Up to 95 % efficiency in double conversion and 98 % in high-efficiency mode, for 7,200 W of usable power. Hot-swappable batteries and an internal bypass: maintenance does not cut power to the connected equipment.
Usable power of 7,200 W (0.9 power factor)
Battery life of around 15 minutes at 50 % load, 10 minutes at 70 %
Input and output on a terminal block: fixed wiring, to be installed by an electrician
Efficiency up to 95 %, 98 % in high-efficiency mode
Internal bypass: power still flows even if the UPS fails
Hot-swappable batteries accessible from the front panel
Runtime extendable with external battery packs, detected automatically
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP network card, remote monitoring
Multilingual graphic LCD display
Input voltage regulation, useful on an unstable mains supply
1 USB port, 1 RS232 port (the USB and RS232 ports cannot be used simultaneously), 4 dry contacts (DB9), 1 remote On/Off control mini terminal block and 1 emergency power off, 1 slot for a Network-MS network card (included in Netpack versions), ModBus-MS card or Relay-MS dry contact card
User interface
Multilingual graphic LCD screen
Audible alarm
Yes
Weight (kg)
84
Dimensions (W x D x H) (mm)
440 x 260 x 700
Technical specifications (continued)
Technology
On-line
Power (VA)
4,001 - 8,000
Voltage stabiliser
Yes
Box contents
9SX power module
9SX battery module
USB cable
Serial cable
1 battery cable with communications for automatic battery cabinet recognition
2 brackets for tower mounting
Tower mounting link plate
Safety guide
Quick start
Be the first to review this product and help other customers.
Write a review
Frequently asked questions
What are the delivery times and fees?
Delivery all over Morocco within 1 to 5 working days, at the same rate in every city for parcels up to 30 kg — and free delivery from 3 000 dh of purchases. Above 30 kg, the rate follows the weight and is shown on the product page and in the basket. You are notified by SMS, then called by the courier.
Is the product new and under warranty?
Yes: a new, genuine product, delivered in its original packaging with an invoice. The invoice serves as the warranty document (2 years) with the manufacturer's after-sales service in Morocco.
Can I collect my order in store?
Yes, at the Casablanca store (Mon–Fri 10am–7pm · Sat 10am–2pm) or the Témara collection point (Mon–Fri 8.30am–1pm / 2–6pm · Sat 8.30am–12.30pm). Payment on site: cash, bank card via terminal, certified cheque.
Which payment methods do you accept?
Bank card online (secure Attijari Payment), cash on delivery, bank transfer and certified cheque. All our prices are in dirhams, VAT included.
Can I get an invoice in my company's name (with its ICE)?
Yes. Provide your company's legal name and ICE when ordering: the invoice is issued in its name and enclosed with the parcel (handed over with the order for in-store collection). Companies and public bodies can also request a quote — reply within 24 working hours.
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
65 999 DHincl. VAT65 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.