nJoy Echo Pro 3000 Online UPS - 2400 W / 3000 VA - 4 FR outlets (UPOL-OL300EP-CG)
Alongside the direct outlets, a terminal block output allows a fixed circuit to be connected, fitted by an electrician. Around 7 minutes of runtime at half load (1200 W), below 40 dB.
Runtime: 7 min at 50% load (1200 W), 18 min at 25%
Schuko outlets: an everyday device plugs straight in, with no adapter
Additional terminal block output: fixed wiring, to be fitted by an electrician
Automatic shutdown of the NAS or the server over USB HID, compatible with Synology NAS units
RS-232, EPO and SNMP ports for monitoring and emergency shutdown
PowerGuide and PowerMaster software for monitoring
Pure sine wave output
LCD screen: load, battery level and faults
Input voltage accepted from 80 to 300 V
Input surge protection: 565 joules
Automatic restart and recharge when the power returns
Online UPS to protect servers or sensitive equipment: online double-conversion, 3000 VA / 2400 W. Technology & protection: power is fully regenerated, continuously — your servers never touch the mains, with no transfer time. Complete protection against power cuts, surges, voltage fluctuations and electrical noise. Power: 3000 VA for 2400 W of usable power — all of the power remains available for your critical equipment. Outlets: 4 Schuko outlets (earthed household sockets) — plug your devices in directly, no adapter needed. LCD display: shows load, battery level and remaining runtime at a glance — monitor the UPS without any software. Ideal, for example, for a server, a demanding workstation or critical network equipment. Remember to check how much power your equipment draws and to choose the capacity according to the runtime you need.
Be the first to review this product and help other customers.
Write a review
Frequently asked questions about this product
Does the Echo Pro 3000 have a terminal block output in addition to its outlets?
Yes, and that is what sets it apart: in addition to its four Schuko outlets, it offers a terminal block output for connecting a fixed circuit, installed by an electrician. You can therefore power both plug-in equipment and a dedicated line.
How long does the Echo Pro 3000 last on battery?
7 minutes at 50% load, i.e. 1200 W, and 18 minutes at 25%. On a 2400 W load, runtime is therefore counted in minutes: it is there to switch over to another source or to shut down cleanly, not to keep working through the outage.
What input voltage does the Echo Pro 3000 accept?
From 80 to 300 V. This very wide window lets it keep regenerating the power on a grid that regularly drops out, instead of switching to battery at every dip and draining it.
Why does 3000 VA give only 2400 W?
The power factor is 0.8: 3000 × 0.8 = 2400 W actually available — well above the 0.6 of an entry-level UPS, which would offer only 1800 for the same rated power.
Can the Echo Pro 3000 shut down a Synology NAS on its own?
Yes, Synology NAS compatibility is stated: connected via USB HID, the NAS detects the outage and unmounts its volumes before the battery runs out. The PowerGuide and PowerMaster software cover other systems.
Can a 3000 VA online UPS stay in an office?
This one, yes: it is rated at less than 40 dB, which is very low for a double-conversion unit of this power. On the other hand, allow for 416 × 196 × 342 mm and 21.3 kg: it stands on the floor, not on a piece of furniture.
How much surge energy does the Echo Pro 3000 absorb?
565 joules on its mains input. In double conversion, the power is continuously rebuilt anyway: this protection deals with the spikes that arrive before the conversion stage.
Can the Echo Pro 3000 be used with a generator?
Yes, generator compatibility is stated. Combined with the 80 to 300 V input range, this makes it a sensible choice where the grid often cuts out and a generator takes over.
What efficiency, and with how many batteries?
Up to 96% in ECO mode, with six internal GP07122L batteries. The UPS restarts and recharges automatically when power returns, with no intervention.
Can two Echo Pro 3000 units be combined to double the power?
No, parallel operation is not supported on this model. For more power, you need to move up the range; the terminal block output, on the other hand, lets you power a dedicated line in addition to the four outlets.
