APC Smart-UPS 2 200 VA Line-Interactive UPS Rack/Tower (SMT2200RMI2UNC)
Professional UPS for enterprise servers and network racks, with a built-in network card for remote control. Runtime around 16 minutes at half load, LCD display.
1980 W usable power (2200 VA)
Runtime around 16 min at half load (990 W), 10 min at 70%
8 C13 outlets + 1 reinforced C19 outlet, all battery-backed
Built-in network card (remote control and monitoring)
Pure sine wave output
Multifunction LCD display
Audible noise 55 dB — installation in a technical room recommended
Professional UPS for servers, with remote monitoring: line-interactive with voltage regulation, 2200 VA / 1980 W, rack/tower form factor. Technology & protection: it switches to battery the instant the power cuts out, absorbs surges and continuously corrects voltage fluctuations without drawing on the battery. Power: 2200 VA for 1980 W of usable output — several servers or networking equipment. Runtime: approx. 16 minutes at half load (990 W), 10 minutes at 70%. Outlets: 8 C13 outlets + 1 heavy-duty C19 outlet for power-hungry equipment. Management: built-in network card to control and monitor the UPS remotely — essential in a server room. LCD display: it shows the load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Ideal, for example, for servers or business network racks. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
IEC 320 C20, British BS1363A, Schuko CEE 7 / EU1-16P
Cord length
2 m
Voltage range
160-286 V (adjustable 151-302 V)
Automatic voltage regulation (AVR)
AVR (automatic voltage regulation), input range 160 - 286 V (adjustable 151 - 302 V)
Battery type
Sealed maintenance-free lead-acid battery with suspended electrolyte: leakproof
Typical recharge time
3 hours
Interface port
1 RJ-45 10/100 Base-T port, 1 RJ-45 serial port, 1 USB port, 1 SmartSlot
User interface
LED indicators (mains, battery, replace battery, overload) and multifunction LCD console
Audible alarm
Alarm when switching to battery, distinct low-battery alarm, configurable delays
Weight (kg)
42.22 kg (49.63 kg with packaging)
Dimensions (W x D x H) (mm)
480 x 683 x 86 mm
Technology
Line Interactive
Technical specifications (continued)
Power (VA)
2,200 VA
Voltage stabiliser
Yes
Box contents
Software CD · Documentation CD · Installation guide · Rack-mount rails and screws · RS-232 cable for Smart-UPS connection · Temperature probe · USB cable
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Is the network card built into the SMT2200RMI2UNC?
Yes, a network card is built in — that is what the letters “NC” in the reference indicate. Control and monitoring are carried out remotely over the network, with no accessory to order.
How long does the SMT2200RMI2UNC run on battery?
16 minutes at 50% load, i.e. 990 W, and 10 minutes at 70%, i.e. 1386 W. Enough to shut down a server rack cleanly, without rushing.
Are all the outlets on the SMT2200RMI2UNC battery-backed?
Yes: eight C13 outlets, one heavy-duty C19 outlet and three IEC jumpers. The inlet accepts a C20, Schuko or UK connection — no hardwiring needed.
How can a line-interactive UPS claim 1980 W for 2200 VA?
Thanks to a power factor of 0.9, which makes almost all of the apparent power available in watts. A desktop UPS at 0.54 would offer only 1190 for the same stated rating.
Where should the SMT2200RMI2UNC be installed?
In an equipment room: it is rated at 55 dBA, which is clearly audible in a workspace. Allow for 42.2 kg: rack installation takes two people, at the bottom of the cabinet.
Is the output a pure sine wave?
Yes, the output is a pure sine wave, synchronised with the mains at 50/60 Hz ± 3 Hz. That is what the power-factor-corrected power supplies of servers require.
Does the SMT2200RMI2UNC install in a rack or as a tower?
Both: it is a convertible rack/tower chassis. As a tower, it takes up less floor space than a conventional UPS of the same power; in a rack, it goes at the bottom of the cabinet because of its weight.
Is the APC Smart-UPS SMT2200RMI2UNC new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for a period of 2 years. It can also be managed locally via a USB or RS-232 port, and displays its status on a multifunction LCD screen. The datasheet covers the rest.
Tower format for several servers or network equipment: 2100 W usable, 8 C13 outlets + 1 reinforced C19 outlet all battery-backed. Quiet operation (≈ 45 dB).
•Usable power 2100 W
•8 C13 outlets + 1 reinforced C19 outlet, all battery-backed
A high-end professional UPS with a high power factor (0.9): almost all of the stated power is usable in watts. Convertible rack or tower format, pure sine wave output.
