Twelve minutes of runtime at half load (1200 W) and seven minutes at 70%, with every outlet battery-backed. Tower format, 50 dBA in operation, and the connection cords are included.
Runtime of 12 minutes at 50% load (1200 W) and 7 minutes at 70% (1680 W)
All output outlets are battery-backed
C13 outlets: the format used by computer and server power cords
C19 outlet: heavy-duty 16 A outlet for power-hungry equipment
Pure sine wave output
LCD display: load, battery level and remaining runtime at a glance
USB cable and RS-232 cable included for automatic server shutdown
Free slot for a network management card
Automatic and manual internal bypass
Connection cords included: input on a standard socket and a C13 to C14 cord
Accepted input voltage from 160 to 280 V at full load
Online UPS to protect servers and sensitive equipment: online double-conversion, 3000 VA / 2400 W. Technology & protection: power is continuously rebuilt — the servers never touch the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 3000 VA for 2400 W of usable power — one or more servers. Runtime: approx. 12 minutes at half load (1200 W), 7 minutes at 70%. Outlets: 6 C13 outlets + 1 heavy-duty C19 outlet for power-hungry equipment. Like every online model, it uses active cooling: best installed in a technical room. LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Ideal, for example, for servers, storage or business network equipment. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
160 - 280 V at full load; 110 - 285 V at half load
Battery type
Sealed maintenance-free lead-acid battery with suspended electrolyte: leakproof, 72 V bus
Typical recharge time
4 hours
Interface port
1 USB port, 1 RS-232 serial port
User interface
Multifunction LCD status and control console
Audible alarm
Alarm when switching to battery mode; distinct low-battery alarm; continuous alarm on overload
Weight (kg)
26.8 kg (29 kg with packaging)
Dimensions (W x D x H) (mm)
190 x 425 x 336 mm
Estimated battery service life (years)
3 to 5 years
Technology
On-line
Power (VA)
3,000 VA
Technical specifications (continued)
Voltage stabiliser
Yes
Box contents
IEC C19 to Schuko power cord · IEC C13 to C14 power cord · USB cable · RS-232 configuration cable · UPS signalling RS-232 cable · Software CD · User manual
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the SRV3KI last on battery?
12 minutes at 50% load, i.e. 1200 W, and 7 minutes at 70%, i.e. 1680 W. A full recharge then takes 4 hours: after a long outage, the UPS needs half a day to get its full reserve back.
Does the SRV3KI plug into an ordinary wall socket?
Yes: two cords are supplied, a C19 to Schuko and a C13 to C14. So you need neither to call in an electrician nor to order a cord to connect the UPS and a first machine.
Are all of the SRV3KI's outlets on battery backup?
Yes: the six C13 outlets and the heavy-duty C19 outlet are all on battery backup. None is limited to surge protection alone, which leaves you completely free in how you distribute your machines.
What input voltage does the SRV3KI accept?
160 to 280 V at full load, and a window widened to 110-285 V at half load: the tolerance depends on the load. The accepted frequency is 40 to 70 Hz.
What is the quality of the power delivered by the SRV3KI?
A sine wave with a crest factor of 3:1, continuously rebuilt by double conversion and synchronised with the grid at 50/60 Hz ± 3 Hz. Output quality therefore does not depend on the quality of the incoming grid.
Can you work on the UPS without shutting down the servers?
Yes, an automatic and manual internal bypass keeps the power on: the automatic one in the event of a fault, the manual one for planned work on the unit.
How much space does the SRV3KI take up, and how much does it weigh?
19 cm wide, 42.5 cm deep and 33.6 cm high, at 26.8 kg. It is a narrow but heavy tower unit, to be placed on the floor: it is not a device you install on a shelf.
Why does 3000 VA give only 2400 W?
The power factor is 0.8: 3000 × 0.8 = 2400 W actually available. That is well above the 0.6 of entry-level UPSs, but it is this figure in watts that you need to compare with the combined consumption of your servers.
What efficiency, and does it need to go in a technical room?
88% at full load — the price of double conversion, which continuously rebuilds the power — and a noise level of 50 dBA. At that level, it is better suited to a technical room than to an office occupied all day.
How do you cleanly shut down the servers powered by the SRV3KI?
Through the USB port or the RS-232 serial port, with the software CD and USB cable supplied. A free slot also lets you add a network management card to control the UPS remotely.
Is the APC Easy UPS SRV3KI new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 2 years, covering repair or replacement. It is CE, UKCA, EAC and TISI certified; the datasheet lists all the values.
Online double-conversion UPS rated 6000 VA for 6000 W, with no internal battery: it runs on one to four external cabinets. With one 2U cabinet of 16 HR09122F batteries, it holds 17 min at half load and 5 min at full load.
•6000 VA / 6000 W: output power factor 1.0
•Online double conversion, zero transfer time
•External batteries only: 2U or 3U cabinet, up to 4
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 7 minutes at 70% load (4200 W)
•Tower format, floor-standing
In stock
17 399 DHincl. VAT17 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
2000 VA / 1800 W, double-conversion online
•2U rack: 438 × 462 × 86 mm, 18.8 kg
•4 IEC C13 outlets, C14 inlet
In stock
11 999 DHincl. VAT11 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
A 1500 VA / 1500 W Smart-UPS SRT online UPS in 2U rack format, delivered with its NMC 3 network management card and rails. Pure sine wave output, six C13 outlets in two controllable groups, swappable battery and runtime expandable with external packs.
An online double-conversion tower UPS for a server or a small rack: 1800 W of pure sine wave power, no transfer time, 13 minutes at half load and an input tolerated from 80 to 280 V.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•2000 VA / 1800 W, online double conversion
•Pure sine wave, zero transfer time
•Runtime: 13 min at half load, 4.5 min at full load
In stock
8 599 DHincl. VAT8 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
5 399 DHincl. VAT5 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed