31 699 DHincl. VAT31 699,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed