Eaton 9PX 1000 VA Online UPS - RT2U (9PX1000IRT2U)
Twenty-eight minutes of runtime at half load (500 W), and up to four hot-swappable battery modules to last several hours. Under 35 dB in operation, so bearable in an office.
Runtime of 28 minutes at half load (500 W)
1000 W genuinely available, power factor of 1
Up to 4 additional battery modules, hot-swappable
8 C13 outlets, the format used by computer and server power cords
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP, Modbus or dry contact network card
2 controllable outlet groups: secondary equipment shuts down first
Internal bypass: power still flows if the UPS fails
ABM charge management, which extends battery service life
Pure sine wave output
Multilingual graphic LCD display
Convertible: 2U rack or tower mounting, brackets included
A high-end online UPS, convertible between rack and tower: online double conversion, 1000 VA / 1000 W, 2U format. Technology & protection: power is fully and continuously regenerated — your servers are never exposed to the mains, with zero transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 1000 VA for 1000 W of real power — its power factor of 1 makes all of the rated power available in watts, where a conventional UPS loses almost half of it. Runtime: about 28 minutes at half load (500 W) — outstanding runtime, extendable with additional battery modules. Outlets: 8 C13-type outlets (the standard computer and server power cord). Management: USB and RS-232 serial ports for automatic shutdown; slot for an SNMP network card. Graphical LCD display. Quiet operation (under 35 dB). Ideal, for example, for a server, a NAS or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
176 - 276 V without derating (up to 100 - 276 V with derating)
Battery replacement
User-replaceable, hot-swappable (no power interruption)
Battery management
ABM® or temperature-compensated charging method (user-selectable), automatic battery test, deep discharge protection, automatic recognition of external batteries
Interface port
1 USB port, 1 RS232 serial port, 1 remote ON/OFF mini terminal block, 1 remote power-off mini terminal block, 1 output relay mini terminal block
User interface
Multilingual graphic LCD display
Audible alarm
Yes
Power management software
Eaton Intelligent Power
Weight (kg)
17.4 kg
Dimensions (W x D x H) (mm)
440 x 450 x 86.5 mm
Technology
On-line
Power (VA)
1,000 VA
Voltage stabiliser
Yes
Box contents
9PX uninterruptible power supply
2 IEC output power cords
USB cable
Serial cable
2 brackets for 19-inch mounting
2 universal rails
2 brackets for tower mounting
Cable locking systems
Safety guide
Quick start
Technical specifications (continued)
Communication card slot
1 slot for Network-MS, ModBus-MS or Relay-MS card (optional)
Rack height
2U
Transfer/switching time
0 ms (continuous double conversion)
Bypass
Internal bypass
Audible noise
< 35 dBA
Power factor (ratio)
1
Input power factor
Input power factor correction (PFC), ratio not published by the manufacturer
Output frequency
50 - 60 Hz
Phase (output/input)
Single-phase / Single-phase
Eco mode efficiency
97.5% in high-efficiency mode
Double-conversion efficiency
Up to 91.5% in online mode
Output type
C13 outlets
Power (W)
1,000 W
Runtime
28 min at 300 W; 16 min at 500 W; 9 min at 800 W
External battery packs
Up to 4 hot-swappable external battery modules (EBM 9PXEBM48RT2U)
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the 9PX 1000 RT2U run on battery?
28 minutes at half load, i.e. 500 W. That is exceptionally long for this power rating, and runtime can reach several hours with up to four hot-swappable battery modules.
Does this 1000 VA UPS really deliver 1000 W?
Yes: the power factor is 1, so all of the apparent power is available in watts. On a conventional UPS with a 0.7 power factor, only 700 would remain.
What does ABM charge management bring on the 9PX 1000?
It only recharges the batteries when necessary, instead of keeping them on permanent charge: this prevents plate corrosion and extends their service life.
What are the controllable outlet groups for?
To switch off secondary equipment first during an outage: two groups can be controlled separately, which reserves the whole battery for critical machines. That is extra runtime with no additional hardware.
What outlets does the 9PX 1000 RT2U have?
Eight C13 outlets on the output, with a C14 input. Two IEC output cords are supplied, along with the rack and tower mounting brackets and a cable locking system.
Can a 1000 VA online UPS stay in an office?
This one, yes: it is rated at less than 35 dBA, remarkably low for a double-conversion unit. Allow for 17.4 kg for a 2U chassis 440 mm wide and 450 mm deep.
Does power still get through if the UPS breaks down?
Yes, an internal bypass lets mains power through to the equipment. The unit also accepts an input of 176 to 276 V before drawing on its battery.
Is the Eaton 9PX 1000 RT2U (9PX1000IRT2U) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It delivers a pure sine wave output, shows its status on a multilingual graphic LCD screen and has a slot for a Network-MS, ModBus-MS or Relay-MS card. The datasheet covers the rest.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.