Is the nJoy Echo Pro 3000 UPS new and under warranty?
Yes, new equipment, with the invoice serving as the warranty document, for 3 years. It delivers a pure sine wave, shows its status on an LCD screen, and has RS-232, SNMP and EPO ports. The datasheet covers the rest.
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules
•C13 outlets: the format of computer and server power cords
Doubling the runtime comes down to one extra battery cabinet: 9 minutes at half load become 23 minutes. The 16 12 V batteries are chosen and ordered separately.
Floor-standing, 68.5 cm high and 54 kg: the tower version, for when there is no rack. Around 11 minutes of runtime at half load (3000 W) and 94% efficiency at full load.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
8 799 DHincl. VAT8 799,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
In stock
9 199 DHincl. VAT9 199,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
Runtime: 6 min at 50% load (400 W), 19 min at 25%
•Schuko outlets: an everyday device plugs straight in, with no adapter
•Automatic NAS or server shutdown over USB HID, compatible with Synology NAS units
In stock
2 795 DHincl. VAT2 795,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
9 999 DHincl. VAT9 999,00 DHincl. VAT
Delivery everywhereDelivered all over Morocco
•Runtime with the 16 internal batteries: 19 min at 50% load, 50 min at 25%, 6 min at full load
•With an additional battery cabinet: 50 min at 50% load, 115 min at 25%
•Batteries to be ordered separately: 16 12 V batteries of 7 or 9 Ah
26 minutes of runtime for 400 W drawn, 12 minutes at half load (800 W): ample time to save and shut down cleanly. The LCD display shows the load and the remaining runtime without any software.
•Runtime 12 minutes at half load (800 W)
•Runtime 26 minutes for 400 W drawn
•C13 outlets: the format of computer and server power cords
2400 W genuinely available and 13.5 minutes of battery life at half load (1200 W): time enough to save and shut down cleanly. Under 37 dB, it can stay beside the workstation it protects.
Every outlet is battery-backed, with around 11 minutes of runtime at half load (990 W). Automatic and manual internal bypass, LCD screen and a detachable 2.44 m cord supplied.
16 minutes of runtime at half load (800 W), and under 37 dB: it can sit next to a workstation without being heard. Its batteries are replaced without cutting the power.
•16 minutes of runtime at half load (800 W)
•7 minutes of runtime at full load
•6 C13 outlets, the format used by computer and server cords
Quiet at under 37 dB, it holds 11.5 minutes at half load (400 W): enough to save and shut down a NAS or a small server without losing anything. Its batteries are replaced without cutting the power.
•11.5 minutes of runtime at half load (400 W)
•5 minutes of runtime at full load
•4 C13 outlets, the format used by computer and server cords
Compatible with Synology NAS units over USB: the NAS shuts itself down cleanly when the battery runs low. Around 6 minutes of runtime at half load (400 W), for under 40 dB in operation.
Power factor of 1: all 8 000 W stated are available. Ten battery-backed outlets, four of them heavy-duty 16 A, and the Web/SNMP network management card is included.
•8 000 W usable output (power factor of 1)
•6 C13 outlets, the format used by computer and server power cords, all battery-backed
Ten battery-backed outlets, four of them heavy-duty 16 A, for 4 500 W usable and around 11 minutes of runtime at half load (2 250 W). The Web/SNMP management card is included.
•4 500 W usable output (power factor of 0.9)
•Around 11 minutes of runtime at 50% load (2 250 W), 7 minutes at 70% (3 150 W)
Nineteen minutes of runtime at half load, extended to fifty with an additional battery cabinet. The 16 12 V batteries are chosen and ordered separately.
Up to four external battery modules extend the 10.5 minutes of runtime at half load. The 2U rack mounting kit, the output cords and the USB cable are included.
•Runtime: 10.5 min at half load, 3.5 min at full load
•Runtime extendable by up to 4 external battery modules