Ten minutes of runtime at half load (450 W) and a colour LCD screen showing the load, the battery and the time remaining. Below 45 dB, it finds its place in an office as well as in a rack.
Runtime: 10 min at 50% load (450 W), 23 min at 25%, 3 min 38 s at full load
C13 outlets: the format of computer and server power cords
Pure sine wave output
USB HID and RS-232 ports for automatic server shutdown
SNMP port for remote monitoring through an optional card
PowerGuide and PowerMaster software for monitoring
Multifunction colour LCD screen
Optional external battery pack to extend the runtime
An online UPS to protect a server or sensitive equipment: online double conversion, 1000 VA / 900 W. Technology & protection: power is fully and continuously regenerated — your devices are never connected directly to the mains, with no transfer time whatsoever. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 1000 VA for 900 W of real power — its excellent power factor puts almost all of the rated power to work in watts. Outlets: 8 C13 outlets (computer and server power cords). LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Ideal, for example, for a small server, a NAS or a switch. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the Aster 1K run on battery?
10 minutes at half load, i.e. 450 W. The runtime depends directly on what you plug in: the lighter the load, the longer it lasts — which is why you should not aim for the unit's limit.
What voltage range does the Aster 1K accept?
From 80 to 300 V, at a frequency of 40 to 70 Hz: an exceptionally wide range. Where an ordinary UPS would switch to battery, this one keeps running on mains power.
How much load can the Aster 1K handle?
900 W, for a rated 1000 VA: its output power factor of 0.9 makes almost all of the apparent power available, whereas a desktop UPS loses nearly half of it.
Is the output waveform of the Aster 1K a pure sine wave?
Yes, a pure sine wave, with distortion below 5% even on a non-linear load and voltage held within ±1% on battery. Switching is instantaneous: double conversion never cuts out.
What happens if the Aster 1K is overloaded?
It does not shut down straight away: between 105 and 110%, it only raises an alarm; between 110 and 120%, it switches to bypass after 60 seconds; above 120%, it switches to bypass immediately.
How do you monitor the Aster 1K?
Through an HID USB port, an RS-232 serial port, an SNMP port for network monitoring and an EPO emergency power-off input. The monitoring and automatic shutdown software can be downloaded free of charge.
Can the Aster 1K stay in an office?
Yes: it stays below 45 dB, which is low for a double-conversion unit. A convertible chassis 88 mm high, 438 wide and 430 deep, weighing 13.7 kg: rack or floor-standing, as you prefer.
Does the Aster 1K work with a generator?
Yes, it is rated generator-compatible: its input range of 80 to 300 V and 40 to 70 Hz absorbs the fluctuations of a standalone power source, which not every UPS can handle.
Can the batteries of the Aster 1K be replaced?
Yes, the unit is designed for easy replacement of its three GP07122L modules, and an external battery pack is available as an option to extend the runtime.
Is the nJoy Aster 1K UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document for 3 years. Its colour LCD screen shows load, battery, voltages and remaining time; efficiency reaches 97% in ECO mode. The datasheet covers the rest.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Runtime: 6 min at 50% load (400 W), 19 min at 25%
•Schuko outlets: an everyday device plugs straight in, with no adapter
•Automatic NAS or server shutdown over USB HID, compatible with Synology NAS units
In stock
2 795 DHincl. VAT2 795,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
8 799 DHincl. VAT8 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
9 199 DHincl. VAT9 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.