APC Easy UPS BVX2200LI Line-Interactive UPS - 1200 W / 2200 VA - 6 C19 outlets
Built-in voltage regulator that corrects drops and surges without drawing on the battery. Battery life of around 9 minutes at half load, quiet operation (40 dB).
Automatic voltage regulation (AVR) — corrects variations without draining the battery
Heavy-duty 16 A C19 outlets — for power-hungry equipment
An entry-level UPS to protect a powerful workstation: line-interactive with voltage regulation and 2200 VA / 1200 W. Technology & protection: it switches to battery the moment the power fails, protects against surges and corrects voltage dips and spikes without drawing on the battery. Power: 2200 VA for 1200 W of usable power — a complete workstation, several monitors or even a small server. Runtime: about 9 minutes at half load (600 W) — time to save your work and shut down properly. Outlets: 6 heavy-duty C19 outlets, suited to power-hungry equipment. Quiet operation. Ideal, for example, for a demanding workstation, a graphics workstation or a small server. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the BVX2200LI run on battery?
About 9 minutes at half load, i.e. 600 W, and 5 minutes at 840 W. On the other hand, loaded up to its 1200 W limit, it lasts only one minute: it is best to keep some headroom.
Can I plug a standard computer power cord into the BVX2200LI?
Its six outputs are C19 outlets, designed for power-hungry equipment: they take C20 plugs, which are wider than the C14 plugs on ordinary computer cords. Make sure you have the matching cords for each device.
How does the BVX2200LI connect to the mains?
Through a heavy-duty C20 inlet, with a 1.22 m cord — not the C14 of a desktop UPS. Check that the wall socket and the circuit supplying it can handle the consumption of the whole setup.
Why does 2200 VA only give 1200 W?
Because the power factor is 0.54: barely more than half of the apparent power is usable. It is indeed 1200 W that you should compare with the combined consumption of your workstation or your small server.
What waveform does the BVX2200LI output?
An approximated sine wave, built up in steps, not a pure sine wave. Transfer takes 6 milliseconds typical and 10 maximum, a gap that a computer power supply absorbs without a hitch.
Over what voltage range does the BVX2200LI's AVR correct?
Between 140 and 300 V. Within this range, the automatic regulator brings the voltage back to its normal value without drawing on the battery, which thus stays full for real power cuts and wears out more slowly.
Is the BVX2200LI's battery replaceable?
Yes, under part number APCRBC177. It is a 24 V, 9 Ah sealed lead-acid pack, i.e. 216 VAh, with a stated service life of 2 to 3 years.
Does the BVX2200LI connect to a computer?
No, it has no USB port: its status is shown by LEDs, online or on battery, with an audible alarm when it switches to battery and another when the battery is running out. So there is no automatic shutdown controlled from the computer.
Where should the BVX2200LI be installed, and can it go in a rack?
No, it is not rack-mountable: it is a tower unit that stands on the floor, measuring 140 × 390 × 190 mm and weighing 12.2 kg. Rated at 40 dBA, it stays quiet next to a workstation.
Is the APC Easy UPS BVX2200LI new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 2 years. A full recharge takes 8 hours and surge absorption reaches 273 joules. The datasheet covers the rest.
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime for a powerful workstation, long enough to save everything.
•Runtime: around 52 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a demanding workstation.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a workstation and its peripherals.
Protects a demanding workstation or a small server: the voltage regulator corrects drops and surges without draining the battery. Around 9 minutes of runtime at half load.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
A 2200 VA / 1200 W line-interactive UPS for a demanding workstation, two computers or a light network rack. Its four Schuko outlets stay powered during an outage, 4 min at half load, and the AVR corrects voltage deviations without using the battery.
Automatic voltage regulation (AVR) that protects the battery from current fluctuations. French outlets for plugging your equipment in directly, without an adapter.
Compact desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a computer workstation.
Built-in voltage regulator that corrects drops and surges without drawing on the battery. Battery life of around 10 minutes at half load, quiet operation (40 dB).
A 1600 VA / 900 W line-interactive UPS for a complete workstation: tower, monitor, box and router. Its four Schuko outlets stay powered during an outage, 6 min 45 s at half load, and the AVR corrects voltage deviations without using the battery.
•Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
In stock
4 099 DHincl. VAT4 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime for a powerful workstation, long enough to save everything.
•Runtime: around 52 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Comfortable runtime for a full workstation, long enough to save everything before shutdown.
Automatic voltage regulator (AVR) that protects the battery from current fluctuations. Comfortable runtime for a PC and its accessories, long enough to save and shut down cleanly.
Automatic voltage regulation (AVR) and a status LCD screen, in a compact tower format. USB and RS-232 ports for the automatic, clean shutdown of a workstation, a server or a small network.
•Automatic voltage regulation (AVR) — corrects fluctuations without drawing on the battery
The most powerful Agilon VX: 900 W of real power on 6 C13 outlets for a workstation and its monitors or a small network corner. AVR regulator, LCD touch screen and automatic PC shutdown over USB.
Protects a demanding workstation or a small server: the voltage regulator corrects drops and surges without draining the battery. Around 9 minutes of runtime at half load.
Tower format for several servers or network equipment: 2100 W usable, 8 C13 outlets + 1 reinforced C19 outlet all battery-backed. Quiet operation (≈ 45 dB).
Professional UPS for a network rack, with pure sine wave output and a compact, shallow format. Intelligent battery management that extends their service life.
•1050 W genuinely usable
•Runtime around 13 minutes at half load (8 minutes at 70%)
A 2200 VA / 1200 W line-interactive UPS for a demanding workstation, two computers or a light network rack. Its four Schuko outlets stay powered during an outage, 4 min at half load, and the AVR corrects voltage deviations without using the battery.