Fixed terminal block wiring on the input as on the output, to be installed by an electrician: 7,200 W usable and around 15 minutes of runtime at 50% load, 10 minutes at 70%.
Usable power of 7,200 W (0.9 power factor)
Runtime of around 15 minutes at 50% load, 10 minutes at 70%
Terminal block input and output: fixed wiring, to be installed by an electrician
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP network card, remote monitoring
Intelligent Power software included, compatible with VMware and Hyper-V
Built-in bypass: power still flows even if the UPS develops a fault
Hot-swappable batteries from the front panel
Runtime extendable with external battery cabinets, detected automatically
Multilingual graphic LCD display, rotatable for rack or tower
A high-end, high-power online UPS for server rooms: online double conversion, 8000 VA / 7200 W. Technology & protection: power is fully and continuously regenerated — the equipment is never exposed to the mains, with zero transfer time. Maximum protection against outages, surges, voltage fluctuations and electrical noise. Power: 8000 VA for 7200 W of real power (0.9 power factor) — almost all of the rated power is available in watts. Ports: terminal block connection (hard-wired by an electrician); USB and serial links for management. Pure sine wave output; active cooling, to be installed in a technical room. Designed, for example, for server racks or critical infrastructure. LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the 9SX 8000i last on battery?
15 minutes at 50% load and 10 minutes at 70%, figures given at a 0.7 power factor. Runtime can be extended from a few minutes to several hours by adding external battery modules.
How many battery modules can be added to the 9SX 8000i?
Up to twelve, hot-pluggable and automatically detected by the UPS. This is what makes it possible to go from a few minutes of runtime to several hours without changing units.
How does the 9SX 8000i connect to the electrical installation?
Via a terminal block on both input and output: there are no sockets on the unit. It is fixed wiring, to be done by an electrician, with a dedicated circuit sized for 8 kVA.
Does this 8 kVA unit deliver 7200 W of usable power?
Yes, thanks to a 0.9 power factor: 8000 × 0.9 = 7200 W. The 9SX also has built-in input power factor correction, which limits the harmonics sent back onto the upstream grid.
What efficiency does the 9SX 8000i reach?
Up to 95%, and 98% in high-efficiency mode. On a unit of this power running around the clock, every point of efficiency translates directly into fewer watts of heat in the room.
What are the 9SX 8000i's load segments for?
To reserve battery runtime for critical equipment by switching off the rest. The same control also lets you remotely restart equipment that has frozen, or carry out scheduled shutdowns and restarts.
What space and weight should you allow for the 9SX 8000i?
440 × 260 × 700 mm and 84 kg, in a convertible rack or tower chassis. The model comprises a power module and a battery module: arrange for handling and a floor that can bear this load.
How do you monitor the 9SX 8000i and shut down virtualised servers?
Through a USB port or an RS-232 port — not simultaneously —, four dry contacts on DB9, a remote control mini terminal block and an emergency power-off. The Intelligent Power software, supplied, covers VMware and Hyper-V.
Is the Eaton 9SX 8000i (9SX8KIRT) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 2 years. It delivers a sine wave, stays below 48 dBA and has a built-in bypass as well as batteries that are hot-swappable from the front panel. The datasheet covers the rest.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
Fifteen minutes of runtime at full load, internal batteries included. Dust filter and conformal-coated boards: it is made for demanding premises, on a three-phase 400 V input tolerated from 304 to 477 V.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
•Runtime 11 minutes at half load (3000 W)
In stock
51 199 DHincl. VAT51 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.