The internal bypass takes over if the UPS develops a fault, and the batteries are changed hot without cutting power to the servers. 10 kW usable, around 9 minutes of runtime at 50% load.
Usable power of 10 kW (0.9 power factor)
Runtime of around 9 minutes at 50% load, 5 minutes at 70%
Terminal block input and output: fixed wiring, to be installed by an electrician
Built-in bypass: power still flows even if the UPS develops a fault
Hot-swappable batteries from the front panel
Runtime extendable with external battery cabinets, detected automatically
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP network card, remote monitoring
Intelligent Power software included, compatible with VMware and Hyper-V
Multilingual graphic LCD display, rotatable for rack or tower
A high-end, high-power online UPS for server rooms: online double conversion, 11 kVA / 10 kW, 6U rack format. Technology & protection: power is fully and continuously regenerated — the equipment is never exposed to the mains, with zero transfer time. Maximum protection against outages, surges, voltage fluctuations and electrical noise. Power: 11 kVA for 10 kW of real power (0.9 power factor) — almost all of the rated power is available in watts. Runtime can be extended with external battery cabinets. Ports: terminal block connection (hard-wired by an electrician); USB and serial ports and slot for an SNMP network card. Pure sine wave output; active cooling (≈ 50 dB), to be installed in a rack or technical room. LCD display: shows load, battery level and remaining runtime — so you can monitor the UPS without any software. Designed, for example, for server racks, network equipment or industrial applications. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the 9SX 11000i run on battery?
About 9 minutes at 50% load and 5 minutes at 70%. Runtime can be extended with external battery cabinets, which the UPS detects automatically as soon as they are connected.
How is the 9SX 11000i connected to the electrical installation?
Via a terminal block on both input and output: the unit has no outlets at all. It is fixed wiring, to be done by an electrician, with a dedicated circuit sized for 11 kVA.
Does this 11 kVA UPS deliver 10 kW of usable power?
Yes, thanks to a power factor of 0.9: 11,000 × 0.9 = 10,000 W. It is this wattage figure that you need to compare with the combined consumption of your server racks.
Does power still get through if the UPS fails?
Yes, a built-in bypass lets mains power through to the equipment. The batteries can also be hot-swapped from the front panel, without interrupting the servers.
What efficiency does the 9SX 11000i achieve?
Up to 95%, and 98% in high-efficiency mode. At this power level, every percentage point gained translates directly into fewer watts of heat in the technical room.
How do you cleanly shut down virtualised servers with the 9SX 11000i?
The Intelligent Power software is included and supports VMware and Hyper-V. It communicates via the USB port or the RS-232 port — which cannot be used simultaneously —, complemented by four dry contacts and a remote on/off control.
Is the network management card included?
No: it is only supplied as standard on the Netpack versions. On this model, the slot is free and accepts a Network-MS (SNMP), ModBus-MS or Relay-MS card, to be ordered separately.
Can the 9SX 11000i be installed in a rack or as a tower?
Both: it has a convertible chassis, with a multilingual graphic LCD screen that can be rotated to suit the chosen position. Allow for 86 kg: it takes several people to handle, and the unit goes at the bottom of the cabinet.
Is the Eaton 9SX 11000i (9SX11KIRT) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 2 years. It delivers a sine wave, accepts an input frequency of 40 to 70 Hz and stays below 50 dBA. The datasheet covers the rest.
A 15 kVA / 15 kW double-conversion online three-phase UPS with internal batteries, for a technical room or a small server room. It lasts 33 minutes at half load, accepts an additional battery module and can be paralleled up to four units.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Three-phase online UPS rated 20 kVA for 20 kW, configurable as 3:3, 3:1 or 1:1. Supplied without batteries: 32 to 40 12 V blocks inside, or external cabinets. Up to 98.5% efficiency in ECO mode, maintenance bypass and touch screen.
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
•Usable power 10,000 W
•Runtime 7 minutes at half load (5000 W)
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•20 kVA / 20 kW: output power factor 1.0
•Three-phase or single-phase: 3:3, 3:1 or 1:1 configurations
•Online double conversion, zero transfer time
In stock
52 200 DHincl. VAT52 200,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
47 999 DHincl. VAT47 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Three-phase online UPS rated 20 kVA for 20 kW, configurable as 3:3, 3:1 or 1:1. Supplied without batteries: 32 to 40 12 V blocks inside, or external cabinets. Up to 98.5% efficiency in ECO mode, maintenance bypass and touch screen.
Online double-conversion UPS rated 6000 VA for 6000 W, with no internal battery: it runs on one to four external cabinets. With one 2U cabinet of 16 HR09122F batteries, it holds 17 min at half load and 5 min at full load.
Network management card already fitted, with environmental monitoring: it is administered and raises alerts remotely. 9 minutes of runtime at 50% load (10 kW), extendable with battery packs.
•Runtime: 9 min at 50% load (10 kW), 5 min at 70% (14 kW)
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.