Eaton 9PX 1000 VA Online UPS - RT2U (9PX1000IRT2U)
Twenty-eight minutes of runtime at half load (500 W), and up to four hot-swappable battery modules to last several hours. Under 35 dB in operation, so bearable in an office.
Runtime of 28 minutes at half load (500 W)
1000 W genuinely available, power factor of 1
Up to 4 additional battery modules, hot-swappable
8 C13 outlets, the format used by computer and server power cords
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP, Modbus or dry contact network card
2 controllable outlet groups: secondary equipment shuts down first
Internal bypass: power still flows if the UPS fails
ABM charge management, which extends battery service life
Pure sine wave output
Multilingual graphic LCD display
Convertible: 2U rack or tower mounting, brackets included
A high-end online UPS, convertible between rack and tower: online double conversion, 1000 VA / 1000 W, 2U format. Technology & protection: power is fully and continuously regenerated — your servers are never exposed to the mains, with zero transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 1000 VA for 1000 W of real power — its power factor of 1 makes all of the rated power available in watts, where a conventional UPS loses almost half of it. Runtime: about 28 minutes at half load (500 W) — outstanding runtime, extendable with additional battery modules. Outlets: 8 C13-type outlets (the standard computer and server power cord). Management: USB and RS-232 serial ports for automatic shutdown; slot for an SNMP network card. Graphical LCD display. Quiet operation (under 35 dB). Ideal, for example, for a server, a NAS or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
176 - 276 V without derating (up to 100 - 276 V with derating)
Battery replacement
User-replaceable, hot-swappable (no power interruption)
Battery management
ABM® or temperature-compensated charging method (user-selectable), automatic battery test, deep discharge protection, automatic recognition of external batteries
Interface port
1 USB port, 1 RS232 serial port, 1 remote ON/OFF mini terminal block, 1 remote power-off mini terminal block, 1 output relay mini terminal block
User interface
Multilingual graphic LCD display
Audible alarm
Yes
Power management software
Eaton Intelligent Power
Weight (kg)
17.4 kg
Dimensions (W x D x H) (mm)
440 x 450 x 86.5 mm
Technology
On-line
Power (VA)
1,000 VA
Voltage stabiliser
Yes
Box contents
9PX uninterruptible power supply
2 IEC output power cords
USB cable
Serial cable
2 brackets for 19-inch mounting
2 universal rails
2 brackets for tower mounting
Cable locking systems
Safety guide
Quick start
Technical specifications (continued)
Communication card slot
1 slot for Network-MS, ModBus-MS or Relay-MS card (optional)
Rack height
2U
Transfer/switching time
0 ms (continuous double conversion)
Bypass
Internal bypass
Audible noise
< 35 dBA
Power factor (ratio)
1
Input power factor
Input power factor correction (PFC), ratio not published by the manufacturer
Output frequency
50 - 60 Hz
Phase (output/input)
Single-phase / Single-phase
Eco mode efficiency
97.5% in high-efficiency mode
Double-conversion efficiency
Up to 91.5% in online mode
Output type
C13 outlets
Power (W)
1,000 W
Runtime
28 min at 300 W; 16 min at 500 W; 9 min at 800 W
External battery packs
Up to 4 hot-swappable external battery modules (EBM 9PXEBM48RT2U)
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the 9PX 1000 RT2U run on battery?
28 minutes at half load, i.e. 500 W. That is exceptionally long for this power rating, and runtime can reach several hours with up to four hot-swappable battery modules.
Does this 1000 VA UPS really deliver 1000 W?
Yes: the power factor is 1, so all of the apparent power is available in watts. On a conventional UPS with a 0.7 power factor, only 700 would remain.
What does ABM charge management bring on the 9PX 1000?
It only recharges the batteries when necessary, instead of keeping them on permanent charge: this prevents plate corrosion and extends their service life.
What are the controllable outlet groups for?
To switch off secondary equipment first during an outage: two groups can be controlled separately, which reserves the whole battery for critical machines. That is extra runtime with no additional hardware.
What outlets does the 9PX 1000 RT2U have?
Eight C13 outlets on the output, with a C14 input. Two IEC output cords are supplied, along with the rack and tower mounting brackets and a cable locking system.
Can a 1000 VA online UPS stay in an office?
This one, yes: it is rated at less than 35 dBA, remarkably low for a double-conversion unit. Allow for 17.4 kg for a 2U chassis 440 mm wide and 450 mm deep.
Does power still get through if the UPS breaks down?
Yes, an internal bypass lets mains power through to the equipment. The unit also accepts an input of 176 to 276 V before drawing on its battery.
Is the Eaton 9PX 1000 RT2U (9PX1000IRT2U) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It delivers a pure sine wave output, shows its status on a multilingual graphic LCD screen and has a slot for a Network-MS, ModBus-MS or Relay-MS card. The datasheet covers the rest.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
•Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
Online double-conversion UPS rated 6000 VA for 6000 W, with no internal battery: it runs on one to four external cabinets. With one 2U cabinet of 16 HR09122F batteries, it holds 17 min at half load and 5 min at full load.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
2000 VA / 1800 W, double-conversion online
•2U rack: 438 × 462 × 86 mm, 18.8 kg
•4 IEC C13 outlets, C14 inlet
In stock
11 999 DHincl. VAT11 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
An online double-conversion 2U rack or tower UPS for a network rack: 900 W of pure sine wave power, hot-swappable batteries, runtime extendable with an external pack and rail kit included.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Short 438 mm depth for small racks: power continuously regenerated with zero transfer time, 4 C13 outlets, hot-swappable batteries and automatic server shutdown over USB or RS232.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
10 399 DHincl. VAT10 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A