A whole server rack on a single unit: 10,000 W genuinely available, as many as the stated VA. Web/SNMP management card included, three-phase 400 V connection possible and output on outlets or on a terminal block.
10,000 W genuinely available, power factor of 1
Web/SNMP management card included, for remote monitoring
Input connection in 230 V single-phase or 400 V three-phase, on a terminal block
6 C13 outlets, the format used by computer and server power cords
4 C19 outlets, heavy-duty 16 A for power-hungry equipment
Output also available as terminal block wiring, to be installed by an electrician
Pure sine wave output
Automatic and manual internal bypass
Runtime extendable with additional SRT192RMBP2 battery packs
LCD display: load, battery level and remaining runtime at a glance
Temperature probe included
Full recharge in 1 h 30
Emergency power off switch
6U rack format, 111.82 kg
55 dBA noise level: active ventilation, to be installed in a technical room
A high-power online UPS for server rooms: online double-conversion technology, 10 kW / 10 kVA, rack format. Technology & protection: power is constantly rebuilt — the equipment receives flawless power without ever touching the mains, with zero transfer time. Maximum protection against outages, surges, voltage fluctuations and electrical noise. Power: 10 kVA for 10 kW of real power (power factor of 1) — all of the rated power is available in watts, enough to run a full server rack. Outlets: 6 C13 outlets + 4 heavy-duty C19 outlets for power-hungry equipment. Active cooling — best installed in a rack or technical room rather than on a desk. Designed, for example, for network racks and servers. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Does this 10 kVA unit really deliver 10,000 W?
Yes: its power factor is 1, so the full 10,000 VA is available in watts. That is what makes it possible to power an entire server rack from a single unit.
Does the SRT10KRMXLI accept a three-phase input?
Yes: it is connected via a terminal block, in 230 V single-phase or 400 V three-phase, depending on the installation. In both cases it is a hardwired connection, to be installed by an electrician.
Is the network management card supplied?
Yes, a Web/SNMP management card is supplied, together with a temperature probe to monitor the room from the same interface. Nothing extra to order to control the UPS remotely.
What outputs does the SRT10KRMXLI offer?
Six C13 outlets, four heavy-duty 16 A C19 outlets, three IEC jumpers, and optional hardwired terminal-block output for fixed distribution installed by an electrician.
How much rack space does the SRT10KRMXLI take up?
6U high, for 111.8 kg. At this weight, installation requires handling equipment and a checked floor; the unit goes at the bottom of the cabinet.
How long does it take to recharge the batteries?
1 h 30 for a full recharge — very fast for this power rating. The runtime can still be extended with SRT192RMBP2 additional battery packs.
Can the UPS be serviced without shutting down the rack?
Yes, thanks to an automatic and manual internal bypass. Conversely, an emergency power off switch lets you cut everything in one move, as the regulations for a technical room often require.
Is the APC Smart-UPS SRT SRT10KRMXLI new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for a period of 3 years. It delivers a pure sine wave and runs at 55 dBA: fan-cooled, to be installed in a technical room. The datasheet covers the rest.
Fifteen minutes of runtime at full load, internal batteries included. Dust filter and conformal-coated boards: it is made for demanding premises, on a three-phase 400 V input tolerated from 304 to 477 V.
•Runtime: around 15 minutes at full load (20 kW)
•Internal batteries included: 2 strings of 7 Ah, expandable to 3 for more runtime
•Three-phase 400 V input and output, also 380 or 415 V
Network management card already fitted, with environmental monitoring: it is administered and raises alerts remotely. 9 minutes of runtime at 50% load (10 kW), extendable with battery packs.
•Runtime: 9 min at 50% load (10 kW), 5 min at 70% (14 kW)
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
An external battery pack is included; runtime remains extendable
•Network Management Card 3 pre-installed, with environmental monitoring
In stock
129 399 DHincl. VAT129 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
65 999 DHincl. VAT65 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
In stock
51 199 DHincl. VAT51 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
49 999 DHincl. VAT49 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
•4 C19 outlets, heavy-duty 16 A, also battery-backed
Network management card already fitted, with environmental monitoring: it is administered and raises alerts remotely. 9 minutes of runtime at 50% load (10 kW), extendable with battery packs.
•Runtime: 9 min at 50% load (10 kW), 5 min at 70% (14 kW)
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
16 kW genuinely available and around 14 minutes of runtime at half load, extendable with up to four battery cabinets. Terminal block input and output, for hard-wired infrastructure.
•16 kW usable output
•Around 14 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.