2U in a rack: it slides in without taking a server's place. 13 minutes of runtime at half load (1200 W), 31 minutes for 600 W drawn, and every outlet is battery-backed.
Height 2U in a rack
Runtime 13 minutes at half load (1200 W)
Runtime 31 minutes for 600 W drawn
Every outlet is backed up by the battery
C13 outlets: the format of computer and server power cords
Reinforced 16 A C19 outlet for power-hungry equipment
Sine wave output
Automatic and manual internal bypass
LCD status and control display
USB and RS-232 serial ports for automatic server shutdown
Online UPS for servers and network racks: online double-conversion, 3000 VA / 2400 W, rack form factor. Technology & protection: power is fully regenerated, continuously — your servers are never connected directly to the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 3000 VA for 2400 W of usable power — one or more servers. Runtime: approx. 12 minutes at half load (1200 W), 7 minutes at 70%. Outlets: 6 C13 outlets + 1 heavy-duty C19 outlet. Rack form factor for cabinet installation; active cooling (≈ 50 dB). LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Ideal, for example, for servers or business network equipment. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
What does online double-conversion technology offer compared with a conventional UPS?
The power is fully and continuously regenerated: your servers are never connected directly to the mains and there is zero transfer time during a power cut. The output remains at 230 V and 50/60 Hz (± 3 Hz).
What waveform does it deliver when it switches to battery?
A sine wave, like that of the mains, with a 3:1 crest factor. It is neither a stepped (simulated) sine wave nor a square wave: on battery as on mains power, the output remains 230 V sine wave at 50/60 Hz.
How long does it actually last during a power cut?
12 minutes at 1,200 W, i.e. half its capacity, and 7 minutes at 1,680 W. On a light 600 W load, runtime rises to 31 minutes: enough to shut down servers cleanly, not to ride out a long power cut.
How long does the battery take to recharge after a power cut?
About 4 hours for a full recharge, with 118 W of charging power and a sealed lead-acid battery. If a second power cut occurs before the cycle is complete, the available runtime is reduced accordingly.
Can it be installed in an occupied office?
It is best avoided: its noise level is 50 dBA, clearly audible in a quiet room. It belongs in a technical room or a network rack — it is a 2U rack-mount UPS, designed for the rack.
What rack cabinet is needed to house this SRV3KRI?
It occupies 2U and measures 437 × 632 × 86 mm: it is the 63.2 cm depth that you need to check before ordering, as well as the available height. Make sure the rack cabinet can support its 27.6 kg.
How do you connect a device whose plug is not a server-type plug?
The outputs are IEC outlets: 6 C13 outlets and 1 C19 outlet, all battery-backed, with the input on a C20 inlet. These are the connectors used by server and rack power cords; a device with a household plug therefore needs a cord to C13.
What is in the box, and are the rack-mounting brackets included?
Yes, the rack-mounting brackets are included. The box also contains an RS-232 cable for UPS signalling, a USB cable, the software CD and the user manual.
Can the UPS be monitored from a server or a network card?
Yes: it provides a USB port and a DB-9 RS-232 port with the software supplied, and has one available management slot. Without any PC, its multifunction LCD console already displays the status, load and remaining runtime.
What happens if work needs to be done on the UPS without shutting down the servers?
It features an internal bypass, both automatic and manual: the load can be transferred directly to the mains. An audible alarm also signals each switch to battery, and a continuous alarm signals any overload.
Can it cope with an unstable power grid with frequent voltage drops?
Yes: it accepts an input of 100 to 280 V (at half load) and 40 to 70 Hz while delivering 230 V. The voltage stabiliser is built in, and it also accepts input voltages of 220 or 240 V.
How much power does it consume on top of the equipment it protects?
Its efficiency is 88% at full load: allow for about 12% losses, the price of double conversion, which continuously regenerates the power instead of letting the mains power pass through.
What standards and certifications underpin its electrical safety?
It is CE and EAC certified, built to IEC 62040-1-1 and IEC 62040-1-2 standards, RoHS compliant and covered by a REACH declaration. Its surge protection is rated at 600 joules.
Can it operate in a technical room without air conditioning?
It is rated for 0 to 40 °C, 0 to 95% non-condensing humidity and an operating altitude of up to 3,000 m. Its IP20 rating makes it an indoor device: no protection against water splashes, so install it in a dry place.
Is the UPS new and under warranty?
Yes: new and genuine APC, part number SRV3KRI, covered with its invoice by a 2-year repair or replacement warranty. Full details are in the manufacturer datasheet (PDF).
Online double-conversion UPS rated 6000 VA for 6000 W, with no internal battery: it runs on one to four external cabinets. With one 2U cabinet of 16 HR09122F batteries, it holds 17 min at half load and 5 min at full load.
•6000 VA / 6000 W: output power factor 1.0
•Online double conversion, zero transfer time
•External batteries only: 2U or 3U cabinet, up to 4
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 7 minutes at 70% load (4200 W)
•Tower format, floor-standing
In stock
17 399 DHincl. VAT17 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
2000 VA / 1800 W, double-conversion online
•2U rack: 438 × 462 × 86 mm, 18.8 kg
•4 IEC C13 outlets, C14 inlet
In stock
11 999 DHincl. VAT11 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
A 1500 VA / 1500 W Smart-UPS SRT online UPS in 2U rack format, delivered with its NMC 3 network management card and rails. Pure sine wave output, six C13 outlets in two controllable groups, swappable battery and runtime expandable with external packs.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
Short 438 mm depth for small racks: power continuously regenerated with zero transfer time, 4 C13 outlets, hot-swappable batteries and automatic server shutdown over USB or RS232.
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
An online double-conversion 2U rack or tower UPS for a network rack: 900 W of pure sine wave power, hot-swappable batteries, runtime extendable with an external pack and rail kit included.
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•1500 VA / 1500 W, double-conversion online
•NMC 3 network card pre-installed
•6 C13 outlets in 2 controllable groups
In stock
23 399 DHincl. VAT23 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•2000 VA / 1800 W, double-conversion online
•2U rack: 438 × 462 × 86 mm, 18.8 kg
•4 IEC C13 outlets, C14 inlet
In stock
11 999 DHincl. VAT11 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.