A coating protects the circuits against dust, humidity and corrosive vapours: it holds up in a workshop or a warehouse. Around 10 minutes of runtime at half load (1350 W).
Runtime: 10 min at 50 % load (1350 W)
Schuko outlets: a standard device plugs in directly, with no adapter
Printed circuit boards coated against dust, humidity and corrosive products
Pure sine wave output
Automatic shutdown of the NAS or the server over USB HID
Smart port for an optional SNMP or WiFi card, remote monitoring
RS-232 port and ViewPower software for monitoring
Backlit graphic LCD screen, with fault log
Internal HR09122F fast-discharge batteries, designed for heavy loads
Input voltage accepted from 180 to 280 V at full load, from 120 V at half load
Cold start and internal bypass
Input power factor correction
Generator compatible
Efficiency up to 95 % in ECO mode
Tower format, 27.6 kg
Ref.: PWUP-OL300AP-AZ
Out of stock
1/5
5 899,00 DHincl. VAT
Out of stock
Product overview
Online UPS to protect servers or sensitive equipment: online double-conversion, 3000 VA / 2700 W. Technology & protection: power is fully regenerated, continuously — your equipment never touches the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 3000 VA for 2700 W of usable power (power factor of 0.9) — almost all of the rated power is available in watts. Outlets: 4 Schuko outlets (earthed household sockets) — plug your devices in directly, no adapter needed. LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Ideal, for example, for a server, a demanding workstation or critical network equipment. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
4 Schuko outlets with battery backup and surge protection
Input voltage
230 V
Input frequency
50 / 60 Hz
Input connections
(1) IEC-320 C14
Voltage range
120 - 300 V at 50% load; 180 - 280 V at 100% load
Battery type
Lead-acid, high energy density and high-rate discharge
Interface port
1 RS-232 port, 1 USB port, 1 intelligent port for SNMP card
User interface
Graphic LCD screen with colour backlight (status, diagnostics and log)
Power management software
ViewPower
Weight (kg)
27.6 kg
Dimensions (W x D x H) (mm)
190 x 421 x 318 mm
Technology
On-line
Power (VA)
3,000 VA
Voltage stabiliser
Yes
Preinstalled batteries
6
Replacement battery
nJoy HR09122F
Technical specifications (continued)
Communication card slot
1 intelligent port for SNMP or WEB card — card optional
Transfer/switching time
0 ms (continuous double conversion)
Cold start
Yes
Bypass
Internal bypass
Audible noise
< 50 dB
Power factor (ratio)
0.9
Output frequency
50 Hz or 60Hz ± 0.5 %
Phase (output/input)
Single-phase
Eco mode efficiency
Up to 95%
Double-conversion efficiency
88% on battery (double-conversion efficiency on mains not published by the manufacturer)
Output type
C13 outlets
Power (W)
2,700 W
Runtime
10 min at 50% load (1,350 W)
External battery packs
None (runtime not expandable)
Form factor
Tower
Battery-backed outlets
3 to 4 outlets
Control & communication
USB, RS232 serial port, Network (SNMP / monitoring)
Warranty
1 year
Customer reviews
No reviews yet
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
What makes the Aten PRO 3000 suitable for a dusty room?
Its circuit boards are conformal-coated: a coating protects the electronics against dust, humidity and corrosive fumes. This is what allows it to hold up in a workshop, a warehouse or a non-air-conditioned room, where an ordinary UPS deteriorates.
How long does the Aten PRO 3000 last on battery?
About 10 minutes at 50% load, i.e. 1350 W. Its internal batteries are high-rate discharge HR09122F units, designed to deliver a lot of energy over a short time — so for heavy loads rather than long outages.
What input voltage does the Aten PRO 3000 accept?
180 to 280 V at full load, and from 120 V at half load. These two ranges are not interchangeable: the more heavily the UPS is loaded, the narrower the tolerance. The input is also fitted with power factor correction.
Is the transfer time really zero?
Yes: the switchover from mains to the UPS happens instantly, with no interruption. The double-conversion architecture provides tight voltage and frequency regulation, and delivers a pure sine wave with no harmonic distortion or electrical noise.
Can the Aten PRO 3000 be used with a generator?
Yes: it compensates for both frequency and voltage fluctuations when connected to a generator, and keeps supplying clean power without interruption. A decisive point where the grid often cuts out.
What efficiency does the Aten PRO 3000 reach?
Up to 95% in eco mode, where the double-conversion stages are bypassed, and 88% in battery mode. Eco mode reduces power consumption, but also the heat given off — which extends the life of the internal batteries.
What does the Aten PRO 3000's display show?
A backlit colour graphic LCD screen shows the UPS status at a glance, and also provides diagnostic information and a log: enough to identify a power problem before it damages your equipment.
How do you monitor the Aten PRO 3000 remotely?
Through an intelligent slot that accepts an optional SNMP or Wi-Fi card, and through an RS-232 port with the ViewPower software. The USB HID port, for its part, is used for automatic shutdown of a NAS or server.
Why does 3000 VA give only 2700 W?
The power factor is 0.9: 3000 × 0.9 = 2700 W actually available — almost all of the apparent power. The output voltage can also be set to 200, 208, 220, 230 or 240 V.
How much space does the Aten PRO 3000 take up, and is it noisy?
421 × 190 × 318 mm and 27.6 kg, in a tower format with full front access. It is rated at less than 50 dB: reasonable for a 3000 VA double-conversion unit, but it stands on the floor, not on a piece of furniture.
Is the nJoy Aten PRO 3000 UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It features cold start and an internal bypass, and connects via a C14 inlet, with four Schuko outlets on the output.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
8 799 DHincl. VAT8 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime: 6 min at 50% load (400 W), 19 min at 25%
•Schuko outlets: an everyday device plugs straight in, with no adapter
•Automatic NAS or server shutdown over USB HID, compatible with Synology NAS units
In stock
2 795 DHincl. VAT2 795,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
9 199 DHincl. VAT9 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords