Built-in voltage regulator and overload circuit breaker — protects your devices without needlessly drawing on the battery. Around 5 minutes of runtime at half load.
Automatic voltage regulator (AVR) — corrects fluctuations without draining the battery
Desktop UPS to protect a workstation and its peripherals: line-interactive with voltage regulation and 1200 VA / 650 W. Technology & protection: it switches to battery the instant the power cuts out, absorbs surges and corrects voltage dips and spikes without drawing on the battery. Power: 1200 VA for 650 W of usable output — a PC, a monitor and their accessories. Runtime: approx. 5 minutes at half load (300 W) — enough time to save and shut down properly. Outlets: 4 FR outlets — plug in directly, no adapter needed. Ideal, for example, for an office workstation, an internet box or a point-of-sale system. Remember to check how much power your equipment draws and to choose the capacity that matches the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How much power can the APC BX1200MI-FR UPS supply?
It delivers 1200 VA / 650 W of usable power — enough to protect, for example, a PC, a monitor and their accessories. Add up the wattage of your devices: it must stay below 650 W.
How long does the BX1200MI-FR UPS last during a power cut?
Runtime depends on the load:
about 5 minutes at half load (300 W)
about 4 minutes at 70% (455 W)
about 1 minute at full load (650 W)
Enough to save your work and shut down properly — it is not designed for working on for long.
How many outlets does the APC BX1200MI-FR UPS have, and what type are they?
4 French outlets (CEE 7/5), for direct connection of your equipment without an adapter.
Are all the UPS outlets protected?
Yes, all 4 outlets are protected (battery backup and surge protection), with a built-in overload circuit breaker.
Does the BX1200MI-FR UPS deliver a pure sine wave?
No, it provides a stepped approximation to a sine wave (pseudo-sine). This suits the vast majority of PCs and office peripherals; however, some very sensitive power supplies or motors may prefer a pure sine wave.
Is the APC BX1200MI-FR UPS battery replaceable?
Yes: a replaceable 12 V sealed lead-acid battery (APC reference RBC175). Its service life is about 3 to 5 years, and a full recharge takes about 8 hours.
Can the BX1200MI-FR UPS be connected to a PC via USB for automatic shutdown?
No: this model has no USB communication port, so there is no automatic shutdown software. It provides protection, with an LED status indicator and an audible alarm in the event of a power cut or overload.
Does the APC BX1200MI-FR UPS correct voltage fluctuations without wearing down the battery?
Yes, thanks to its automatic voltage regulator (AVR): it corrects voltage dips and surges (input range 140–300 V) without switching to battery, which preserves its runtime.
Is the APC BX1200MI-FR UPS noisy?
Its noise level is about 40 dBA, unobtrusive in normal operation. An audible alarm sounds only in the event of a power cut or overload.
Can the UPS be started without mains power (Cold Start function)?
Yes, the “Cold Start” function lets you start up and power a device from the battery even when there is no mains power.
Can the APC BX1200MI-FR UPS be rack-mounted?
No, it is a vertical tower model, not rack-mountable. Dimensions: 19 × 14 × 39 cm, weight 7.6 kg.
Is the APC BX1200MI-FR UPS new and under warranty?
Yes, a new product, with a 2-year warranty (repair or replacement), plus APC's connected equipment protection policy. Your invoice serves as the warranty document. See the datasheet.
The most powerful Agilon VX: 900 W of real power on 6 C13 outlets for a workstation and its monitors or a small network corner. AVR regulator, LCD touch screen and automatic PC shutdown over USB.
•1500 VA / 900 W, line-interactive technology
•6 C13 outlets, the format of computer and monitor cords
•AVR voltage regulator: accepts 170 to 280 V input
Automatic voltage regulator (AVR) that protects the battery from current fluctuations. Comfortable runtime for a PC and its accessories, long enough to save and shut down cleanly.
Protects a computer workstation and its peripherals, with reinforced network/telephone protection up to 1 Gb/s (RJ11/RJ45) and confirmed compatibility with Synology NAS units.
600 W of usable power for a complete computer setup, with a built-in voltage regulator that corrects fluctuations without drawing on the battery. Compact (5.7 kg), plugs in directly without an adapter.
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Comfortable runtime for a full workstation, long enough to save everything before shutdown.
A 1600 VA / 900 W line-interactive UPS for a complete workstation: tower, monitor, box and router. Its four Schuko outlets stay powered during an outage, 6 min 45 s at half load, and the AVR corrects voltage deviations without using the battery.
Stabilises the current and protects a workstation and its peripherals against outages and surges, without drawing on the battery during voltage fluctuations. Around 9 minutes of runtime at half load.
Automatic voltage regulator (AVR) that protects the battery from current fluctuations. French outlets to plug your equipment in directly, with no adapter.
Runtime: around 40 minutes for a PC
•Automatic voltage regulator (AVR) — protects the battery from current fluctuations
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a demanding workstation.
•Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
Automatic voltage regulation (AVR) that protects the battery from current fluctuations. French outlets for plugging your equipment in directly, without an adapter.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a workstation and its peripherals.
Built-in voltage regulator that corrects drops and surges without drawing on the battery. Battery life of around 10 minutes at half load, quiet operation (40 dB).
A 1600 VA / 900 W line-interactive UPS for a complete workstation: tower, monitor, box and router. Its four Schuko outlets stay powered during an outage, 6 min 45 s at half load, and the AVR corrects voltage deviations without using the battery.
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Comfortable runtime for a full workstation, long enough to save everything before shutdown.
Protects a demanding workstation or a small server: the voltage regulator corrects drops and surges without draining the battery. Around 9 minutes of runtime at half load.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Stabilises the current and protects a workstation and its peripherals against outages and surges, without drawing on the battery during voltage fluctuations. Around 9 minutes of runtime at half load.