Around 8 minutes of runtime at half load (3,000 W) and 6,000 W genuinely available, with no loss from the power factor. Full recharge in 1 h 30, in a chassis only 17 cm wide.
6,000 W usable output (power factor of 1)
Around 8 minutes of runtime at 50% load (3,000 W), 5 minutes at 70% (4,200 W)
6 C13 outlets, the format used by computer and server power cords, all battery-backed
4 C19 outlets, heavy-duty 16 A, also battery-backed
Terminal block output also backed by the battery
Web/SNMP management card included to monitor the UPS remotely
USB, RJ-45 serial, RJ-45 network ports and SmartSlot
Internal bypass, automatic and manual
Full recharge in 1 h 30
Multifunction LCD status and control console
Temperature probe included
Emergency power off switch
Sine wave output
55 dB noise level, to be installed in a technical room
A high-power online UPS for critical infrastructure: online double conversion, 6000 VA / 6000 W. Technology & protection: power is constantly rebuilt — the equipment receives flawless power without ever touching the mains, with zero transfer time. Maximum protection against outages, surges, voltage fluctuations and electrical noise. Power: 6000 VA for 6000 W of real power (power factor of 1) — all of the rated power is available in watts. Outlets: 6 C13 outlets + 4 heavy-duty C19 outlets + terminal block connection. Active cooling (≈ 55 dB), to be installed in a technical room. LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Designed, for example, for server racks, data centres and critical infrastructure. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Does this 6 kVA UPS really deliver 6000 W?
Yes, its power factor is 1: the full 6000 VA is available in watts. On a UPS with a 0.8 power factor, only 4800 would remain — that is 1200 W less equipment for the same footprint.
How long does the SRT6KXLI run on battery?
8 minutes at 50% load, i.e. 3000 W, and 5 minutes at 70%, i.e. 4200 W. A full recharge, on the other hand, is very fast: 1 hour 30 minutes, which reduces vulnerability between two outages in quick succession.
Is the network management card included with the SRT6KXLI?
Yes, a Web/SNMP management card is supplied in the box — which is rare, as it is almost always sold separately. The UPS also has an RJ-45 10/100 Base-T port, an RJ-45 serial port, a USB port, a contact closure and a SmartSlot.
Are all the SRT6KXLI's outputs battery-backed?
Yes, all of them: six C13 outlets, four heavy-duty C19 outlets, two IEC jumpers and even the 3-wire terminal block output are powered by the battery. No output is reserved for surge protection alone.
How is the SRT6KXLI connected to the electrical installation?
Via a 3-wire fixed connection — phase, neutral and earth: there is no plug to connect. The wiring must be done by an electrician, with a dedicated circuit to be provided at the distribution board before delivery.
How much space does the SRT6KXLI take up, and how much does it weigh?
Only 17.4 cm wide, for 71.9 cm deep and 43.2 cm high, and 60 kg. It is a narrow but long and heavy tower unit: check the available depth and plan for two people.
What is in the SRT6KXLI box?
The Web/SNMP management card, a temperature probe, removable feet, a USB cable, the software CD, the documentation CD, the installation guide and the warranty card. The probe lets you monitor the room temperature from the monitoring system.
What battery does the SRT6KXLI use, and how is it replaced?
A sealed, maintenance-free lead-acid battery with suspended electrolyte, whose replacement part number is APCRBC140. The internal battery is covered for two years.
Can you work on the UPS without powering down the racks?
Yes, thanks to its automatic and manual internal bypass, and conversely an emergency power off switch lets you cut everything in one move. The surge protector also absorbs 480 joules.
Is the APC Smart-UPS SRT SRT6KXLI new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 3 years. It delivers a sine wave output, accepts an input of 160 to 275 V between 40 and 70 Hz, and stays below 55 dBA — it belongs in a technical room. The datasheet covers the rest.
A 15 kVA / 15 kW double-conversion online three-phase UPS with internal batteries, for a technical room or a small server room. It lasts 33 minutes at half load, accepts an additional battery module and can be paralleled up to four units.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Three-phase online UPS rated 20 kVA for 20 kW, configurable as 3:3, 3:1 or 1:1. Supplied without batteries: 32 to 40 12 V blocks inside, or external cabinets. Up to 98.5% efficiency in ECO mode, maintenance bypass and touch screen.
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
Network management card already fitted, with environmental monitoring: it is administered and raises alerts remotely. 9 minutes of runtime at 50% load (10 kW), extendable with battery packs.
•Runtime: 9 min at 50% load (10 kW), 5 min at 70% (14 kW)
•
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•20 kVA / 20 kW: output power factor 1.0
•Three-phase or single-phase: 3:3, 3:1 or 1:1 configurations
•Online double conversion, zero transfer time
In stock
52 200 DHincl. VAT52 200,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
47 999 DHincl. VAT47 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
35 299 DHincl. VAT35 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 8.5 min at half load, 3 min at full load
In stock
33 255,36 DHincl. VAT33 255,36 DHincl. VAT
Delivery everywhereDelivered all over Morocco
An external battery pack is included; runtime remains extendable
•Network Management Card 3 pre-installed, with environmental monitoring
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime 8.5 min at half load, 3 min at full load
In stock
33 255,36 DHincl. VAT33 255,36 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime 11 minutes at half load (3000 W)
•Runtime 7 minutes at 70% load (4200 W)
•Height 4U in a rack
In stock
25 599 DHincl. VAT25 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 7 minutes at 70% load (4200 W)
•Tower format, floor-standing
In stock
17 399 DHincl. VAT17 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard