APC Easy UPS BVG900I-GR Line-Interactive UPS - 480 W / 900 VA - 2 Schuko outlets
APC Easy UPS line-interactive UPS of 900 VA / 480 W with automatic voltage regulation: 2 backed-up and protected Schuko outlets, switch to battery in 6 ms and 3 min 48 s of runtime at 240 W. Compact 101 mm wide tower, no USB port.
900 VA / 480 W, line-interactive technology
Automatic voltage regulation (AVR) between 170 and 280 V
2 backed-up and protected Schuko outlets
3 min 48 s of runtime at half load (240 W)
Transfer to battery in 6 ms typical, 10 ms maximum
Compact UPS for a more demanding desktop computer, its internet box or a small network device: 900 VA / 480 W, automatic voltage regulation (AVR) and 2 backed-up Schuko outlets. Technology: line-interactive, switches to battery in 6 ms typical, 10 ms at most Runtime: 3 min 48 s at half load (240 W), time to save and shut down Voltage: AVR raises or lowers the mains without drawing on the battery; switches to battery below 170 V or above 280 V Protection: 156 J surge protection and a resettable 7 A input circuit breaker Format: 101 mm wide tower, 4.9 kg, 12 V / 9 Ah battery The same tower as the 700 VA, with 120 W more for a PC and its monitor.
A 900 VA line-interactive UPS for a desktop computer, its monitor or an internet box: two backed-up Schuko outlets, voltage regulation that spares the battery, and a few minutes to save and shut down.
900 VA480 W of usable power
3 min 48 sof runtime at 240 W
6 msto switch to battery
9 Ah12 V lead-acid battery
Voltage dips corrected without the battery
Between 170 and 280 V, automatic voltage regulation raises or lowers the mains voltage before passing it on: a passing dip therefore does not drain the battery. Outside that range, or when the power goes, the UPS switches to battery in 6 ms as a rule, 10 ms at most, and delivers 230 V within 10%.
Two outlets, one circuit breaker
Two Schuko outlets powered by the battery and protected against surges, up to 156 J. The 7 A input circuit breaker can be reset after an overload. The battery connector arrives unplugged for transport: push it into place before switching on for the first time.
120 W more than the 700 VA, in the same tower
The BVG900I-GR keeps the 101 × 300 × 142 mm unit of the BVG700I-GR, but moves from 360 to 480 W and from a 7 Ah to a 9 Ah battery. It weighs 4.9 kg. To plug in four devices, the 1200 VA version moves up to four outlets.
No USB port on this model: no software shuts the computer down for you. During a power cut, four beeps every 30 seconds remind you to save and shut down. The day the battery wears out, it is replaced by an authorised service centre, not by the user.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the APC BVG900I-GR last during a power cut?
APC states 3 min 48 s at half load, i.e. 240 W connected. With fewer devices, the time gets longer; at full load, it becomes very short. This time is for saving your work and shutting the computer down cleanly, not for carrying on working through a long power cut.
Which devices can be plugged into the BVG900I-GR?
A desktop computer and its monitor, or an internet box and a small switch, on its two backed-up Schuko outlets. The total must not exceed 480 W. APC asks you not to use an output cable longer than 2 m between the UPS and the device.
Does the BVG900I-GR shut the computer down automatically?
No. This model has no USB port and no software triggers the computer's shutdown. During a power cut, the UPS gives four beeps every 30 seconds: that is the signal to save and shut down yourself.
What is automatic voltage regulation (AVR) for?
Between 170 and 280 V, the UPS raises or lowers the mains voltage before passing it on to the devices, without drawing on the battery. It only switches to battery outside that range or during a power cut, which spares the battery where the grid often fluctuates.
Can I replace the battery of the BVG900I-GR myself?
No. APC states that the battery of the Easy UPS range is not user-replaceable: the replacement goes through an authorised service centre. Its life is three to five years depending on temperature, humidity and how often power cuts occur.
What is the difference with the BVG700I-GR?
The unit and the two Schuko outlets are the same, but the BVG900I-GR moves from 360 to 480 W of usable power and from a 7 Ah to a 9 Ah battery. Its input circuit breaker is rated 7 A instead of 5 A and it weighs 4.9 kg instead of 4.2 kg.
Automatic voltage regulator (AVR) that stabilises the current without drawing on the battery. French outlets to plug your equipment in directly, with no adapter.
•Runtime: around 14 minutes for a PC
•Automatic voltage regulator (AVR) — stabilises the current without drawing on the battery
•French outlets — plug your equipment in directly, with no adapter
Automatic voltage regulator (AVR) that protects the battery from current fluctuations. French outlets to plug your equipment in directly, with no adapter.
Protects a compact computer workstation: the USB port triggers an automatic, clean shutdown of the PC during an outage. It also protects the telephone/network line (RJ11/RJ45).
A 700 VA / 360 W line-interactive UPS for a desktop computer, an internet box or a small network device. Its two Schuko outlets stay powered during an outage, 4 min 36 s at half load, and the AVR corrects voltage deviations without using the battery.
Protects a compact computer workstation, with reinforced network/telephone protection up to 1 Gb/s (RJ11/RJ45) and confirmed compatibility with Synology NAS units.
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Compact and quiet, designed for a light day-to-day workstation.
Automatic voltage regulation (AVR) that steadies the power without drawing on the battery. Enough runtime to save your work and shut the PC down cleanly during an outage.
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime to save your work and shut the PC down cleanly during an outage.
Stabilises the current and protects a workstation and its peripherals against outages and surges, without drawing on the battery during voltage fluctuations. Around 9 minutes of runtime at half load.