Eaton 9PX 3000 VA Online UPS - RT2U (9PX3000IRT2U)
As many watts as VA: the power factor of 1 makes 3000 W genuinely available, where a conventional UPS loses part of it. Ten output outlets, a graphic LCD display and a slot for a network management card.
3000 W genuinely available, power factor of 1
8 C13 outlets, the format used by computer and server power cords
2 C19 outlets, heavy-duty 16 A for power-hungry equipment
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP, Modbus or dry contact network card
Pure sine wave output
Multilingual graphic LCD display
Convertible: 2U rack or tower mounting, brackets included
Accepted input voltage from 176 to 276 V
Terminal block for remote start-up and shutdown
Noise level below 40 dBA
Weight 27.6 kg
Ref.: 9PX3000IRT2U
Out of stock
28 199,00 DHincl. VAT
Out of stock
Product overview
A high-end online UPS, convertible between rack and tower: online double conversion, 3000 VA / 3000 W, 2U format. Technology & protection: power is fully and continuously regenerated — your servers are never exposed to the mains, with zero transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 3000 VA for 3000 W of real power — its power factor of 1 makes all of the rated power available in watts. Outlets: 8 C13 outlets + 2 heavy-duty C19 outlets for power-hungry equipment. Management: USB port and RS-232 serial port for automatic shutdown; slot for an SNMP network card. Pure sine wave output; low-noise operation (under 40 dB). LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Ideal, for example, for servers, storage or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
176 - 276 V without derating (up to 100 - 276 V with derating)
Battery replacement
User-replaceable, hot-swappable (no power interruption)
Battery management
ABM® or temperature-compensated charging method (user-selectable), automatic battery test, deep discharge protection, automatic recognition of external batteries
Interface port
1 USB port, 1 RS232 serial port, 1 remote ON/OFF mini terminal block, 1 remote power-off mini terminal block, 1 output relay mini terminal block
User interface
Multilingual graphic LCD display
Audible alarm
Yes
Power management software
Eaton Intelligent Power
Weight (kg)
27.6 kg
Dimensions (W x D x H) (mm)
440 x 605 x 86.5 mm
Technology
On-line
Power (VA)
3,000 VA
Voltage stabiliser
Yes
Box contents
9PX uninterruptible power supply
Input cable
2 IEC output power cords
USB cable
Serial cable
2 brackets for 19-inch mounting
2 universal rails
2 brackets for tower mounting
Cable locking systems
Safety guide
Quick start
Technical specifications (continued)
Communication card slot
1 slot for Network-MS, ModBus-MS or Relay-MS card (optional)
Rack height
2U
Transfer/switching time
0 ms (continuous double conversion)
Bypass
Internal bypass
Audible noise
< 40 dBA
Power factor (ratio)
1
Input power factor
Input power factor correction (PFC), ratio not published by the manufacturer
Output frequency
50 - 60 Hz
Phase (output/input)
Single-phase / Single-phase
Eco mode efficiency
98% in high-efficiency mode
Double-conversion efficiency
Up to 94% in online mode
Output type
C13 outlets
Power (W)
3,000 W
Runtime
60 min at 300 W; 36 min at 500 W; 22 min at 800 W; 13 min at 1,200 W; 7 min at 1,800 W; 4 min at 2,500 W
External battery packs
Up to 4 hot-swappable external battery modules (EBM 9PXEBM72RT2U)
Form factor
Convertible rack/tower
Battery-backed outlets
9 outlets or more
Control & communication
USB, RS232 serial port, Card slot
Warranty
1 year
Customer reviews
No reviews yet
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Does this 9PX 3000 really deliver 3000 W?
Yes: the power factor is 1, so the full 3000 VA is available in watts. On a conventional UPS with a 0.7 power factor, only 2100 would remain — that is almost 900 W more equipment.
What outlets does the 9PX 3000 RT2U have?
Eight C13 outlets and two heavy-duty 16 A C19 outlets, with a C20 input. The input cable and two IEC output cords are supplied.
Can the 9PX 3000 RT2U be installed in a rack or as a tower?
Both, with the brackets supplied: two 19-inch mounting brackets, two universal rails and two stands for upright installation, plus a cable locking system. Allow for 2U and 605 mm of depth.
What voltage and frequency range does the 9PX 3000 accept?
From 176 to 276 V, over a frequency range of 40 to 70 Hz with automatic 50/60 Hz selection. This wide range lets it run behind an irregular power source without drawing on the battery.
Is the output of the 9PX 3000 a pure sine wave?
Yes, the output is a pure sine wave, continuously rebuilt by double conversion. That is what the power-factor-corrected power supplies in servers require.
How do you connect the 9PX 3000 to a monitoring system or a server?
Via a USB port, an RS-232 serial port and three mini terminal blocks — remote on/off, remote power off and output relay. A slot accepts a Network-MS, ModBus-MS or Relay-MS card.
Is a 3000 VA double-conversion UPS noisy?
This one stays below 40 dBA, which is low for this power rating and this topology. Allow for 27.6 kg: rack mounting takes two people, at the bottom of the cabinet.
Is the Eaton 9PX 3000 RT2U (9PX3000IRT2U) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It shows its status on a multilingual graphic LCD screen, and its battery runtime can be extended with an EBM 2U external module.
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
•
•
Built-in network card to monitor and control the UPS remotely
•1980 W genuinely available
•8 C13 outlets, the format of computer and server power cords
In stock
27 099 DHincl. VAT27 099,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
29 999 DHincl. VAT29 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 5 minutes at 70% load (7000 W)
•3-wire terminal block connection: fixed wiring, to be installed by an electrician
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.