Eaton 9SX 5000i 5000 VA Online UPS - RT3U (9SX5KiRT)
4,500 W usable thanks to the 0.9 power factor, and around 13 minutes of runtime at 50% load (2,250 W): time enough to shut a rack down cleanly. The software included shuts the servers down on its own when the battery runs low.
Usable power of 4,500 W (0.9 power factor)
Runtime of around 13 minutes at 50% load (2,250 W), 10 minutes at 70%
8 C13 outlets, the format of computer and server power cords
2 C19 outlets, reinforced 16 A for power-hungry equipment
Output also available on a terminal block
2 controllable outlet groups: cut the non-essential first
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP network card, remote monitoring
Intelligent Power software included, compatible with VMware and Hyper-V
Internal bypass: power still flows even if the UPS develops a fault
Hot-swappable batteries from the front panel
Runtime extendable with external battery cabinets, detected automatically
Multilingual graphic LCD display, rotatable for rack or tower
High-end online UPS, convertible to rack or tower: online double-conversion, 5000 VA / 4500 W, 3U form factor. Technology & protection: power is fully regenerated, continuously — your servers never touch the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 5000 VA for 4500 W of usable power (power factor of 0.9) — almost all of the rated power is available in watts. Runtime: approx. 13 minutes at half load (2250 W), 10 minutes at 70%. Ports: 8 C13 outlets + 2 heavy-duty C19 outlets + terminal block. Active cooling (≈ 45 dB), best installed in a technical room. Designed, for example, for servers, storage or critical network racks. LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
How long does the 9SX 5000i last on battery?
13 minutes at 50% load, i.e. 2250 W, and 10 minutes at 70%, i.e. 3150 W. Runtime can be extended with hot-swappable external battery modules, which the UPS detects automatically.
What exactly is in the 9SX 5000i box?
The UPS, two IEC-IEC cords, two rack-mount kits, a cable locking system and the safety instructions. Rack mounting therefore requires no additional accessories.
Does this 5 kVA unit really deliver 4500 W of usable power?
Yes, thanks to its 0.9 power factor: 5000 × 0.9 = 4500 W. The 9SX also has built-in input power factor correction, which limits the harmonic pollution sent back onto the grid.
What outputs does the 9SX 5000i offer?
Eight C13 outlets, two heavy-duty C19 outlets and a terminal block output. The input is on a terminal block: fixed wiring, to be done by an electrician before commissioning.
Can some equipment be shut down before the rest during an outage?
Yes: two controllable outlet groups let you switch off non-essential equipment first and save the battery for critical machines. That is extra runtime gained with no additional hardware.
How do you cleanly shut down virtualised servers?
The Intelligent Power software is supplied and covers VMware and Hyper-V environments. It communicates with the UPS via the USB port or the RS-232 serial port — the two cannot be used at the same time.
Can the 9SX 5000i be installed in a rack or as a tower?
Both: a convertible 3U chassis measuring 440 × 130 × 685 mm and weighing 48 kg, with a multilingual graphic LCD screen that rotates to suit the chosen position. At this weight, rack mounting is a two-person job.
Does power keep flowing if the UPS develops a fault?
Yes, an internal bypass keeps the load supplied if the UPS fails or in the event of a downstream short circuit. The unit also measures its own energy consumption, which is shown on the screen.
Is the network management card included?
No: it is only included as standard on the Netpack versions. On this model, the slot is free and accepts a Network-MS (SNMP), ModBus-MS or Relay-MS dry-contact card, to be ordered separately.
Is the Eaton 9SX 5000i (9SX5KIRT) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 2 years. It delivers a sine wave, stays below 45 dB and has batteries that are hot-swappable from the front panel. The datasheet covers the rest.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
A free-standing tower on castors, with an LCD screen showing the load, the battery status and the voltages. Around 16 minutes of runtime at half load, extendable with up to four battery cabinets.
•Around 16 minutes of runtime at half load
•Runtime extendable with one to four external battery cabinets
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
A 6000 VA / 6000 W double-conversion online UPS delivered complete: 2U power module, 3U SRV240RLBP-9A external battery pack and rail kit. Terminal-block connection, pure sine wave output, 94 % efficiency and runtime expandable up to four packs.
•
Runtime 8.5 min at half load, 3 min at full load
In stock
33 255,36 DHincl. VAT33 255,36 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
•Internal bypass and maintenance bypass as standard
In stock
41 999 DHincl. VAT41 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 5 minutes at 70% load (7000 W)
•3-wire terminal block connection: fixed wiring, to be installed by an electrician
In stock
28 599 DHincl. VAT28 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Runtime 11 minutes at half load (3000 W)
•Runtime 7 minutes at 70% load (4200 W)
•Height 4U in a rack
In stock
25 599 DHincl. VAT25 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
Built-in network card to monitor and control the UPS remotely
•1980 W genuinely available
•8 C13 outlets, the format of computer and server power cords
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Built for the server room: 8 C13 outlets, 2 C19 and a hardwired output, 98% efficiency in eco mode and runtime expandable with external battery modules. Hot-swappable batteries, managed over USB, RS232 or an optional network card.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Online double-conversion UPS rated 6000 VA for 6000 W, with no internal battery: it runs on one to four external cabinets. With one 2U cabinet of 16 HR09122F batteries, it holds 17 min at half load and 5 min at full load.
A 6000 W online double-conversion UPS for a server fleet, a storage array or a network room: pure sine wave, power factor 1, up to 95.5% efficiency. Rack or tower, manual maintenance bypass, expandable runtime.
•6000 VA / 6000 W, online double conversion
•Output power factor 1: all 6 kVA usable in watts
•Pure sine wave, output voltage regulated to ± 1%
In stock
25 416 DHincl. VAT25 416,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•3 C19 outlets: reinforced 16 A outlets for power-hungry equipment
•Terminal block input: fixed wiring, to be installed by an electrician
In stock
39 099 DHincl. VAT39 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
4 C19 outlets, heavy-duty 16 A, also battery-backed
In stock
61 799 DHincl. VAT61 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime 8.5 min at half load, 3 min at full load
In stock
33 255,36 DHincl. VAT33 255,36 DHincl. VAT
Delivery everywhereDelivered all over Morocco
The most powerful Amplon RT: 2700 W of pure sine wave power, in 2U rack or tower, for several servers or a storage rack. Hot-swappable batteries, extendable runtime and efficiency up to 94%.
•3000 VA / 2700 W, online double conversion
•2U rack or tower, brackets and rail kit included
•Pure sine wave, zero transfer time
In stock
13 062 DHincl. VAT13 062,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime extendable with one to four external battery cabinets
•Internal bypass and maintenance bypass as standard
In stock
21 199 DHincl. VAT21 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
In stock
18 199 DHincl. VAT18 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•
6000 VA / 6000 W: output power factor 1.0
•Online double conversion, zero transfer time
•External batteries only: 2U or 3U cabinet, up to 4
In stock
14 616 DHincl. VAT14 616,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
An online double-conversion 2U rack or tower UPS: 1800 W of pure sine wave power for a server and its rack, efficiency up to 94%, hot-swappable batteries and runtime extendable with an external pack.