Eaton 9PX 3000 VA Online UPS - RT3U (9PX3000IRT3U)
Ten output outlets, two of them heavy-duty 16 A for the most power-hungry equipment. 3000 W genuinely available thanks to the power factor of 1, a graphic LCD display and a slot for a network card.
3000 W genuinely available, power factor of 1
8 C13 outlets, the format used by computer and server power cords
2 C19 outlets, heavy-duty 16 A for power-hungry equipment
USB port and RS-232 serial port for automatic server shutdown
Slot for an SNMP, Modbus or dry contact network card
Pure sine wave output
Multilingual graphic LCD display
Shallow 3U format, tower-convertible, brackets included
Accepted input voltage from 176 to 276 V
Noise level below 40 dBA
Weight 27.4 kg
Ref.: 9PX3000IRT3U
Out of stock
1/2
25 399,00 DHincl. VAT
Out of stock
Product overview
A high-end online UPS, convertible between rack and tower: online double conversion, 3000 VA / 3000 W, 3U format. Technology & protection: power is fully and continuously regenerated — your servers are never exposed to the mains, with zero transfer time. Complete protection against outages, surges, voltage fluctuations and electrical noise. Power: 3000 VA for 3000 W of real power — its power factor of 1 makes all of the rated power available in watts. Outlets: 8 C13 outlets + 2 heavy-duty C19 outlets for power-hungry equipment. Management: USB port and RS-232 serial port for automatic shutdown; slot for an SNMP network card. Pure sine wave output; low-noise operation (under 40 dB). LCD display: shows load, battery level and remaining runtime at a glance — so you can monitor the UPS without any software. Ideal, for example, for servers, storage or network equipment. Remember to check how much power your equipment draws and to choose the rating according to the runtime you need.
176 - 276 V without derating (up to 100 - 276 V with derating)
Battery replacement
User-replaceable, hot-swappable (no power interruption)
Battery management
ABM® or temperature-compensated charging method (user-selectable), automatic battery test, deep discharge protection, automatic recognition of external batteries
Interface port
1 USB port, 1 RS232 serial port, 1 remote ON/OFF mini terminal block, 1 remote power-off mini terminal block, 1 output relay mini terminal block
User interface
Multilingual graphic LCD display
Audible alarm
Yes
Power management software
Eaton Intelligent Power
Weight (kg)
27.4 kg
Dimensions (W x D x H) (mm)
440 x 485 x 130 mm
Technology
On-line
Power (VA)
3,000 VA
Voltage stabiliser
Yes
Box contents
9PX uninterruptible power supply
Input cable
2 IEC output power cords
USB cable
Serial cable
2 brackets for 19-inch mounting
2 universal rails
2 brackets for tower mounting
Cable locking systems
Safety guide
Quick start
Technical specifications (continued)
Communication card slot
1 slot for Network-MS, ModBus-MS or Relay-MS card (optional)
Rack height
3U
Transfer/switching time
0 ms (continuous double conversion)
Bypass
Internal bypass
Audible noise
< 40 dBA
Power factor (ratio)
1
Input power factor
Input power factor correction (PFC), ratio not published by the manufacturer
Output frequency
50 - 60 Hz
Phase (output/input)
Single-phase / Single-phase
Eco mode efficiency
98% in high-efficiency mode
Double-conversion efficiency
Up to 94% in online mode
Output type
C13 outlets
Power (W)
3,000 W
Runtime
60 min at 300 W; 36 min at 500 W; 22 min at 800 W; 13 min at 1,200 W; 7 min at 1,800 W; 4 min at 2,500 W
External battery packs
Up to 4 hot-swappable external battery modules (EBM 9PXEBM72RT3U)
Form factor
Convertible rack/tower
Battery-backed outlets
9 outlets or more
Control & communication
USB, RS232 serial port, Card slot
Warranty
1 year
Customer reviews
No reviews yet
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Does this 3000 VA unit really deliver 3000 W?
