As many watts as kVA: all 10 kW are usable, with no loss from the power factor. Ten outlets, all battery-backed, and the Web/SNMP management card included.
10 kW usable output (power factor of 1)
6 C13 outlets, the format used by computer and server power cords, all battery-backed
4 C19 outlets, heavy-duty 16 A, also battery-backed
Terminal block output also backed by the battery
Web/SNMP management card included to monitor the UPS remotely
USB, RJ-45 serial, RJ-45 network ports and SmartSlot
Internal bypass, automatic and manual
Full recharge in 1 h 30
Multifunction LCD status and control console
Temperature probe included
Emergency power off switch
Single-phase 230 V or three-phase 400 V input depending on the installation
Sine wave output
55 dB noise level, to be installed in a technical room
A high-power online UPS for critical infrastructure: online double conversion, 10 kW / 10 kVA. Technology & protection: power is constantly rebuilt — the equipment receives flawless power without ever touching the mains, with zero transfer time. Maximum protection against outages, surges, voltage fluctuations and electrical noise. Power: 10 kVA for 10 kW of real power (power factor of 1) — all of the rated power is available in watts, enough for a full server rack. Outlets: 6 C13 outlets + 4 heavy-duty C19 outlets + terminal block connection. Pure sine wave output; active cooling (≈ 55 dB), to be installed in a technical room. LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Designed, for example, for server racks, data centres and critical infrastructure. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Does this 10 kVA UPS really deliver 10 kW?
Yes: its power factor is 1, so the full 10,000 VA is available in watts. On a UPS with a 0.8 power factor, only 8000 would remain — that is 2000 W less equipment for the same footprint.
Does the SRT10KXLI accept single-phase or three-phase input?
Both: fixed connection as 3-wire single-phase (230 V) or 5-wire three-phase (400 V), depending on the installation. In both cases it is fixed wiring, with no plug, to be done by an electrician.
Are all the SRT10KXLI's outputs battery-backed?
Yes, all of them: six C13 outlets, four heavy-duty C19 outlets, three IEC jumpers and the 3-wire terminal block output are all powered by the battery. No output is limited to surge protection only.
Is the network management card included?
Yes, a Web/SNMP management card is supplied — which is rare, as it is almost always sold separately. It comes with a temperature probe, so you can monitor the room temperature from the same interface.
How long does it take to recharge the batteries after an outage?
1 hour 30 minutes for a full recharge — remarkably fast for this power rating. This shortens the window during which a second outage would find you with no reserve.
How much space does the SRT10KXLI take up, and how much does it weigh?
26.3 cm wide, 71.5 cm deep and 43.2 cm high, weighing 111.8 kg — 126.8 kg with packaging. The weight and access to the room are the two points to sort out even before the wiring.
Can you work on the UPS without powering down the racks?
Yes, thanks to its automatic and manual internal bypass, and conversely an emergency power off switch lets you cut everything in one move. The surge protector absorbs 480 joules.
What battery does the SRT10KXLI use, and how is it replaced?
A sealed, maintenance-free lead-acid battery with suspended electrolyte, whose replacement part number is APCRBC140. The internal battery is covered for two years.
Is the APC Smart-UPS SRT SRT10KXLI new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 3 years. It delivers a sine wave output, accepts an input of 160 to 275 V between 40 and 70 Hz, and stays below 55 dBA: it belongs in a technical room. The datasheet covers the rest.
Network management card already fitted, with environmental monitoring: it is administered and raises alerts remotely. 9 minutes of runtime at 50% load (10 kW), extendable with battery packs.
•Runtime: 9 min at 50% load (10 kW), 5 min at 70% (14 kW)
•An external battery pack is included; runtime remains extendable
•Network Management Card 3 pre-installed, with environmental monitoring
A 15 kVA / 15 kW double-conversion online three-phase UPS with internal batteries, for a technical room or a small server room. It lasts 33 minutes at half load, accepts an additional battery module and can be paralleled up to four units.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Three-phase online UPS rated 20 kVA for 20 kW, configurable as 3:3, 3:1 or 1:1. Supplied without batteries: 32 to 40 12 V blocks inside, or external cabinets. Up to 98.5% efficiency in ECO mode, maintenance bypass and touch screen.
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
•8 C13 + 2 C19 outlets + hardwired output
•Hardwired input on terminal block
•15 kVA / 15 kW, double-conversion online
•400 V three-phase input and output
•33 min at half load, 12.5 min at full load
In stock
71 399 DHincl. VAT71 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•20 kVA / 20 kW: output power factor 1.0
•Three-phase or single-phase: 3:3, 3:1 or 1:1 configurations
•Online double conversion, zero transfer time
In stock
52 200 DHincl. VAT52 200,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
47 999 DHincl. VAT47 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
6 C13 outlets, the format used by computer and server power cords, all battery-backed
In stock
47 999 DHincl. VAT47 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
In stock
35 299 DHincl. VAT35 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 5 minutes at 70% load (7000 W)
•3-wire terminal block connection: fixed wiring, to be installed by an electrician
In stock
28 599 DHincl. VAT28 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.