A professional UPS with an excellent power factor (0.9): almost all of the stated power stays usable in watts. Convertible rack or tower format, pure sine wave output.
•1980 W genuinely usable output — high power factor (0.9)
•Runtime around 7 minutes at half load (4 minutes at 70%)
Professional UPS for a network rack, with pure sine wave output and a compact, shallow format. Intelligent battery management that extends their service life.
•1050 W genuinely usable
•Runtime around 13 minutes at half load (8 minutes at 70%)
A professional UPS for a network rack, with pure sine wave output and a compact, shallow-depth format. Intelligent battery management that extends their service life.
•700 W genuinely usable output
•Runtime around 12 minutes at half load (8 minutes at 70%)
Automatic voltage regulation (AVR) and a status LCD screen, in a compact tower format. USB and RS-232 ports for the automatic, clean shutdown of a workstation, a server or a small network.
•Automatic voltage regulation (AVR) — corrects fluctuations without drawing on the battery
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a demanding workstation.
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime for a powerful workstation, long enough to save everything.
Desktop UPS with automatic voltage regulation: it corrects drops and surges in the mains without drawing on the battery. Very quiet operation, designed for a workstation and its peripherals.
•
•High power factor (0.9) — almost all the power genuinely usable in watts
•Runtime around 10 minutes at half load (6 minutes at 70%)
•USB port and RS232 serial port for automatic system shutdown
In stock
12 599 DHincl. VAT12 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•8 C13 outlets + 1 C19 outlet for power-hungry equipment
In stock
11 499 DHincl. VAT11 499,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
8 C13 outlets (the format used by computer and server power cords)
In stock
9 599 DHincl. VAT9 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•8 C13 outlets (the format used by computer and server power cords)
In stock
8 595 DHincl. VAT8 595,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
8 C13 outlets, C14 input, compact tower format
•USB + RS-232 port for automatic, clean shutdown
In stock
8 299 DHincl. VAT8 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime around 7.5 minutes at half load (900 W), 4 minutes at 75%
•All outlets are battery-backed
•RS232 and USB ports for automatic system shutdown
In stock
6 190 DHincl. VAT6 190,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
In stock
4 099 DHincl. VAT4 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime: around 52 minutes for a PC
•Automatic voltage regulation (AVR) — protects the battery from power fluctuations
•USB port for automatic, clean PC shutdown
In stock
3 595 DHincl. VAT3 595,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime around 9 minutes at half load (5 minutes at 70%)
•8 French outlets, 4 of them battery-backed and 4 surge-protected
•USB port for automatic PC shutdown (Eaton UPS Companion software included)
A professional UPS with an excellent power factor (0.9): almost all of the stated power stays usable in watts. Convertible rack or tower format, pure sine wave output.
•1980 W genuinely usable output — high power factor (0.9)
•Runtime around 7 minutes at half load (4 minutes at 70%)
•8 C13 outlets + 1 C19 outlet for power-hungry equipment
A high-end professional UPS with a high power factor (0.9): almost all of the stated power is usable in watts. Convertible rack or tower format, pure sine wave output.
Tower format for several servers or network equipment: 2100 W usable, 8 C13 outlets + 1 reinforced C19 outlet all battery-backed. Quiet operation (≈ 45 dB).
•Usable power 2100 W
•8 C13 outlets + 1 reinforced C19 outlet, all battery-backed
Professional UPS for a network rack, with pure sine wave output and a compact, shallow format. Intelligent battery management that extends their service life.
•1050 W genuinely usable
•Runtime around 13 minutes at half load (8 minutes at 70%)
A professional UPS for a network rack, with pure sine wave output and a compact, shallow-depth format. Intelligent battery management that extends their service life.
•700 W genuinely usable output
•Runtime around 12 minutes at half load (8 minutes at 70%)
Automatic voltage regulation (AVR) that absorbs voltage dips and surges without drawing on the battery. Comfortable runtime for a powerful workstation, long enough to save everything.
Automatic voltage regulation (AVR) and a status LCD screen, in a compact tower format. USB and RS-232 ports for the automatic, clean shutdown of a workstation, a server or a small network.
•Automatic voltage regulation (AVR) — corrects fluctuations without drawing on the battery
Automatic voltage regulation (AVR) that absorbs power fluctuations without drawing on the battery. Comfortable runtime for a full workstation, long enough to save everything before shutdown.
Automatic voltage regulation (AVR) that steadies the power without drawing on the battery. Enough runtime to save your work and shut the PC down cleanly during an outage.