Yes: the power factor is 1, so the full 3000 VA is available in watts. On a UPS at 0.7, only 2100 would be left — the difference lies in what the rack can actually carry.
What is the benefit of this 9PX's shallow 3U format?
It is only 485 mm deep, for 440 wide and 130 high, i.e. 3U. By trading one U of height for 12 cm less depth, it fits into shallow cabinets where a longer 2U unit will not.
Which outlets does the 9PX 3000 RT3U have?
Eight C13 outlets and two heavy-duty 16 A C19 outlets, with a C20 inlet. The input cable and two IEC output cords are supplied.
Can this 9PX 3000 stay in an occupied room?
It stays below 40 dBA, which is low for a 3000 VA double-conversion unit. Allow for 27.4 kg: rack installation takes two people, at the bottom of the cabinet.
What voltage range does the 9PX 3000 RT3U accept?
From 176 to 276 V, at a frequency of 50 or 60 Hz, auto-selected. The output can be set to 200, 208, 220, 230 or 240 V, depending on the voltage your equipment expects.
How do you monitor the 9PX 3000 RT3U?
Through a USB port, an RS-232 serial port and three mini terminal blocks — remote on/off, remote power off, relay output. A slot accepts a Network-MS, ModBus-MS or Relay-MS card, to be ordered separately.
Can the 9PX 3000 RT3U also be installed as a tower?
Yes, and the brackets are supplied: two 19-inch mounting brackets, two universal rails and two stands for vertical installation, plus a cable locking system.
Is the Eaton 9PX 3000 RT3U (9PX3000IRT3U) new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document. It delivers a pure sine wave, displays its status on a multilingual graphical LCD screen, and its battery can be extended with an external EBM 3U module.
Built-in network card: monitoring and control happen remotely, from the company network. 1980 W genuinely available and ten output sockets, two of them reinforced 16 A, in a chassis meant for the rack.
•Built-in network card to monitor and control the UPS remotely
•1980 W genuinely available
•8 C13 outlets, the format of computer and server power cords
Four U in a rack and a battery recharged in 3 hours: it is ready to go again quickly after a cut. Around 11 minutes of runtime at half load (3000 W) and 7 minutes at 70%.
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
•Runtime extendable with one to four external battery cabinets
A maintenance bypass supplied as standard allows the UPS to be replaced without shutting down the equipment it powers. Around 15 minutes of runtime at half load (4 000 W), extendable with four battery cabinets.
•Around 15 minutes of runtime at half load (4 000 W)
•Runtime extendable with one to four external battery cabinets
For a whole infrastructure: 9 minutes of runtime at half load (5000 W) and 5 minutes at 70%, the time it takes to switch over to a generator. 94% efficiency at full load and internal bypass.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
All the power available in watts: 10,000 W usable, as many as the VA. Around 7 minutes of runtime at half load (5000 W) to shut down a full rack cleanly, in only 4U.
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
•
Runtime 7 minutes at 70% load (4200 W)
•Height 4U in a rack
In stock
27 299 DHincl. VAT27 299,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
21 199 DHincl. VAT21 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Internal bypass and maintenance bypass as standard
In stock
29 999 DHincl. VAT29 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 5 minutes at 70% load (7000 W)
•3-wire terminal block connection: fixed wiring, to be installed by an electrician
In stock
30 599 DHincl. VAT30 599,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Around 11 minutes of runtime at 50% load (990 W), 7 minutes at 70% (1 386 W)
•All output outlets are battery-backed
•C13 outlets in the format used by computer and server power cords, C19 outlets heavy-duty at 16 A
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Three reinforced 16 A outlets for power-hungry hardware, eight server outlets, and batteries that are changed without cutting the power. Under 40 dB at one metre, in a rack as in a tower.
•8 C13 outlets: the format of computer and server power cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Twenty minutes of runtime at half load (2 400 W), extended to several hours with up to four external battery cabinets. The standard maintenance bypass allows the unit to be swapped without shutting down the equipment.
•Around 20 minutes of runtime at half load (2 400 W)
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.