nJoy Echo Pro 2000 Online UPS - 1600 W / 2000 VA - 4 FR outlets (UPOL-OL200EP-CG)
Seven minutes of runtime at half load (800 W) and under 40 dB: it sits below a desk without being heard. Over USB, it cleanly shuts down a Synology NAS or a server before the battery runs out.
Runtime: 7 min at 50% load (800 W), 17 min at 25%
Schuko outlets: an everyday device plugs straight in, with no adapter
Automatic shutdown of the NAS or the server over USB HID, compatible with Synology NAS units
RS-232, EPO and SNMP ports for monitoring and emergency shutdown
PowerGuide and PowerMaster software for monitoring
Pure sine wave output
LCD screen: load, battery level and faults
Input voltage accepted from 80 to 300 V
Input surge protection: 590 joules
Full protection against input surges
Automatic restart and recharge when the power returns
Online UPS to protect servers or sensitive equipment: online double-conversion, 2000 VA / 1600 W. Technology & protection: power is fully regenerated, continuously — your servers never touch the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 2000 VA for 1600 W of usable power — its excellent power factor puts almost all of the rated power to work in watts. Outlets: 4 Schuko outlets (earthed household sockets) — plug your devices in directly, no adapter needed. LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Ideal, for example, for a server, a demanding workstation or critical network equipment. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the Echo Pro 2000 last on battery?
7 minutes at 50% load, i.e. 800 W, and 17 minutes at 25%. Recharging then brings the battery back to 90% in 4 hours. In other words, halving the load more than doubles the runtime.
What input voltage does the Echo Pro 2000 accept?
From 80 to 300 V — an exceptionally wide window. On a grid that regularly dips to low voltage, the UPS keeps regenerating the power instead of switching to battery and draining it in a few cycles.
Can you choose the Echo Pro 2000's output voltage?
Yes: 208, 220, 230 or 240 V, as chosen by the user, with the output frequency held at 50 or 60 Hz within ±0.5 Hz. This setting is made once at installation, according to the voltage your equipment expects.
Can the Echo Pro 2000 shut down a Synology NAS on its own?
Yes, Synology NAS compatibility is stated: connected via USB HID, the NAS detects the outage and cleanly unmounts its volumes before the battery runs out. This is what avoids a volume rebuild on restart.
How much surge energy does the Echo Pro 2000 absorb?
590 joules on its mains input — well above average for UPSs of this size. Input surge protection is complemented by protection against surges inside the unit itself.
Why does 2000 VA give only 1600 W?
The output power factor is 0.8: 1600 W actually available, which is still well above the 0.6 of an entry-level UPS. On the input side, the power factor reaches 0.99: the UPS puts virtually no pollution back onto the upstream grid.
Can a 2000 VA online UPS fit under a desk?
Yes: it is rated at less than 40 dB in a tower case measuring 390 × 151 × 225 mm and weighing 16.6 kg. That is very quiet for a double-conversion unit: it does not require a dedicated technical room.
Can the Echo Pro 2000 be used with a generator?
Yes, generator compatibility is stated. Combined with the 80 to 300 V input range, this makes it a solid choice where the grid often cuts out and a generator takes over.
What efficiency does the Echo Pro 2000 reach, and with which batteries?
Up to 96% in ECO mode, with four internal GP07122L batteries. ECO mode saves energy by lightening the power conditioning: keep it for periods when the grid is clean.
Can two Echo Pro 2000 units be combined to double the power?
No, parallel operation is not supported on this model. For more power, you need to move up to a higher-capacity UPS — the Echo Pro also comes in a 3000 VA version.
Is the nJoy Echo Pro 2000 UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 3 years. It restarts and recharges automatically when power returns, and shows its status on an LCD screen. The datasheet covers the rest.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Runtime: 6 min at 50% load (400 W), 19 min at 25%
•Schuko outlets: an everyday device plugs straight in, with no adapter
•Automatic NAS or server shutdown over USB HID, compatible with Synology NAS units
In stock
2 795 DHincl. VAT2 795,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
8 799 DHincl. VAT8 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
9 199 DHincl. VAT9 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
•Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.