APC Easy UPS SRV2KIL Online UPS - 1600 W / 2 kVA - 4 AC outlet(s)
49 minutes of runtime at half load (800 W) and 33 minutes at 70%: enough to ride out a whole power cut, not just to shut down in time. Outlets in the format of computer and server cords.
Runtime 49 minutes at half load (800 W)
Runtime 33 minutes at 70% load (1120 W)
C13 outlets, the format of computer and server cords
USB and RS-232 serial ports for automatic server shutdown
Full battery recharge in 5.5 hours
Battery service life of 3 to 5 years
Noise level 50 dB: best installed in a technical room
Weight 45.4 kg
Ref.: SRV2KIL
Out of stock
1/7
16 099,00 DHincl. VAT
Out of stock
Product overview
An extended-runtime online UPS for servers: online double conversion, 2000 VA / 1600 W. Technology & protection: power is continuously rebuilt — your servers are never connected directly to the mains, with no transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 2000 VA for 1600 W of real power. Runtime: about 49 minutes at half load (800 W), 33 minutes at 70% — a very long runtime, ideal where outages drag on. Outlets: 4 C13 outlets (computer and server power cords). Active cooling (≈ 50 dB), best installed in a technical room. Ideal, for example, for servers or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the SRV2KIL run on battery?
49 minutes at half load, i.e. 800 W, and 33 minutes at 70%, i.e. 1120 W. That is substantial runtime, not just a brief reprieve: it lets you ride out an entire outage rather than shut down in a hurry.
What does the SRV2KIL's double conversion bring?
The power is continuously regenerated: your servers are never connected directly to the mains and are spared its dips and interference. There is no transfer time when a power cut occurs.
How much power can the SRV2KIL handle?
1600 W, for the stated 2 kVA. It is this wattage that must be compared with the combined consumption of your servers, never the VA figure in the product name — and the more headroom you leave, the longer the runtime.
Which outlets does the SRV2KIL have?
Four C13 outputs, the format used by computer and server power cords, at 230 V. Plan on IEC cords for your machines: there is no household socket.
Can the SRV2KIL shut down the servers on its own?
Yes, it has a USB port and an RS-232 serial port: connected to your machines, they trigger a clean shutdown when the battery nears depletion. Two options, then, including for older hardware.
Can the SRV2KIL cope with an unstable power grid?
Its accepted input frequency ranges from 40 to 70 Hz, with auto-sensing, well beyond the nominal 50 Hz. At the output, it is held at 50 or 60 Hz to within ±3 Hz, synchronised with the grid.
Where should the SRV2KIL be installed?
Preferably in a technical room: it is rated at 50 dBA and dissipates 745 BTU/h, with active cooling. It is a tower 33.5 cm wide, 42.5 deep and 33.6 high, to be placed on the floor.
How much does the SRV2KIL weigh, and how long does it take to recharge?
45.4 kg — it takes two people to handle — and 5 hours 30 minutes for a full recharge. The sealed lead-acid batteries are rated for 3 to 5 years of service.
Is the APC Easy UPS SRV2KIL new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for a period of 2 years. It operates between 0 and 40 °C, at altitudes of up to 3,000 m, and carries CE, UKCA, EAC and TISI certifications.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
•Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
In stock
14 799 DHincl. VAT14 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
•Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.