APC Smart-UPS SRT SRT2200RMXLI Online UPS - 1980 W / 2200 VA - 8 C13 outlets + 2 C19 outlets
Allow eleven minutes at half load (990 W) and seven minutes at 70% to shut the servers down cleanly. A rack chassis of just 2U, LCD display, built-in bypass and additional battery modules to extend the runtime.
Runtime of 11 minutes at 50% load (990 W) and 7 minutes at 70% (1386 W)
C13 outlets: the format used by computer and server power cords
C19 outlets: heavy-duty 16 A outlets for power-hungry equipment
Pure sine wave output
LCD display: load, battery level and remaining runtime at a glance
Free slot for a network management card
Built-in bypass: power still flows if the UPS fails
Runtime extendable with additional SRT72RMBP battery modules
Replaceable battery, reference APCRBC141
Full recharge in 3 hours
Emergency power off switch
2U rack format, rails and mounting brackets included
55 dBA noise level: active ventilation, to be installed in a technical room
An online UPS for servers and network racks: online double conversion, 2200 VA / 1980 W, rack format. Technology & protection: power is fully and continuously regenerated — your servers are never connected directly to the mains, with zero transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 2200 VA for 1980 W of real power (0.9 power factor) — almost all of the rated power is available in watts, for one or more servers. Runtime: extendable with an additional battery module for longer backup. Outlets: 8 C13 outlets + 2 heavy-duty C19 outlets for power-hungry equipment. 2U rack chassis; like every online model, it has active cooling — to be installed in a rack or technical room. LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Ideal, for example, for business servers, storage or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the SRT2200RMXLI run on battery?
11 minutes at 50% load, i.e. 990 W, and 7 minutes at 70%, i.e. 1386 W. A full recharge takes 3 hours, and the runtime can be extended with SRT72RMBP modules.
Does the SRT2200RMXLI plug into a wall socket?
Yes: the input accepts a C20, Schuko or British connection. No hardwiring or electrician needed, unlike higher-power UPSs connected via a terminal block.
Which outlets does the SRT2200RMXLI have?
Eight C13 outlets, two heavy-duty 16 A C19 outlets and two IEC jumpers. C19 is the format for high-current equipment: blade chassis, storage arrays.
How much rack space does the SRT2200RMXLI take up?
Just 2U, for 25 kg, with the rails and mounting brackets supplied. That is compact for a 2200 VA online UPS — most competitors require 3U or more.
Why does 2200 VA only give 1980 W?
The power factor is 0.9: 1980 W actually available. That is almost all of the apparent power — compare this figure in watts with the combined consumption of your servers.
Does power still get through if the UPS fails?
Yes, a built-in bypass lets mains power through to the equipment. Conversely, an emergency power off switch lets you cut everything instantly.
Is the SRT2200RMXLI's battery replaceable?
Yes, under the reference APCRBC141. A free slot also lets you add a network management card, in addition to the USB port.
Is the APC Smart-UPS SRT SRT2200RMXLI new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for a period of 3 years. It delivers a pure sine wave, accepts an input of 40 to 70 Hz and runs at 55 dBA: to be installed in a technical room. The datasheet covers the rest.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
•
•
Runtime 7 minutes at 70% load (4200 W)
•Height 4U in a rack
In stock
27 299 DHincl. VAT27 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Built-in network card to monitor and control the UPS remotely
•1980 W genuinely available
•8 C13 outlets, the format of computer and server power cords
In stock
27 099 DHincl. VAT27 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 5 minutes at 70% load (7000 W)
•3-wire terminal block connection: fixed wiring, to be installed by an electrician
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords