Online double conversion with PFC (power factor correction)
Waveform type
Sine wave
Output connections
Terminal block
Input voltage
200/208/220/230/240/250V
Input frequency
50 - 60 Hz (auto-selecting)
Input connections
Terminal block
Voltage range
176 - 276V
Battery type
Battery management: ABM® or temperature-compensated charging method (user-selectable), automatic battery test, deep discharge protection, external battery pack detection.
Interface port
1 USB port, 1 RS232 port (the USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 remote On/Off control mini terminal block and 1 emergency power off
User interface
Multilingual graphic LCD screen
Weight (kg)
86
Technical specifications (continued)
Dimensions (W x D x H) (mm)
440 x 260 x 700
Technology
On-line
Power (VA)
8,001 and above
Voltage stabiliser
No
Box contents
9SX power module
9SX battery module
USB cable
Serial cable
1 battery cable with communications for automatic battery cabinet recognition
2 brackets for tower mounting
Tower mounting link plate
Safety guide
Quick start
Be the first to review this product and help other customers.
Write a review
Frequently asked questions
What are the delivery times and fees?
Delivery all over Morocco within 1 to 5 working days, at the same rate in every city for parcels up to 30 kg — and free delivery from 3 000 dh of purchases. Above 30 kg, the rate follows the weight and is shown on the product page and in the basket. You are notified by SMS, then called by the courier.
Is the product new and under warranty?
Yes: a new, genuine product, delivered in its original packaging with an invoice. The invoice serves as the warranty document (2 years) with the manufacturer's after-sales service in Morocco.
Can I collect my order in store?
Yes, at the Casablanca store (Mon–Fri 10am–7pm · Sat 10am–2pm) or the Témara collection point (Mon–Fri 8.30am–1pm / 2–6pm · Sat 8.30am–12.30pm). Payment on site: cash, bank card via terminal, certified cheque.
Which payment methods do you accept?
Bank card online (secure Attijari Payment), cash on delivery, bank transfer and certified cheque. All our prices are in dirhams, VAT included.
Can I get an invoice in my company's name (with its ICE)?
Yes. Provide your company's legal name and ICE when ordering: the invoice is issued in its name and enclosed with the parcel (handed over with the order for in-store collection). Companies and public bodies can also request a quote — reply within 24 working hours.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Fifteen minutes of runtime at full load, internal batteries included. Dust filter and conformal-coated boards: it is made for demanding premises, on a three-phase 400 V input tolerated from 304 to 477 V.
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
•Runtime 11 minutes at half load (3000 W)
In stock
51 199 DHincl. VAT51 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal batteries included: 2 strings of 7 Ah, expandable to 3 for more runtime
•Three-phase 400 V input and output, also 380 or 415 V
In stock
92 399 DHincl. VAT92 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Fifteen minutes of runtime at full load, internal batteries included. Dust filter and conformal-coated boards: it is made for demanding premises, on a three-phase 400 V input tolerated from 304 to 477 V.
Network management card already fitted, with environmental monitoring: it is administered and raises alerts remotely. 9 minutes of runtime at 50% load (10 kW), extendable with battery packs.
•Runtime: 9 min at 50% load (10 kW), 5 min at 70% (14 kW)
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.