nJoy Balder 1500 Online UPS - 1500 W / 1500 VA - 8 C13 outlets (PWUP-OL150BA-AZ)
Convertible: it stands on the floor or mounts in a 19-inch rack over 2U. Around 11 minutes of runtime at half load (750 W), and the network or telephone line is protected against surges too.
Runtime: 11 min at 50% load (750 W), 27 min at 25%, 3 min at full load
C13 outlets: the format of computer and server power cords
4 of the 8 outlets are programmable to switch off secondary equipment
Convertible: rack mounting over 2U or tower placement
Pure sine wave output
USB and RS-232 ports and an intelligent port for an optional SNMP or Modbus card
ViewPower software for monitoring and automatic shutdown
Hot-swappable batteries
Optional external battery pack to extend the runtime
2 RJ11/RJ45 ports: the network or telephone line is protected against surges
Input voltage accepted from 160 to 300 V at full load, from 110 V at half load
A rack/tower convertible online UPS: online double conversion, 1500 VA / 1500 W, 2U format. Technology & protection: power is fully and continuously regenerated — your servers never touch the mains, with no transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 1500 VA for 1500 W of real power — its power factor of 1 makes all of the rated power available in watts, where a conventional UPS loses almost half of it. Outlets: 8 C13 outlets (computer and server power cords). LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Ideal, for example, for a server, a NAS or a switch, in a rack or tower setup. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the Balder 1500 run on battery?
27 minutes at 25% load, 11 minutes at 50% (750 W), 6 minutes at 75% and 3 minutes at full load. The difference is dramatic: it is the headroom you leave that determines the runtime, far more than the stated capacity.
Does this 1500 VA unit really deliver 1500 W?
Yes: its output power factor is 1, so the full 1500 VA is available in watts. On a desktop UPS at 0.55, only 825 would remain for the same stated rating.
What are the programmable outlets on the Balder 1500 for?
Four of the eight C13 outlets can be controlled: you can set them to cut power to secondary equipment after a certain time on battery, so that the remaining runtime is kept for the server that really matters.
Can the Balder 1500 be rack-mounted or used as a tower?
Both: it is a 2U convertible chassis, measuring 88 mm high, 438 wide and 410 deep, weighing 15.5 kg. You can slide it into a 19-inch cabinet or stand it on the floor.
What input voltage does the Balder 1500 accept?
From 160 to 300 V at full load, and from as low as 110 V at half load, at a frequency of 40 to 70 Hz. This latitude lets it stay in normal mode where an ordinary UPS would switch to its batteries.
Does the Balder 1500 work with a generator?
Yes, it is rated generator-compatible: its wide voltage and frequency range absorbs the fluctuations of a standalone power source, which is not the case with every UPS.
Can the batteries of the Balder 1500 be replaced without shutting it down?
Yes, they are hot-swappable: three HR09122F modules are fitted as standard, and an external battery cabinet is available as an option to extend the runtime.
How do you monitor the Balder 1500?
Through a USB port, an RS-232 serial port and an intelligent slot that accepts an optional SNMP or Modbus card. The ViewPower software handles monitoring and automatic shutdown of the machines.
Does the Balder 1500 protect the network line?
Yes, two RJ11/RJ45 ports pass through the unit and protect the line — modem, telephone or network — against surges. On the mains side, surge absorption reaches 624 joules.
How long does it take to recharge the Balder 1500?
3 hours to recover 95% of capacity, at the default charging current of 2 A — adjustable up to 12 A to charge faster. Switching to battery, for its part, is instantaneous.
Is the Balder 1500 noisy, and does it use a lot of power?
It stays below 50 dB, and its efficiency exceeds 89% in normal operation, rising to over 95% in ECO mode. On a unit that runs day and night, this difference shows up on the bill.
Is the nJoy Balder 1500 UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document for 3 years. It delivers a pure sine wave and features emergency power off, cold start and an internal bypass. The datasheet covers the rest.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
9 199 DHincl. VAT9 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
4 599 DHincl. VAT4 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime: 6 min at 50% load (400 W), 19 min at 25%
•Schuko outlets: an everyday device plugs straight in, with no adapter
•Automatic NAS or server shutdown over USB HID, compatible with Synology NAS units
In stock
2 795 DHincl. VAT2 795,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)