Seven minutes of runtime at half load (800 W) and under 40 dB: it sits below a desk without being heard. Over USB, it cleanly shuts down a Synology NAS or a server before the battery runs out.
Runtime: 7 min at 50% load (800 W), 17 min at 25%
Schuko outlets: an everyday device plugs straight in, with no adapter
Automatic shutdown of the NAS or the server over USB HID, compatible with Synology NAS units
RS-232, EPO and SNMP ports for monitoring and emergency shutdown
PowerGuide and PowerMaster software for monitoring
Pure sine wave output
LCD screen: load, battery level and faults
Input voltage accepted from 80 to 300 V
Input surge protection: 590 joules
Full protection against input surges
Automatic restart and recharge when the power returns
Online UPS to protect servers or sensitive equipment: online double-conversion, 2000 VA / 1600 W. Technology & protection: power is fully regenerated, continuously — your servers never touch the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 2000 VA for 1600 W of usable power — its excellent power factor puts almost all of the rated power to work in watts. Outlets: 4 Schuko outlets (earthed household sockets) — plug your devices in directly, no adapter needed. LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Ideal, for example, for a server, a demanding workstation or critical network equipment. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the Echo Pro 2000 last on battery?
7 minutes at 50% load, i.e. 800 W, and 17 minutes at 25%. Recharging then brings the battery back to 90% in 4 hours. In other words, halving the load more than doubles the runtime.
What input voltage does the Echo Pro 2000 accept?
From 80 to 300 V — an exceptionally wide window. On a grid that regularly dips to low voltage, the UPS keeps regenerating the power instead of switching to battery and draining it in a few cycles.
Can you choose the Echo Pro 2000's output voltage?
Yes: 208, 220, 230 or 240 V, as chosen by the user, with the output frequency held at 50 or 60 Hz within ±0.5 Hz. This setting is made once at installation, according to the voltage your equipment expects.
Can the Echo Pro 2000 shut down a Synology NAS on its own?
Yes, Synology NAS compatibility is stated: connected via USB HID, the NAS detects the outage and cleanly unmounts its volumes before the battery runs out. This is what avoids a volume rebuild on restart.
How much surge energy does the Echo Pro 2000 absorb?
590 joules on its mains input — well above average for UPSs of this size. Input surge protection is complemented by protection against surges inside the unit itself.
Why does 2000 VA give only 1600 W?
The output power factor is 0.8: 1600 W actually available, which is still well above the 0.6 of an entry-level UPS. On the input side, the power factor reaches 0.99: the UPS puts virtually no pollution back onto the upstream grid.
Can a 2000 VA online UPS fit under a desk?
Yes: it is rated at less than 40 dB in a tower case measuring 390 × 151 × 225 mm and weighing 16.6 kg. That is very quiet for a double-conversion unit: it does not require a dedicated technical room.
Can the Echo Pro 2000 be used with a generator?
Yes, generator compatibility is stated. Combined with the 80 to 300 V input range, this makes it a solid choice where the grid often cuts out and a generator takes over.
What efficiency does the Echo Pro 2000 reach, and with which batteries?
Up to 96% in ECO mode, with four internal GP07122L batteries. ECO mode saves energy by lightening the power conditioning: keep it for periods when the grid is clean.
Can two Echo Pro 2000 units be combined to double the power?
No, parallel operation is not supported on this model. For more power, you need to move up to a higher-capacity UPS — the Echo Pro also comes in a 3000 VA version.
Is the nJoy Echo Pro 2000 UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 3 years. It restarts and recharges automatically when power returns, and shows its status on an LCD screen. The datasheet covers the rest.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
An online double-conversion 2U rack or tower UPS for a network rack: 900 W of pure sine wave power, hot-swappable batteries, runtime extendable with an external pack and rail kit included.
Short 438 mm depth for small racks: power continuously regenerated with zero transfer time, 4 C13 outlets, hot-swappable batteries and automatic server shutdown over USB or RS232.
An online double-conversion tower UPS for a server or a small rack: 1800 W of pure sine wave power, no transfer time, 13 minutes at half load and an input tolerated from 80 to 280 V.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
•Runtime: 13 min at half load, 4.5 min at full load
In stock
8 599 DHincl. VAT8 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.
•2000 VA / 1800 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
10 308 DHincl. VAT10 308,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
10 399 DHincl. VAT10 399,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
•Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
A 1500 VA / 1500 W Smart-UPS SRT online UPS in 2U rack format, delivered with its NMC 3 network management card and rails. Pure sine wave output, six C13 outlets in two controllable groups, swappable battery and runtime expandable with external packs.
A 2000 VA / 1800 W double-conversion online UPS in 2U rack format, for a server, a NAS or the core of a network. Pure sine wave output, four C13 outlets, LCD screen, USB, RS-232 and a network card slot; the rails are ordered separately.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
6 C13 outlets, the format used by computer and server power cords, all battery-backed
In stock
47 999 DHincl. VAT47 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.