Pure sine wave output for a particularly clean power supply, with a runtime of around 7.5 minutes at half load.

  • Runtime around 7.5 minutes at half load (660 W), 3.5 minutes at 75%
  • All the outlets are backed up by the battery
  • RS232 and USB ports for automatic system shutdown
  • Surge protection for the telephone/network line (RJ11/RJ45)
  • Automatic voltage regulator (AVR, 1 boost / 1 buck)
  • Pure sine wave output
  • 2U rack format, convertible to a tower
  • LCD screen
  • Emergency power off (EPO)
  • Slot for an optional SNMP network card
  • Audible noise below 50 dB
Ref.: PWUP-LI220AG-CG
4 059,00 DHincl. VAT

Configuration · nJoy Argus

Out of stock

Under Law 09-08, you have the right to access, rectify and object to the processing of your personal data. This processing has been authorised by the CNDP under no. D-CE-389/2015. Learn more

Can’t wait?

Ask for an alternative on WhatsApp

Quick reply

Manufacturer's datasheetView the PDF · 286 Ko — downloadable

Product overview

Professional rack-mount UPS for an IT cabinet: line-interactive with voltage regulation, 2200 VA / 1320 W, rack form factor.
Technology & protection: it switches to battery the instant the power cuts out, absorbs surges and corrects voltage dips and spikes without drawing on the battery.
Power: 2200 VA for 1320 W of usable output.
Outlets: 4 C13 outlets (for computer and server power cords).
Mounts directly in an IT cabinet.
LCD display: it shows the load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software.
Ideal, for example, for a server, a switch or a NAS in a rack.
Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.

See all the specifications ↓
Request a quoteShare:

Technical specifications

Technical specifications
Output voltage230 VAC
Waveform typePure sine wave
Output connections(4) IEC C13
Input voltage230 VAC
Input frequency50/60 Hz (auto detection)
Voltage range165-290 V
Automatic voltage regulation (AVR)AVR step-up and step-down (boost and buck), input range 165 - 290 V
Battery type2 internal GP09122F batteries
Battery managementCharging when the unit is off, protection against deep discharge and overcharge
Typical recharge time4 hours to 90% of capacity
Interface port1 RS-232 serial port, 1 USB HID port, 1 intelligent port for SNMP card (not supplied)
User interfaceLCD screen (load level, battery level, mains mode, battery mode, fault)
Audible alarmAudible alarm: load, battery level, mains mode, battery mode, fault
Power management softwarePowerMonitor
Weight (kg)16.5 kg
Dimensions (W x D x H) (mm)438 x 400 x 88 mm
TechnologyLine Interactive
Power (VA)2,200 VA
Voltage stabiliserYes
Technical specifications (continued)
Replacement batteryGP09122F (nJoy part number BTVACIUOCTA2FBT01B)
Communication card slot1 intelligent port for SNMP card (optional, not supplied)
Data line protection2 RJ11 / RJ45 sockets (in and out) for modem, phone and network
Rack height2U
Transfer/switching time4 ms typical
Cold startYes
Emergency power-off switchYes
Audible noise<50dB
Power factor (ratio)≥ 0.6
Output frequency50 Hz or 60Hz ± 1 Hz
Phase (output/input)Single-phase
Output typeC13 outlets
Power (W)1,320 W
Runtime17 min at 25% load; 7.5 min at 50%; 3.5 min at 75%
Form factorConvertible rack/tower
Battery-backed outlets3 to 4 outlets
Control & communicationUSB, RS232 serial port, Network (SNMP / monitoring)
Warranty3 years

Customer reviews

No reviews yet

Be the first to review this product and help other customers.

Write a review
Your rating
5/5

Shown publicly with your review.

Never published — a confirmation email will be sent to you.

Tell us about the product — in a few lines:

  • what you liked in everyday use;
  • the quality and performance you found;
  • who you would recommend it to, and why.

A question about an order, a delivery or a payment? Write to us and we will reply to you directly.

Under Law 09-08, you have the right to access, rectify and object to the processing of your personal data. This processing has been authorised by the CNDP under no. D-CE-389/2015. Learn more

Frequently asked questions about this product

How long does the Argus 2200 run on battery?
7 minutes 30 seconds at 50% load, i.e. 660 W, and 3 minutes 30 seconds at 75%. The gap is clear: on this UPS, every extra step of load costs a lot of runtime, and aiming for half the rated power is the best setting.
Does the Argus 2200 output a pure sine wave?
Yes, the output waveform in battery mode is a pure sine wave — rare on a line-interactive unit, which usually produces a stepped, reconstructed signal. The accepted input range extends from 165 to 290 V.
Are all four C13 outlets battery-backed?
Yes, all four C13 outlets are powered by the battery: none is reserved for surge protection only. RJ11/RJ45 line protection also covers the telephone and the network.
Can the Argus 2200 be installed in a rack or as a tower?
Both: a convertible 2U chassis, 400 mm deep, 438 wide and 88 high, weighing 16.5 kg. This moderate depth lets it fit into cabinets where many UPS units of the same power will not go.
Why does 2200 VA give only 1320 W?
The power factor is 0.6: 2200 × 0.6 = 1320 W actually available. Compare this wattage with the combined consumption of what you put in the rack, and keep some headroom — runtime depends directly on it.
Can the Argus 2200 be used behind a generator?
Yes, generator compatibility is stated. This is far from universal: many UPS units reject the irregular frequency of a generator and immediately switch back to battery, which drains it in a few minutes.
How do you monitor the Argus 2200 or shut it down in an emergency?
Four interfaces: USB HID, RS-232, SNMP for network monitoring via an optional card, and an EPO emergency power-off contact. An LCD screen shows the status, the load and the battery level without any software.
What does the Argus 2200's AVR correct?
A regulator with one boost step and one buck step raises low voltages and lowers high voltages without switching to battery. As long as the mains stays within the accepted range, the battery stays full for real power cuts.
Can two Argus 2200 units be combined to double the power?
No, parallel operation is not supported. For more power, you need to move up the range; the UPS itself houses two internal GP09122L batteries, with no external battery pack provided for.
Is the nJoy Argus 2200 UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document for 3 years. Its noise level stays below 50 dB, in line with installation in a rack or a server room. The datasheet details the protections.

Trending

Chat on WhatsApp

Scan with my phone

The simplest way: open your phone camera and point it at this code. The chat opens with your message ready.

Open WhatsApp Web

Works if your phone is already linked to this computer.

Prefer to call? (+212) 05 30 31 64 21