Schneider Electric SRV2KRIL-IN Uninterruptible Power Supply (SRV2KRIL)
Continuously regenerated, the power reaching the servers no longer follows the ups and downs of the mains and the transfer time is zero. 2000 VA for 1600 W of usable power, in a rack chassis 172 mm high.
Online double conversion technology, with no transfer time
2000 VA for 1600 W of usable power
Rack format: 438 mm wide, 632 mm deep, 172 mm high
Input frequency accepted from 40 to 70 Hz
IP20 protection rating
Weight 49.3 kg
Ref.: SRV2KRIL
Out of stock
1/4
20 099,00 DHincl. VAT
Out of stock
Product overview
An online UPS for servers and network racks: online double conversion, 2000 VA / 1600 W, rack-mount. Technology & protection: power is fully and continuously regenerated — your servers are never connected directly to the mains, with no transfer time whatsoever. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 2000 VA for 1600 W of real power — one or more servers. Outlets: C13 outlets (computer and server power cords). Rack-mount format for direct installation in an IT rack. Ideal, for example, for servers, a switch or storage arrays. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
What does the SRV2KRIL's double conversion bring?
The power is fully and continuously regenerated: your servers are never connected directly to the mains and are spared its dips and interference. There is therefore no transfer time during a power cut.
How much power can the SRV2KRIL handle?
1600 W, for the stated 2000 VA. It is this wattage that must be compared with the combined consumption of your servers and network equipment, never the VA figure in the product name.
How much rack space does the SRV2KRIL take up?
172 mm high by 438 wide, and above all 632 mm deep: measure your cabinet before ordering. It weighs 49.3 kg and goes at the bottom of the rack.
Can the SRV2KRIL cope with an unstable power grid?
Its accepted input frequency ranges from 40 to 70 Hz, a much wider range than the nominal 50 Hz. It therefore copes with a source whose frequency drifts, where an ordinary UPS would drop onto battery.
Which outlets does the SRV2KRIL have?
C13 outputs, the format used by computer and server power cords. Plan on IEC cords for your machines: there is no household socket on this rack unit.
Is the Schneider Electric SRV2KRIL new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It carries an IP20 rating and operates between 0 and 40 °C: it is an indoor unit, to be installed in a rack or a clean technical room.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
•Usable power 2400 W
•Battery life 13.5 minutes at half load (1200 W)
•Battery life 5 minutes at full load
In stock
•Internal bypass and maintenance bypass as standard
In stock
21 199 DHincl. VAT21 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 7 minutes at 70% load (4200 W)
•Tower format, floor-standing
In stock
18 599 DHincl. VAT18 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
14 799 DHincl. VAT14 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
•Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)