APC BX2200MI-GR Line-Interactive UPS 2.2 kVA 1200 W 4 AC outlet(s) (BX2200MI-GR)
Protects a demanding workstation: the voltage regulator automatically corrects drops and rises in the mains without drawing on the battery. It also protects the telephone line against surges.
Automatic voltage regulator (AVR)
Battery life around 8 minutes at half load
4 FR outlets (Schuko)
Protection of the telephone line (RJ11) against surges
USB port for an automatic, clean shutdown (PowerChute software)
Audible noise 40 dBA
Ref.: BX2200MI-GR
Out of stock
1/7
3 899,00 DHincl. VAT
Out of stock
Product overview
A powerful desktop UPS to protect a complete workstation: line-interactive with automatic voltage regulation (AVR), 2200 VA / 1200 W and sine-wave output. Technology & protection: it switches to battery during a power cut, absorbs surges and automatically corrects voltage dips and spikes without drawing on the battery — a real advantage wherever the mains supply is unstable. Power: 2200 VA for 1200 W of usable power — a complete workstation, several monitors or even a small server. Outlets: 4 French-style (Schuko) outlets — plug in directly, no adapter needed. Ideal, for example, for a demanding workstation, a point-of-sale system or a small server. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the BX2200MI-GR run on battery?
8 and a half minutes at half load, i.e. 600 W, and one minute at full load, at 1200 W. The gap shows the value of keeping some headroom: the lighter the load, the longer the runtime.
Do the BX2200MI-GR outlets take a French plug?
Yes, the four outputs are type F, the type used for French and German sockets: you plug your devices in directly, with no adapter or IEC cord. The input cord is 1.2 m long and ends in the same plug.
Why do 2200 VA give only 1200 W?
Because the input power factor is 0.54: only just over half of the apparent power is usable. It is indeed 1200 W that you should compare with the combined consumption of your workstation.
Over what voltage range does the AVR on the BX2200MI-GR correct?
Between 140 and 300 V: the regulator boosts low voltages and reduces high voltages without discharging the battery, which stays full for real power cuts. The output voltage is held at 230 V, to within 10%.
Can the BX2200MI-GR shut down the PC by itself?
Yes, through its USB Type-B port: connected to the computer, it triggers a clean system shutdown when the battery runs low, using the PowerChute Personal Edition software. Audible alarms also signal any change of status.
Does the BX2200MI-GR battery give a warning before it fails?
Yes: a periodic self-test checks its condition and an early warning signals an impending failure, which leaves time to replace it before it breaks down. A full recharge takes 8 hours.
Does the BX2200MI-GR also protect the data line?
Yes, surge protection is provided for the data line, in addition to the power outlets. On the electrical side, energy absorption reaches 273 joules and the response time is 6 milliseconds.
How much space does the BX2200MI-GR take up?
140 mm wide, 390 deep, 190 high, weighing 12.3 kg: a tower format that stands on the floor, under or next to the desk. It is rated at 40 dB, the level of a quiet room.
Is the APC Back-UPS BX2200MI-GR new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It comes with its input cable and its manual, and complies with the CE, IEC 62040-1 and IEC 62040-2 standards. Its lead-acid battery is a sealed, maintenance-free type.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a demanding workstation.
•Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime for a powerful workstation, long enough to save everything.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a workstation and its peripherals.
Protects a demanding workstation or a small server: the voltage regulator corrects drops and surges without draining the battery. Around 9 minutes of runtime at half load.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
A 2200 VA / 1200 W line-interactive UPS for a demanding workstation, two computers or a light network rack. Its four Schuko outlets stay powered during an outage, 4 min at half load, and the AVR corrects voltage deviations without using the battery.
Automatic voltage regulation (AVR) that protects the battery from current fluctuations. French outlets for plugging your equipment in directly, without an adapter.
Compact desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Built-in voltage regulator that corrects drops and surges without drawing on the battery. Battery life of around 10 minutes at half load, quiet operation (40 dB).
A 1600 VA / 900 W line-interactive UPS for a complete workstation: tower, monitor, box and router. Its four Schuko outlets stay powered during an outage, 6 min 45 s at half load, and the AVR corrects voltage deviations without using the battery.
Runtime: around 52 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
•USB port for automatic, clean PC shutdown
In stock
3 469 DHincl. VAT3 469,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a demanding workstation.
•Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
Automatic voltage regulation (AVR) that protects the battery from current fluctuations. French outlets for plugging your equipment in directly, without an adapter.
Protects a demanding workstation or a small server: the voltage regulator corrects drops and surges without draining the battery. Around 9 minutes of runtime at half load.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Stabilises the current and protects a workstation and its peripherals against outages and surges, without drawing on the battery during voltage fluctuations. Around 9 minutes of runtime at half load.
Protects a light computer setup against outages and surges thanks to its built-in voltage regulator. Around 7 minutes of runtime at half load, enough time to save and shut down properly.
Compact desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a workstation and its peripherals.
Tower format for several servers or network equipment: 2100 W usable, 8 C13 outlets + 1 reinforced C19 outlet all battery-backed. Quiet operation (≈ 45 dB).
•Usable power 2100 W
•8 C13 outlets + 1 reinforced C19 outlet, all battery-backed