Eaton 9PX 2200 VA Online UPS - RT2U (9PX2200IRT2U)
Under 40 dB: quiet enough to stay in an office. A power factor of 1, so 2,200 W genuinely available, and around 15 minutes of runtime at half load (1,100 W).
2,200 W usable output (power factor of 1)
Around 15 minutes of runtime at half load (1,100 W)
8 C13 outlets, the format used by computer and server power cords
2 C19 outlets, heavy-duty 16 A for power-hungry equipment
2 controllable outlet groups: the non-essential load is shed first
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP network card, remote monitoring
Multilingual graphic LCD display
Runtime extendable with additional battery modules, hot-swappable
Internal bypass: power still flows if the UPS develops a fault
Plugs into a 16 A C20 socket, input cable included
A high-end online UPS, convertible between rack and tower: online double conversion, 2200 VA / 2200 W, 2U format. Technology & protection: power is fully and continuously regenerated — your servers are never exposed to the mains, with zero transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 2200 VA for 2200 W of real power — its power factor of 1 makes all of the rated power available in watts. Runtime: about 15 minutes at half load (1100 W); extendable with additional battery modules. Outlets: 8 C13 outlets + 2 heavy-duty C19 outlets for power-hungry equipment. Management: USB port and RS-232 serial port for automatic shutdown; slot for an SNMP network card. Graphical LCD display to monitor the UPS. Low-noise operation (under 40 dB). Ideal, for example, for servers, storage or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
176 - 276 V without derating (up to 100 - 276 V with derating)
Battery replacement
User-replaceable, hot-swappable (no power interruption)
Battery management
ABM® or temperature-compensated charging method (user-selectable), automatic battery test, deep discharge protection, automatic recognition of external batteries
Interface port
1 USB port, 1 RS232 serial port, 1 remote ON/OFF mini terminal block, 1 remote power-off mini terminal block, 1 output relay mini terminal block
User interface
Multilingual graphic LCD display
Audible alarm
Yes
Power management software
Eaton Intelligent Power
Weight (kg)
25 kg
Dimensions (W x D x H) (mm)
440 x 605 x 86.5 mm
Technology
On-line
Power (VA)
2,200 VA
Voltage stabiliser
Yes
Box contents
9PX uninterruptible power supply
Input cable
2 IEC output power cords
USB cable
Serial cable
2 brackets for 19-inch mounting
2 universal rails
2 brackets for tower mounting
Cable locking systems
Safety guide
Quick start
Technical specifications (continued)
Communication card slot
1 slot for Network-MS, ModBus-MS or Relay-MS card (optional)
Rack height
2U
Transfer/switching time
0 ms (continuous double conversion)
Bypass
Internal bypass
Audible noise
< 40 dBA
Power factor (ratio)
1
Input power factor
Input power factor correction (PFC), ratio not published by the manufacturer
Output frequency
50 - 60 Hz
Phase (output/input)
Single-phase / Single-phase
Eco mode efficiency
98% in high-efficiency mode
Double-conversion efficiency
Up to 93% in online mode
Output type
C13 outlets
Power (W)
2,200 W
Runtime
43 min at 300 W; 25 min at 500 W; 15 min at 800 W; 9 min at 1,200 W; 5 min at 1,800 W
External battery packs
Up to 4 hot-swappable external battery modules (EBM 9PXEBM72RT2U)
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the 9PX 2200 run on battery?
15 minutes at half load, i.e. 1100 W. That is comfortable for a 2200 VA unit, and runtime can be extended with additional hot-swappable battery modules.
Does this 2200 VA UPS really deliver 2200 W?
Yes: the power factor is 1, so the full 2200 VA is available in watts. On a line-interactive UPS with a 0.6 power factor, only 1320 would remain — almost 900 W less equipment.
Can a 2200 VA online UPS stay in an office?
This one, yes: it is rated at less than 40 dBA, which is very low for a double-conversion unit of this power. That is what allows it to sit in an occupied room rather than in a technical room.
How does the 9PX 2200 plug into the mains?
Into a 16 A C20 connection, with the input cable supplied. Note: this is the heavy-duty format, not the C14 of a desktop UPS — the wall socket must be able to deliver the corresponding current.
What are the controllable outlet groups on the 9PX 2200 for?
To cut non-essential loads first: two groups can be controlled separately, so you can reserve the battery for critical machines during an outage. That is extra runtime with no additional hardware.
What outlets does the 9PX 2200 have?
Eight C13 outlets and two heavy-duty 16 A C19 outlets. Two IEC output cords are supplied: beyond two machines, you will need your own cords.
Can the 9PX 2200 be installed in a rack or as a tower?
Both, and everything is supplied: two 19-inch mounting brackets, two universal rails and two tower stands. Allow for 2U, 440 mm wide, 605 mm deep and 25 kg.
Does power still get through if the UPS fails?
Yes, an internal bypass lets mains power through to the equipment. The UPS also accepts an input of 176 to 276 V between 40 and 70 Hz before drawing on its battery.
Is the Eaton 9PX 2200 (9PX2200IRT2U) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It delivers a sine wave output, shows its status on a multilingual graphic LCD screen, and has a slot for a Network-MS, ModBus-MS or Relay-MS card. The datasheet covers the rest.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
A 1500 VA / 1500 W Smart-UPS SRT online UPS in 2U rack format, delivered with its NMC 3 network management card and rails. Pure sine wave output, six C13 outlets in two controllable groups, swappable battery and runtime expandable with external packs.
A 6000 VA / 6000 W double-conversion online UPS delivered complete: 2U power module, 3U SRV240RLBP-9A external battery pack and rail kit. Terminal-block connection, pure sine wave output, 94 % efficiency and runtime expandable up to four packs.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
•Runtime 9 minutes at 50% load (5000 W)
•
•1500 VA / 1500 W, double-conversion online
•NMC 3 network card pre-installed
•6 C13 outlets in 2 controllable groups
In stock
23 399 DHincl. VAT23 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•6000 VA / 6000 W, double-conversion online
•5U rack: 2U UPS and 3U battery pack
•SRV240RLBP-9A battery pack supplied
In stock
24 299 DHincl. VAT24 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Built-in network card to monitor and control the UPS remotely
•1980 W genuinely available
•8 C13 outlets, the format of computer and server power cords
In stock
25 399 DHincl. VAT25 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 11 minutes at half load (3000 W)
•Runtime 7 minutes at 70% load (4200 W)
•Height 4U in a rack
In stock
25 599 DHincl. VAT25 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 7 minutes at 70% load (4200 W)
•Tower format, floor-standing
In stock
17 399 DHincl. VAT17 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime with the 16 internal batteries: 9 min at 50% load, 23 min at 25%
•With an additional battery cabinet: 23 min at 50% load, 60 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
In stock
16 299 DHincl. VAT16 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 5 minutes at 70% load (7000 W)
•3-wire terminal block connection: fixed wiring, to be installed by an electrician
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
10 399 DHincl. VAT10 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
6 C13 outlets, the format used by computer and server power cords, all battery-backed